Computed tomography measurement of the accuracy of component version in total hip arthroplasty

被引:144
作者
Wines, Andrew P.
McNicol, David
机构
[1] Childrens Hosp Westmead, Dept Orthopaed, Sydney, NSW 2145, Australia
[2] Royal N Shore Hosp, Dept Orthopaed, Sydney, NSW, Australia
[3] Calvary Hosp, Dept Orthopaed, Canberra, ACT, Australia
[4] Canberra Hosp, Dept Orthopaed, Canberra, ACT, Australia
关键词
hip; arthroplasty; component placement; measurement; CT scan;
D O I
10.1016/j.arth.2005.11.008
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The version of the acetabular and femoral components in 111 primary total hip arthroplasties was prospectively evaluated intra operatively by the surgeon and compared with postoperative computed tomography (CT) scan measurements. Intraoperative estimations by the surgeons for acetabular and femoral components were all within 10 degrees to 30 degrees anteversion, with means of 16.0 degrees (SD = 4.0 degrees) and 16.4 degrees (SD = 3.2\degrees), respectively. However, CT scan acetabular measurements ranged from 12 degrees retroversion to 52 degrees anteversion (mean = 22.0 degrees anteversion, SD = 14.0 degrees). Similarly, femoral component version ranged from -15 degrees retroversion to 450 anteversion (mean = 16.8 degrees anteversion, SD = 11.1 degrees). According to CT calculations, only 71% of femoral and 45% of acetabular components were within the expected clinical version range. In conclusion, the intraoperative estimation of acetabular and femoral version in a total hip arthroplasty is of limited accuracy.
引用
收藏
页码:696 / 701
页数:6
相关论文
共 20 条
  • [1] ANTEVERSION OF THE ACETABULAR CUP - MEASUREMENT OF ANGLE AFTER TOTAL HIP-REPLACEMENT
    ACKLAND, MK
    BOURNE, WB
    UHTHOFF, HK
    [J]. JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1986, 68 (03): : 409 - 413
  • [2] COMPUTED-TOMOGRAPHY IN THE ASSESSMENT AND PLANNING OF COMPLICATED TOTAL HIP-REPLACEMENT
    BARMEIR, E
    DUBOWITZ, B
    ROFFMAN, M
    [J]. ACTA ORTHOPAEDICA SCANDINAVICA, 1982, 53 (04): : 597 - 604
  • [3] 2,012 TOTAL HIP ARTHROPLASTIES - STUDY OF POSTOPERATIVE COURSE AND EARLY COMPLICATIONS
    COVENTRY, MB
    BECKENBAUGH, RD
    NOLAN, DR
    ILSTRUP, DM
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1974, A 56 (02) : 273 - 284
  • [4] The effect of the orientation of the acetabular and femoral components on the range of motion of the hip at different head-neck ratios
    D'Lima, DD
    Urquhart, AG
    Buehler, KO
    Walker, RH
    Colwell, CW
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2000, 82A (03) : 315 - 321
  • [5] Garcia-Cimbrelo E, 1992, J Arthroplasty, V7, P149, DOI 10.1016/0883-5403(92)90008-E
  • [6] EVALUATION OF ACETABULAR ANTEVERSION FOLLOWING TOTAL HIP ARTHROPLASTY - NECESSITY OF PROPER CENTERING
    GOERGEN, TG
    RESNICK, D
    [J]. BRITISH JOURNAL OF RADIOLOGY, 1975, 48 (568) : 259 - 260
  • [7] Accuracy of intraoperative assessment of acetabular prosthesis placement
    Hassan, DM
    Johnston, GHF
    Dust, WNC
    Watson, G
    Dolovich, AT
    [J]. JOURNAL OF ARTHROPLASTY, 1998, 13 (01) : 80 - 84
  • [8] CT DETERMINATION OF FEMORAL TORSION
    HERNANDEZ, RJ
    TACHDJIAN, MO
    POZNANSKI, AK
    DIAS, LS
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1981, 137 (01) : 97 - 101
  • [9] DISLOCATION FOLLOWING TOTAL HIP-ARTHROPLASTY
    KRISTIANSEN, B
    JORGENSEN, L
    HOLMICH, P
    [J]. ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 1985, 103 (06) : 375 - 377
  • [10] The effect of acetabular cup orientations on limiting hip rotation
    Kummer, FJ
    Shah, S
    Iyer, S
    DiCesare, PE
    [J]. JOURNAL OF ARTHROPLASTY, 1999, 14 (04) : 509 - 513