Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels Tapping the Potential of a New Technology for Stent Imaging

被引:60
作者
von Spiczak, Jochen [1 ]
Mannil, Manoj [1 ]
Peters, Benjamin [1 ]
Hickethier, Tilman [2 ]
Baer, Matthias [3 ]
Henning, Andre [3 ]
Schmidt, Bernhard [3 ,4 ]
Flohr, Thomas [3 ]
Manka, Robert [1 ,5 ,6 ]
Maintz, David [2 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[3] Siemens Healthcare GmbH, Forchheim, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[5] Univ Hosp Zurich, Dept Cardiol, Univ Heart Ctr, Zurich, Switzerland
[6] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
关键词
computed tomography; photon counting detector; coronary artery stents; convolution kernel; AFFIRMED ITERATIVE RECONSTRUCTION; IN-VITRO EXPERIENCE; CORONARY-STENTS; CT; DETECTOR; FEASIBILITY; ANGIOGRAPHY; PERFORMANCE; STRENGTH; IMAGES;
D O I
10.1097/RLI.0000000000000485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. Materials and Methods For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 x 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I46(3)). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q70(3)) and level 5 (Q70(5)) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Results Interreader and intrareader reliability were excellent ( = 0.953, ICCs = 0.891-0.999, and = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 0.5 vs D70: 2.9 +/- 0.3; P < 0.001), in-stent diameter difference (1.5 +/- 0.3 vs 1.0 +/- 0.3 mm; P < 0.001), and image sharpness (728 +/- 246 vs 2069 +/- 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 +/- 76 vs 158 +/- 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 +/- 1, D70: 111 +/- 3, Q70(3): 65 +/- 2, Q70(5): 46 +/- 2 CT numbers; P < 0.001 for all comparisons). Conclusions A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [21] A review of applications of photon-counting computed tomography in head and neck imaging
    Dogra, Siddhant
    Shekhrajka, Nitesh
    Moonis, Gul
    BRITISH JOURNAL OF RADIOLOGY, 2024,
  • [22] Virtual monochromatic imaging reduces beam hardening artefacts in cardiac interior photon counting computed tomography: a phantom study with cadaveric specimens
    Inkinen, Satu I.
    Juntunen, Mikael A. K.
    Ketola, Juuso
    Korhonen, Kristiina
    Sepponen, Pasi
    Kotiaho, Antti
    Pohjanen, Vesa-Matti
    Nieminen, Miika
    BIOMEDICAL PHYSICS & ENGINEERING EXPRESS, 2022, 8 (01)
  • [23] Imaging performance of a LaBr3:Ce scintillation detector for photon counting x-ray computed tomography: Simulation study
    Taguchi, Katsuyuki
    Schaart, Dennis R.
    Goorden, Marlies C.
    Hsieh, Scott S.
    MEDICAL PHYSICS, 2024, : 158 - 170
  • [24] High Spatial-Resolution Skull Base Imaging With Photon-Counting Computed Tomography and Energy-Integrating Computed Tomography: A Comparative Phantom Study
    Rajagopal, Jayasai R.
    Schwartz, Fides R.
    Solomon, Justin B.
    Enterline, David S.
    Samei, Ehsan
    JOURNAL OF COMPUTER ASSISTED TOMOGRAPHY, 2023, 47 (04) : 613 - 620
  • [25] Assessing beam hardening artifacts in coronary stent imaging using different CT acquisition parameters on photon-counting detector computed tomography
    Adolf, Rafael
    Ried, Isabelle
    Will, Albrecht
    Hendrich, Eva
    Bressem, Keno
    Engel, Leif-Christoph
    Hadamitzky, Martin
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2025,
  • [26] 150-μm Spatial Resolution Using Photon-Counting Detector Computed Tomography Technology Technical Performance and First Patient Images
    Leng, Shuai
    Rajendran, Kishore
    Gong, Hao
    Zhou, Wei
    Halaweish, Ahmed F.
    Henning, Andre
    Kappler, Steffen
    Baer, Matthias
    Fletcher, Joel G.
    McCollough, Cynthia H.
    INVESTIGATIVE RADIOLOGY, 2018, 53 (11) : 655 - 662
  • [27] Photon Counting Computed Tomography for Accurate Cribriform Plate (Lamina Cribrosa) Imaging in Adult Patients
    Klempka, Anna
    Ackermann, Eduardo
    Clausen, Sven
    Groden, Christoph
    TOMOGRAPHY, 2024, 10 (03) : 400 - 414
  • [28] Value of Ultrahigh-Resolution Photon-Counting Detector Computed Tomography in Cardiac Imaging
    Kravchenko, Dmitrij
    Hagar, Muhammad Taha
    Vecsey-Nagy, Milan
    Tremamunno, Giuseppe
    Szilveszter, Balint
    Vattay, Borbala
    Zsarnoczay, Emese
    Beke, Samuel
    Maurovich-Horvat, Pal
    Emrich, Tilman
    Varga-Szemes, Akos
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2025, 42 (02):
  • [29] Quantitative cartilage imaging using spectral photon-counting detector based computed tomography
    Endran, Kishore Raj
    Tao, Shengzhen
    Benike, Amy
    Leng, Shuai
    McCollough, Cynthia
    MEDICAL IMAGING 2019: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING, 2019, 10953
  • [30] Evaluation of gold K-edge imaging using spectral computed tomography with a photon-counting detector: A Monte Carlo simulation study
    Kang, Sooncheol
    Eom, Jisoo
    Kim, Burnyoung
    Lee, Seungwan
    OPTIK, 2017, 140 : 253 - 260