Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels Tapping the Potential of a New Technology for Stent Imaging

被引:60
作者
von Spiczak, Jochen [1 ]
Mannil, Manoj [1 ]
Peters, Benjamin [1 ]
Hickethier, Tilman [2 ]
Baer, Matthias [3 ]
Henning, Andre [3 ]
Schmidt, Bernhard [3 ,4 ]
Flohr, Thomas [3 ]
Manka, Robert [1 ,5 ,6 ]
Maintz, David [2 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[3] Siemens Healthcare GmbH, Forchheim, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[5] Univ Hosp Zurich, Dept Cardiol, Univ Heart Ctr, Zurich, Switzerland
[6] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
关键词
computed tomography; photon counting detector; coronary artery stents; convolution kernel; AFFIRMED ITERATIVE RECONSTRUCTION; IN-VITRO EXPERIENCE; CORONARY-STENTS; CT; DETECTOR; FEASIBILITY; ANGIOGRAPHY; PERFORMANCE; STRENGTH; IMAGES;
D O I
10.1097/RLI.0000000000000485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. Materials and Methods For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 x 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I46(3)). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q70(3)) and level 5 (Q70(5)) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Results Interreader and intrareader reliability were excellent ( = 0.953, ICCs = 0.891-0.999, and = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 0.5 vs D70: 2.9 +/- 0.3; P < 0.001), in-stent diameter difference (1.5 +/- 0.3 vs 1.0 +/- 0.3 mm; P < 0.001), and image sharpness (728 +/- 246 vs 2069 +/- 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 +/- 76 vs 158 +/- 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 +/- 1, D70: 111 +/- 3, Q70(3): 65 +/- 2, Q70(5): 46 +/- 2 CT numbers; P < 0.001 for all comparisons). Conclusions A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [31] Imaging performance of phase-contrast breast computed tomography with synchrotron radiation and a CdTe photon-counting detector
    Sarno, A.
    Mettivier, G.
    Golosio, B.
    Oliva, P.
    Spandre, G.
    Di Lillo, F.
    Fedon, C.
    Longo, R.
    Russo, P.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2016, 32 (05): : 681 - 690
  • [32] High-Resolution Chest Computed Tomography Imaging of the Lungs Impact of 1024 Matrix Reconstruction and Photon-Counting Detector Computed Tomography
    Bartlett, David J.
    Koo, Chi Wan
    Bartholmai, Brian J.
    Rajendran, Kishore
    Weaver, Jayse M.
    Halaweish, Ahmed E.
    Leng, Shuai
    McCollough, Cynthia H.
    Fletcher, Joel G.
    INVESTIGATIVE RADIOLOGY, 2019, 54 (03) : 129 - 137
  • [33] Dual-Source Photon-Counting Computed Tomography-Part III: Clinical Overview of Vascular Applications beyond Cardiac and Neuro Imaging
    Meloni, Antonella
    Cademartiri, Filippo
    Pistoia, Laura
    Degiorgi, Giulia
    Clemente, Alberto
    De Gori, Carmelo
    Positano, Vincenzo
    Celi, Simona
    Berti, Sergio
    Emdin, Michele
    Panetta, Daniele
    Menichetti, Luca
    Punzo, Bruna
    Cavaliere, Carlo
    Bossone, Eduardo
    Saba, Luca
    Cau, Riccardo
    La Grutta, Ludovico
    Maffei, Erica
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (11)
  • [34] Photon-Counting Computed Tomography for Vascular Imaging of the Head and Neck First In Vivo Human Results
    Symons, Rolf
    Reich, Daniel S.
    Bagheri, Mohammadhadi
    Cork, Tyler E.
    Krauss, Bernhard
    Ulzheimer, Stefan
    Kappler, Steffen
    Bluemke, David A.
    Pourmorteza, Amir
    INVESTIGATIVE RADIOLOGY, 2018, 53 (03) : 135 - 142
  • [35] Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography
    Huber, Nathan R.
    Ferrero, Andrea
    Rajendran, Kishore
    Baffour, Francis
    Glazebrook, Katrina N.
    Diehn, Felix E.
    Inoue, Akitoshi
    Fletcher, Joel G.
    Yu, Lifeng
    Leng, Shuai
    McCollough, Cynthia H.
    PHYSICS IN MEDICINE AND BIOLOGY, 2022, 67 (17)
  • [36] Photon-Counting Detector Computed Tomography (PCD-CT): A New Era for Cardiovascular Imaging? Current Status and Future Outlooks
    Lacaita, Pietro G.
    Luger, Anna
    Troger, Felix
    Widmann, Gerlig
    Feuchtner, Gudrun M.
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2024, 11 (04)
  • [37] Human Imaging With Photon Counting-Based Computed Tomography at Clinical Dose Levels: Contrast-to-Noise Ratio and Cadaver Studies
    Gutjahr, Ralf
    Halaweish, Ahmed F.
    Yu, Zhicong
    Leng, Shuai
    Yu, Lifeng
    Li, Zhoubo
    Jorgensen, Steven M.
    Ritman, Erik L.
    Kappler, Steffen
    McCollough, Cynthia H.
    INVESTIGATIVE RADIOLOGY, 2016, 51 (07) : 421 - 429
  • [38] Sensitivity of Photon-Counting Based K-Edge Imaging in X-ray Computed Tomography
    Roessl, Ewald
    Brendel, Bernhard
    Engel, Klaus-Juergen
    Schlomka, Jens-Peter
    Thran, Axel
    Proksa, Roland
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2011, 30 (09) : 1678 - 1690
  • [39] Polyenergetic reconstruction mitigates streak artifacts by dual source imaging in chest photon counting detector computed tomography
    Maisuria, Dhruw
    Chamberlin, Jordan H.
    Baruah, Dhiraj
    Hinen, Shaun
    O'Doherty, Jim
    Mcguire, Aaron
    Knight, Heather
    Schoepf, U. Joseph
    Munden, Reginald F.
    Kabakus, Ismail M.
    CLINICAL IMAGING, 2024, 113
  • [40] The polychromatic retrigger: a new tool to mitigate pileup in spectral photon-counting computed-tomography
    Amato, Carlo
    Disch, Christian
    Zambon, Pietro
    FRONTIERS IN PHYSICS, 2024, 12