Photon Counting Computed Tomography With Dedicated Sharp Convolution Kernels Tapping the Potential of a New Technology for Stent Imaging

被引:60
作者
von Spiczak, Jochen [1 ]
Mannil, Manoj [1 ]
Peters, Benjamin [1 ]
Hickethier, Tilman [2 ]
Baer, Matthias [3 ]
Henning, Andre [3 ]
Schmidt, Bernhard [3 ,4 ]
Flohr, Thomas [3 ]
Manka, Robert [1 ,5 ,6 ]
Maintz, David [2 ]
Alkadhi, Hatem [1 ]
机构
[1] Univ Hosp Zurich, Inst Diagnost & Intervent Radiol, Raemistr 100, CH-8091 Zurich, Switzerland
[2] Univ Hosp Cologne, Dept Radiol, Cologne, Germany
[3] Siemens Healthcare GmbH, Forchheim, Germany
[4] Univ Erlangen Nurnberg, Inst Med Phys, Erlangen, Germany
[5] Univ Hosp Zurich, Dept Cardiol, Univ Heart Ctr, Zurich, Switzerland
[6] Univ & ETH Zurich, Inst Biomed Engn, Zurich, Switzerland
关键词
computed tomography; photon counting detector; coronary artery stents; convolution kernel; AFFIRMED ITERATIVE RECONSTRUCTION; IN-VITRO EXPERIENCE; CORONARY-STENTS; CT; DETECTOR; FEASIBILITY; ANGIOGRAPHY; PERFORMANCE; STRENGTH; IMAGES;
D O I
10.1097/RLI.0000000000000485
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Objectives The aims of this study were to assess the value of a dedicated sharp convolution kernel for photon counting detector (PCD) computed tomography (CT) for coronary stent imaging and to evaluate to which extent iterative reconstructions can compensate for potential increases in image noise. Materials and Methods For this in vitro study, a phantom simulating coronary artery stenting was prepared. Eighteen different coronary stents were expanded in plastic tubes of 3 mm diameter. Tubes were filled with diluted contrast agent, sealed, and immersed in oil calibrated to an attenuation of -100 HU simulating epicardial fat. The phantom was scanned in a modified second generation 128-slice dual-source CT scanner (SOMATOM Definition Flash, Siemens Healthcare, Erlangen, Germany) equipped with both a conventional energy integrating detector and PCD. Image data were acquired using the PCD part of the scanner with 48 x 0.25 mm slices, a tube voltage of 100 kVp, and tube current-time product of 100 mAs. Images were reconstructed using a conventional convolution kernel for stent imaging with filtered back-projection (B46) and with sinogram-affirmed iterative reconstruction (SAFIRE) at level 3 (I46(3)). For comparison, a dedicated sharp convolution kernel with filtered back-projection (D70) and SAFIRE level 3 (Q70(3)) and level 5 (Q70(5)) was used. The D70 and Q70 kernels were specifically designed for coronary stent imaging with PCD CT by optimizing the image modulation transfer function and the separation of contrast edges. Two independent, blinded readers evaluated subjective image quality (Likert scale 0-3, where 3 = excellent), in-stent diameter difference, in-stent attenuation difference, mathematically defined image sharpness, and noise of each reconstruction. Interreader reliability was calculated using Goodman and Kruskal's and intraclass correlation coefficients (ICCs). Differences in image quality were evaluated using a Wilcoxon signed-rank test. Differences in in-stent diameter difference, in-stent attenuation difference, image sharpness, and image noise were tested using a paired-sample t test corrected for multiple comparisons. Results Interreader and intrareader reliability were excellent ( = 0.953, ICCs = 0.891-0.999, and = 0.996, ICCs = 0.918-0.999, respectively). Reconstructions using the dedicated sharp convolution kernel yielded significantly better results regarding image quality (B46: 0.4 0.5 vs D70: 2.9 +/- 0.3; P < 0.001), in-stent diameter difference (1.5 +/- 0.3 vs 1.0 +/- 0.3 mm; P < 0.001), and image sharpness (728 +/- 246 vs 2069 +/- 411 CT numbers/voxel; P < 0.001). Regarding in-stent attenuation difference, no significant difference was observed between the 2 kernels (151 +/- 76 vs 158 +/- 92 CT numbers; P = 0.627). Noise was significantly higher in all sharp convolution kernel images but was reduced by 41% and 59% by applying SAFIRE levels 3 and 5, respectively (B46: 16 +/- 1, D70: 111 +/- 3, Q70(3): 65 +/- 2, Q70(5): 46 +/- 2 CT numbers; P < 0.001 for all comparisons). Conclusions A dedicated sharp convolution kernel for PCD CT imaging of coronary stents yields superior qualitative and quantitative image characteristics compared with conventional reconstruction kernels. Resulting higher noise levels in sharp kernel PCD imaging can be partially compensated with iterative image reconstruction techniques.
引用
收藏
页码:486 / 494
页数:9
相关论文
共 50 条
  • [1] Coronary stent imaging in photon counting computed Tomography: Optimization of reconstruction kernels in a phantom
    Michael, Arwed Elias
    Schoenbeck, Denise
    Becker-Assmann, Jendrik
    Niehoff, Julius Henning
    Flohr, Thomas
    Schmidt, Bernhard
    Panknin, Christoph
    Baer-Beck, Matthias
    Hickethier, Tilman
    Maintz, David
    Bunck, Alexander Christian
    Borggrefe, Jan
    Wiemer, Marcus
    Rudolph, Volker
    Kroeger, Jan Robert
    EUROPEAN JOURNAL OF RADIOLOGY, 2023, 166
  • [2] Coronary stent imaging in photon counting computed tomography: improved imaging of in-stent stenoses in a phantom with optimized reconstruction kernels
    Michael, Arwed Elias
    Schoenbeck, Denise
    Becker-Assmann, Jendrik
    Haag, Nina Pauline
    Niehoff, Julius Henning
    Schmidt, Bernhard
    Panknin, Christoph
    Baer-Beck, Matthias
    Hickethier, Tilman
    Maintz, David
    Bunck, Alexander C.
    Gertz, Roman Johannes
    Borggrefe, Jan
    Kroeger, Jan Robert
    BJR OPEN, 2024, 6 (01):
  • [3] Photon-Counting Computed Tomography for Coronary Stent Imaging In Vitro Evaluation of 28 Coronary Stents
    Petritsch, Bernhard
    Petri, Nils
    Weng, Andreas M.
    Petersilka, Martin
    Allmendinger, Thomas
    Bley, Thorsten A.
    Gassenmaier, Tobias
    INVESTIGATIVE RADIOLOGY, 2021, 56 (10) : 653 - 660
  • [4] Spectral Photon-Counting Computed Tomography for Coronary Stent Imaging Evaluation of the Potential Clinical Impact for the Delineation of In-Stent Restenosis
    Bratke, Grischa
    Hickethier, Tilman
    Bar-Ness, Daniel
    Bunck, Alexander Christian
    Maintz, David
    Pahn, Gregor
    Coulon, Philippe
    Si-Mohamed, Salim
    Douek, Philippe
    Sigovan, Monica
    INVESTIGATIVE RADIOLOGY, 2020, 55 (02) : 61 - 67
  • [5] New contrast agents for photon-counting computed tomography
    Sawall, Stefan
    RADIOLOGIE, 2023, 63 (07): : 507 - 512
  • [6] Dedicated Breast Computed Tomography With a Photon-Counting Detector Initial Results of Clinical In Vivo Imaging
    Berger, Nicole
    Marcon, Magda
    Saltybaeva, Natalia
    Kalender, Willi A.
    Alkadhi, Hatem
    Frauenfelder, Thomas
    Boss, Andreas
    INVESTIGATIVE RADIOLOGY, 2019, 54 (07) : 409 - 418
  • [7] Potential benefits of photon counting detector computed tomography in pediatric imaging
    Horst, Kelly K.
    Yu, Lifeng
    Mccollough, Cynthia H.
    Esquivel, Andrea
    Thorne, Jamison E.
    Rajiah, Prabhakar Shanta
    Baffour, Francis
    Hull, Nathan C.
    Weber, Nikkole M.
    Thacker, Paul G.
    Thomas, Kristen B.
    Binkovitz, Larry A.
    Guerin, Julie B.
    Fletcher, Joel G.
    BRITISH JOURNAL OF RADIOLOGY, 2023, 96 (1152)
  • [8] First In-Human Results of Computed Tomography Angiography for Coronary Stent Assessment With a Spectral Photon Counting Computed Tomography
    Boccalini, Sara
    Si-Mohamed, Salim A.
    Lacombe, Hugo
    Diaw, Adja
    Varasteh, Mohammad
    Rodesch, Pierre-Antoine
    Villien, Marjorie
    Sigovan, Monica
    Dessouky, Riham
    Coulon, Philippe
    Yagil, Yoad
    Lahoud, Elias
    Erhard, Klaus
    Rioufol, Gilles
    Finet, Gerard
    Bonnefoy-Cudraz, Eric
    Bergerot, Cyrille
    Boussel, Loic
    Douek, Philippe C.
    INVESTIGATIVE RADIOLOGY, 2022, 57 (04) : 212 - 221
  • [9] Photon-counting detector computed tomography in cardiac imaging
    Sharma, Simran P.
    Lemmens, Marie-Julie D. K.
    Smulders, Martijn W.
    Budde, Ricardo P. J.
    Hirsch, Alexander
    Mihl, Casper
    NETHERLANDS HEART JOURNAL, 2024, 32 (11) : 405 - 416
  • [10] Imaging of intracranial hemorrhage in photon counting computed tomography using virtual monoenergetic images
    Schoenbeck, Denise
    Sacha, Alexander
    Niehoff, Julius Henning
    Moenninghoff, Christoph
    Borggrefe, Jan
    Horstmeier, Sebastian
    Surov, Alexey
    Shahzadi, Iram
    Knappe, Ulrich
    Kroeger, Jan Robert
    Michael, Arwed Elias
    NEURORADIOLOGY, 2024, 66 (05) : 729 - 736