Ex Vivo Assessment of Carbon Tetrachloride (CCl4)-Induced Chronic Injury Using Polarized Light Spectroscopy

被引:11
作者
Ahmad, Manzoor [1 ]
Ali, Safdar [1 ,2 ]
Mehmood, Malik Sajjad [1 ]
Ali, Hamid [3 ]
Khurshid, Ahmat [1 ]
Firdous, Shamaraz [4 ]
Muhammad, Saleh [2 ]
Ikram, Masroor [1 ]
机构
[1] Pakistan Inst Engn & Appl Sci, Islamabad 45650, Pakistan
[2] Hazara Univ, Dept Phys, Mansehra, Pakistan
[3] Univ Karachi Pakistan, ICCB, Panjwani Ctr Mol Med & Drugs Res, Karachi, Pakistan
[4] Natl Inst Laser & Optron, Islamabad 45650, Pakistan
关键词
Polarized light spectroscopy; Tissue diagnostics; Mueller matrix polarimetry; Light depolarization; Linear retardance; Liver fibrosis; TURBID MEDIA; LIPID-PEROXIDATION; OPTICAL-PROPERTIES; BIOLOGICAL TISSUE; MUELLER MATRICES; HEPATITIS-C; LIVER; SCATTERING; DEPOLARIZATION; DIAGNOSTICS;
D O I
10.1366/13-07090
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The liver performs various functions, such as the production and detoxification of chemicals; therefore, it is susceptible to hepatotoxins such as carbon tetrachloride (CCl4), which causes chronic injury. Thus, assessment of injury and its status of severity are of prime importance. Current work reports an ex vivo study for probing the severance of hepatic injury induced by CCl4 with polarized light over the spectral range 400-800 nm. Different concentrations of CCl4 were used to induce varying severity of hepatic injury in a rat model. Linear retardance, depolarization rates, and diagonal Mueller matrix elements (m(22), m(33), and m(44)), were successfully used as the distinguishing criterion for normal and different liver injuries. Our results show that linear retardance for injured liver samples with lower doses of CCl4 tends to increase when compared with normal liver samples, while samples injured at higher doses of CCl4 offer almost no retardance. Total, linear, and circular depolarizations follow decreasing trends with increased liver injury severity over the entire investigated wavelength range. Linear polarization states were observed to be better maintained as compared to circular polarization states for all samples. Furthermore, numerical values of diagonal elements of the experimentally measured Mueller matrix also increase with increasing doses of CCl4. Liver fibroses, change in transport albedo, and the relative refractive index of the extracellular matrix caused by CCl4 are responsible for the observed differences. These results will provide a pathway to gauge the severity of injury caused by toxic chemicals.
引用
收藏
页码:1382 / 1389
页数:8
相关论文
共 48 条
[1]   Do different turbid media with matched bulk optical properties also exhibit similar polarization properties? [J].
Ahmad, Manzoor ;
Alali, Sanaz ;
Kim, Anthony ;
Wood, Michael F. G. ;
Ikram, Masroor ;
Vitkin, I. Alex .
BIOMEDICAL OPTICS EXPRESS, 2011, 2 (12) :3248-3258
[2]  
Alali S., 2012, J BIOMED OPT, V17
[3]   Mueller matrix imaging of human colon tissue for cancer diagnostics: how Monte Carlo modeling can help in the interpretation of experimental data [J].
Antonelli, Maria-Rosaria ;
Pierangelo, Angelo ;
Novikova, Tatiana ;
Validire, Pierre ;
Benali, Abdelali ;
Gayet, Brice ;
De Martino, Antonello .
OPTICS EXPRESS, 2010, 18 (10) :10200-10208
[4]   Polarized light scattering spectroscopy for quantitative measurement of epithelial cellular structures in situ [J].
Backman, V ;
Gurjar, R ;
Badizadegan, K ;
Itzkan, L ;
Dasari, RR ;
Perelman, LT ;
Feld, MS .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1999, 5 (04) :1019-1026
[5]   Chronic hepatitis: In vivo proton MR spectroscopic evaluation of the liver and correlation with histopathologic findings [J].
Cho, SG ;
Kim, MY ;
Kim, HJ ;
Kim, YS ;
Choi, W ;
Shin, SH ;
Hong, KC ;
Kim, YB ;
Lee, JH ;
Suh, CH .
RADIOLOGY, 2001, 221 (03) :740-746
[6]   Multi-wavelength fluorescence lifetime spectroscopy: a new approach to the study of endogenous fluorescence in living cells and tissues [J].
Chorvat, D., Jr. ;
Chorvatova, A. .
LASER PHYSICS LETTERS, 2009, 6 (03) :175-193
[7]   Balanced detection for low-noise precision polarimetric measurements of optically active, multiply scattering tissue phantoms [J].
Côté, D ;
Vitkin, IA .
JOURNAL OF BIOMEDICAL OPTICS, 2004, 9 (01) :213-220
[8]   Optimized Mueller polarimeter with liquid crystals [J].
De Martino, A ;
Kim, YK ;
Garcia-Caurel, E ;
Laude, B ;
Drévillon, B .
OPTICS LETTERS, 2003, 28 (08) :616-618
[9]   Mueller matrix polarimetry for improved liver fibrosis diagnosis [J].
Dubreuil, Matthieu ;
Babilotte, Philippe ;
Martin, Loic ;
Sevrain, David ;
Rivet, Sylvain ;
Le Grand, Yann ;
Le Brun, Guy ;
Turlin, Bruno ;
Le Jeune, Bernard .
OPTICS LETTERS, 2012, 37 (06) :1061-1063
[10]   Three-dimensional computation of light scattering from cells [J].
Dunn, A ;
RichardsKortum, R .
IEEE JOURNAL OF SELECTED TOPICS IN QUANTUM ELECTRONICS, 1996, 2 (04) :898-905