Image-based view-angle independent cardiorespiratory motion gating and coronary sinus catheter tracking for x-ray-guided cardiac electrophysiology procedures

被引:5
作者
Panayiotou, Maria [1 ]
Rhode, Kawal S. [1 ]
King, Andrew P. [1 ]
Ma, Yingliang [1 ]
Cooklin, Michael [2 ]
O'Neill, Mark [2 ]
Gill, Jaswinder [2 ]
Rinaldi, C. A. [2 ]
Housden, R. James [1 ]
机构
[1] Kings Coll London, Div Imaging Sci & Biomed Engn, London SE1 7EH, England
[2] Guys & St Thomas Hosp NHS Fdn Trust, Dept Cardiol, London, England
基金
英国工程与自然科学研究理事会;
关键词
cardiorespiratory motion gating; principal component analysis; cardiac electrophysiology; 3D rotational angiography; x-ray fluoroscopy; RESPIRATORY MOTION; INTERVENTIONAL NAVIGATION; ORGAN MOTION; ABLATION; COMPENSATION; REGISTRATION; SYSTEM; MODEL; MR;
D O I
10.1088/0031-9155/60/20/8087
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Determination of the cardiorespiratory phase of the heart has numerous applications during cardiac imaging. In this article we propose a novel view-angle independent near-real time cardiorespiratory motion gating and coronary sinus (CS) catheter tracking technique for x-ray fluoroscopy images that are used to guide cardiac electrophysiology procedures. The method is based on learning CS catheter motion using principal component analysis and then applying the derived motion model to unseen images taken at arbitrary projections, using the epipolar constraint. This method is also able to track the CS catheter throughout the x-ray images in any arbitrary subsequent view. We also demonstrate the clinical application of our model on rotational angiography sequences. We validated our technique in normal and very low dose phantom and clinical datasets. For the normal dose clinical images we established average systole, end-expiration and end-inspiration gating success rates of 100%, 85.7%, and 92.3%, respectively. For very low dose applications, the technique was able to track the CS catheter with median errors not exceeding 1 mm for all tracked electrodes. Average gating success rates of 80.3%, 71.4%, and 69.2% were established for the application of the technique on clinical datasets, even with a dose reduction of more than 10 times. In rotational sequences at normal dose, CS tracking median errors were within 1.2 mm for all electrodes, and the gating success rate was 100%, for view angles from RAO 90 degrees to LAO 90 degrees. This view-angle independent technique can extract clinically useful cardiorespiratory motion information using x-ray doses significantly lower than those currently used in clinical practice.
引用
收藏
页码:8087 / 8108
页数:22
相关论文
共 45 条
  • [1] [Anonymous], 2002, Principal components analysis
  • [2] [Anonymous], 2001, Robotica, DOI DOI 10.1017/S0263574700223217
  • [3] Respiratory motion compensation by model-based catheter tracking during EP procedures
    Brost, A.
    Liao, R.
    Strobel, N.
    Hornegger, J.
    [J]. MEDICAL IMAGE ANALYSIS, 2010, 14 (05) : 695 - 706
  • [4] Constrained Registration for Motion Compensation in Atrial Fibrillation Ablation Procedures
    Brost, Alexander
    Wimmer, Andreas
    Liao, Rui
    Bourier, Felix
    Koch, Martin
    Strobel, Norbert
    Kurzidim, Klaus
    Hornegger, Joachim
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2012, 31 (04) : 870 - 881
  • [5] Polyvinyl alcohol cryogel: An ideal phantom material for MR studies of arterial flow and elasticity
    Chu, KC
    Rutt, BK
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1997, 37 (02) : 314 - 319
  • [6] Fast and robust diaphragm detection and tracking in cardiac x-ray projection images
    Condurache, A
    Aach, T
    Eck, K
    Bredno, J
    Stehle, T
    [J]. Medical Imaging 2005: Image Processing, Pt 1-3, 2005, 5747 : 1766 - 1775
  • [7] An augmented reality system for patient-specific guidance of cardiac catheter ablation procedures
    De Buck, S
    Maes, F
    Ector, J
    Bogaert, J
    Dymarkowski, S
    Heidbüchel, H
    Suetens, P
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 2005, 24 (11) : 1512 - 1524
  • [8] Biplane three-dimensional augmented fluoroscopy as single navigation tool for ablation of atrial fibrillation:: Accuracy and clinical value
    Ector, Joris
    De Buck, Stijn
    Huybrechts, Wim
    Nuyens, Dieter
    Dymarkowski, Steven
    Bogaert, Jan
    Maes, Frederik
    Heidbuchel, Hein
    [J]. HEART RHYTHM, 2008, 5 (07) : 957 - 964
  • [9] Esteghamatian M, 2008, 9 INT C SIGN P, P1325
  • [10] DECOMPOSITION OF TRANSFORMATION-MATRICES FOR ROBOT VISION
    GANAPATHY, S
    [J]. PATTERN RECOGNITION LETTERS, 1984, 2 (06) : 401 - 412