Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels Tapping the Potential of a New Technology for Stent Imaging

被引:60
作者
von Spiczak, Jochen [1 ]
Mannil, Manoj [1 ]
Peters, Benjamin [1 ]
Hickethier, Tilman [2 ]
Baer, Matthias [3 ]
Henning, Andre [3 ]
Schmidt, Bernhard [3 ,4 ]
Flohr, Thomas [3 ]
Manka, Robert [1 ,5 ,6 ]
Maintz, David [2 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[3] Siemens Healthcare GmbH, Forchheim, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[5] Univ Hosp Zurich, Dept Cardiol, Univ Heart Ctr, Zurich, Switzerland
[6] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
关键词
computed tomography; photon counting detector; coronary artery stents; convolution kernel; AFFIRMED ITERATIVE RECONSTRUCTION; IN-VITRO EXPERIENCE; CORONARY-STENTS; CT; DETECTOR; FEASIBILITY; ANGIOGRAPHY; PERFORMANCE; STRENGTH; IMAGES;
D O I
10.1097/RLI.0000000000000485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. Materials and Methods For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 x 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I46(3)). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q70(3)) and level 5 (Q70(5)) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Results Interreader and intrareader reliability were excellent ( = 0.953, ICCs = 0.891-0.999, and = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 0.5 vs D70: 2.9 +/- 0.3; P < 0.001), in-stent diameter difference (1.5 +/- 0.3 vs 1.0 +/- 0.3 mm; P < 0.001), and image sharpness (728 +/- 246 vs 2069 +/- 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 +/- 76 vs 158 +/- 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 +/- 1, D70: 111 +/- 3, Q70(3): 65 +/- 2, Q70(5): 46 +/- 2 CT numbers; P < 0.001 for all comparisons). Conclusions A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
[41]   Photon-counting computed tomography versus energy-integrating computed tomography for detection of small liver lesions: comparison using a virtual framework imaging [J].
Felice, Nicholas ;
Wildman-Tobriner, Benjamin ;
Segars, William Paul ;
Bashir, Mustafa R. ;
Marin, Daniele ;
Samei, Ehsan ;
Abadi, Ehsan .
JOURNAL OF MEDICAL IMAGING, 2024, 11 (05) :53502
[42]   Dual-Contrast Biphasic Liver Imaging With Iodine and Gadolinium Using Photon-Counting Detector Computed Tomography An Exploratory Animal Study [J].
Ren, Liqiang ;
Huber, Nathan ;
Rajendran, Kishore ;
Fletcher, Joel G. ;
McCollough, Cynthia H. ;
Yu, Lifeng .
INVESTIGATIVE RADIOLOGY, 2022, 57 (02) :122-129
[43]   Quantitative Spectral K-Edge Imaging in Preclinical Photon-Counting X-Ray Computed Tomography [J].
de Vries, Anke ;
Roessl, Ewald ;
Kneepkens, Esther ;
Thran, Axel ;
Brendel, Bernhard ;
Martens, Gerhard ;
Proska, Roland ;
Nicolay, Klaas ;
Gruell, Holger .
INVESTIGATIVE RADIOLOGY, 2015, 50 (04) :297-304
[44]   Multicolor spectral photon-counting computed tomography: in vivo dual contrast imaging with a high count rate scanner [J].
Cormode, David P. ;
Si-Mohamed, Salim ;
Bar-Ness, Daniel ;
Sigovan, Monica ;
Naha, Pratap C. ;
Balegamire, Joelle ;
Lavenne, Franck ;
Coulon, Philippe ;
Roessl, Ewald ;
Bartels, Matthias ;
Rokni, Michal ;
Blevis, Ira ;
Boussel, Loic ;
Douek, Philippe .
SCIENTIFIC REPORTS, 2017, 7
[45]   Evaluation of spectral photon counting computed tomography K-edge imaging for determination of gold nanoparticle biodistribution in vivo [J].
Si-Mohamed, Salim ;
Cormode, David P. ;
Bar-Ness, Daniel ;
Sigovan, Monica ;
Naha, Pratap C. ;
Langlois, Jean-Baptiste ;
Chalabreysse, Lara ;
Coulon, Philippe ;
Blevis, Ira ;
Roessl, Ewald ;
Erhard, Klaus ;
Boussel, Loic ;
Douek, Philippe .
NANOSCALE, 2017, 9 (46) :18246-18257
[46]   Virtual Noncontrast Imaging of the Liver Using Photon-Counting Detector Computed Tomography A Systematic Phantom and Patient Study [J].
Sartoretti, Thomas ;
Mergen, Victor ;
Higashigaito, Kai ;
Eberhard, Matthias ;
Alkadhi, Hatem ;
Euler, Andre .
INVESTIGATIVE RADIOLOGY, 2022, 57 (07) :488-493
[47]   Potential of photon counting computed tomography derived spectral reconstructions to reduce beam-hardening artifacts in chest CT [J].
Haag, Florian ;
Hokamp, Nils Grosse ;
Overhoff, Daniel ;
Dasegowda, Giridhar ;
Kuru, Mustafa ;
Noerenberg, Dominik ;
Schoenberg, Stefan O. ;
Kalra, Mannudeep K. ;
Froelich, Matthias F. .
EUROPEAN JOURNAL OF RADIOLOGY, 2024, 175
[48]   Dual-source photon-counting computed tomography for coronary in-stent observation: influence of heart rate and virtual monoenergetic image [J].
Ogawa, Ryo ;
Yanagawa, Masahiro ;
Hata, Akinori ;
Yamagata, Kazuki ;
Ninomiya, Keisuke ;
Doi, Shuhei ;
Kikuchi, Noriko ;
Tokuda, Yukiko ;
Chimura, Misato ;
Nakamura, Daisuke ;
Itoh, Toshihide ;
Kido, Teruhito ;
Tomiyama, Noriyuki .
INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2024, 40 (10) :2117-2124
[49]   Paediatric high-pitch lung imaging with photon-counting detector computed tomography: a dose reduction phantom study [J].
Michael Zellner ;
Thomas Sartoretti ;
Thomas Flohr ;
Thomas Frauenfelder ;
Hatem Alkadhi ;
Christian J. Kellenberger ;
Victor Mergen .
Pediatric Radiology, 2025, 55 (6) :1191-1201
[50]   Potential of contrast agents based on high-Z elements for contrast-enhanced photon-counting computed tomography [J].
Amato, Carlo ;
Klein, Laura ;
Wehrse, Eckhard ;
Rotkopf, Lukas T. ;
Sawall, Stefan ;
Maier, Joscha ;
Ziener, Christian H. ;
Schlemmer, Heinz-Peter ;
Kachelriess, Marc .
MEDICAL PHYSICS, 2020, 47 (12) :6179-6190