Numerical and experimental simulation of the effect of long bone fracture healing stages on ultrasound transmission across an idealized fracture

被引:18
作者
Gheduzzi, S. [1 ]
Dodd, S. P. [1 ]
Miles, A. W. [1 ]
Humphrey, V. F. [2 ]
Cunningham, J. L. [1 ]
机构
[1] Univ Bath, Dept Mech Engn, Ctr Orthopaed Biomech, Bath BA2 7AY, Avon, England
[2] Univ Southampton, ISVR, Southampton SO17 1BJ, Hants, England
关键词
BOVINE ARTICULAR-CARTILAGE; CORTICAL BONE; IN-VITRO; AXIAL TRANSMISSION; WAVE-PROPAGATION; GUIDED-WAVES; SIGNAL LOSS; INTACT; TRANSVERSE; MIMICS;
D O I
10.1121/1.3158938
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The effect of various stages of fracture healing on the amplitude of 200 kHz ultrasonic waves propagating along cortical bone plates and across an idealized fracture has been modeled numerically and experimentally. A simple, water-filled, transverse fracture was used to simulate the inflammatory stage. Next, a symmetric external callus was added to represent the repair stage, while a callus of reducing size was used to simulate the remodeling stage. The variation in the first arrival signal amplitude across the fracture site was calculated and compared with data for an intact plate in order to calculate the fracture transmission loss (FTL) in decibels. The inclusion of the callus reduced the fracture loss. The most significant changes were calculated to occur from the initial inflammatory phase to the formation of a callus (with the FTL reducing from 6.3 to between 5.5 and 3.5 dB, depending on them properties of the callus) and in the remodeling phase where, after a 50% reduction in the size of the callus, the FTL reduced to between 2.0 and 1.3 dB. Qualitatively, the experimental results follow the model predictions. The change in signal amplitude with callus geometry and elastic properties could potentially be used to monitor the healing process. (C) 2009 Acoustical Society of America. [DOI: 10.1121/1.3158938]
引用
收藏
页码:887 / 894
页数:8
相关论文
共 22 条
  • [1] Experimental and simulation results on the effect of cortical bone mineralization in ultrasound axial transmission measurements: A model for fracture healing ultrasound monitoring
    Machado, Christiano Bittencourt
    Pereira, Wagner Coelho de A.
    Granke, Mathilde
    Talmant, Maryline
    Padilla, Frederic
    Laugier, Pascal
    BONE, 2011, 48 (05) : 1202 - 1209
  • [2] Modelling the effects of different fracture geometries and healing stages on ultrasound signal loss across a long bone fracture
    Centre for Orthopaedic Biomechanics, Department of Mechanical Engineering, University of Bath, Bath, Avon BA2 7AY, United Kingdom
    不详
    Comput. Methods Biomech. Biomed. Eng., 2007, 5 (371-375): : 371 - 375
  • [3] COMPUTATIONAL EVALUATION OF THE COMPOSITIONAL FACTORS IN FRACTURE HEALING AFFECTING ULTRASOUND AXIAL TRANSMISSION MEASUREMENTS
    Machado, Christiano Bittencourt
    de Albuquerque Pereira, Wagner Coelho
    Talmant, Maryline
    Padilla, Frederic
    Laugier, Pascal
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2010, 36 (08) : 1314 - 1326
  • [4] Effect of ultrasound on bone fracture healing: A computational bioregulatory model
    Vavva, Maria G.
    Grivas, Konstantinos N.
    Carlier, Aurelie
    Polyzos, Demosthenes
    Geris, Liesbet
    Van Oosterwyck, Hans
    Fotiadis, Dimitrios, I
    COMPUTERS IN BIOLOGY AND MEDICINE, 2018, 100 : 74 - 85
  • [5] The effect of teicoplanin on fracture healing: an experimental study
    Gocer, Hasan
    Onger, Mehmet Emin
    Kuyubasi, Numan
    Cirakli, Alper
    Kir, Mustafa Caglar
    EKLEM HASTALIKLARI VE CERRAHISI-JOINT DISEASES AND RELATED SURGERY, 2016, 27 (01): : 16 - 21
  • [6] A review on experimental and numerical investigations of cortical bone fracture
    Kumar, Ajay
    Ghosh, Rajesh
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2022, 236 (03) : 297 - 319
  • [7] AXIAL TRANSMISSION METHOD FOR LONG BONE FRACTURE EVALUATION BY ULTRASONIC GUIDED WAVES: SIMULATION, PHANTOM AND IN VITRO EXPERIMENTS
    Xu, Kailiang
    Ta, Dean
    He, Runxin
    Qin, Yi-Xian
    Wang, Weiqi
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2014, 40 (04) : 817 - 827
  • [8] Fracture toughening mechanism of cortical bone: An experimental and numerical approach
    An, Bingbing
    Liu, Yang
    Arola, Dwayne
    Zhang, Dongsheng
    JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2011, 4 (07) : 983 - 992
  • [9] Ultrasound Propagation Velocity and Broadband Attenuation Can Help Evaluate the Healing Process of an Experimental Fracture
    Barbieri, Giuliano
    Barbieri, Claudio Henrique
    Mazzer, Nilton
    Pela, Carlos Alberto
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2011, 29 (03) : 444 - 451