Evaluation of linear lesion formation and thermodynamics by dragging ablation with the third-generation laser balloon

被引:3
|
作者
Nagase, Takahiko [1 ]
Asano, So [1 ]
Fukunaga, Hiroshi [1 ]
Kasai, Yuhei [1 ]
Inoue, Kanki [1 ]
Sekiguchi, Yukio [1 ]
Tanizaki, Kohei [1 ]
Murai, Tatsuya [2 ]
Nanasato, Mamoru [1 ]
Umemura, Jun [1 ]
Nitta, Junichi [1 ]
Isobe, Mitsuaki [1 ]
机构
[1] Sakakibara Heart Inst, Dept Cardiol, Tokyo, Japan
[2] Sakakibara Heart Inst, Dept Pathol, Tokyo, Japan
来源
HEART RHYTHM O2 | 2022年 / 3卷 / 03期
关键词
Atrial fibrillation; Linear lesion formation; Point-by-point ablation; RAPID mode ablation; Third-generation laser; balloon; PULMONARY; MULTICENTER;
D O I
10.1016/j.hroo.2022.04.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear. OBJECTIVE The purpose of this study was to assess lesion characteristics and thermodynamics in LB3 ablation with a RAPID mode in vitro model. METHODS Chicken muscles were cauterized using LB3 in RAPID mode with 13 W and 15 W and 50% overlapped point-by-point fashion with 7 W/30 seconds, 8.5 W/20 seconds, 10 W/20 seconds, and 12 W/20 seconds. Lesion depth, width, and continuity were compared. Lesion continuity was classified by the visible gap degree categorized from 1 (perfect) to 3 (poor). Thermodynamics and maximum tissue temperatures were assessed under infrared thermographic monitoring. Fifteen and 5 lesions were evaluated per ablation protocol for measurement of lesion size and continuity and for thermographic assessment, respectively. RESULTS Lesion depth and width were smaller in RAPID mode laser ablation than point-by-point laser ablation (P <.001). However, RAPID mode laser ablation revealed sufficient mean lesion depth of 5 mm or more. Lesion continuity was 1 (perfect) in all samples in RAPID mode laser ablation and point-by-point laser ablation (P = 1). Infrared thermographic observation demonstrated fast and gapless linear lesion formation with thermal stacking in RAPID mode laser ablation. Maximum tissue temperature was lower in RAPID mode laser ablation than point-by-point laser ablation (P <.001). CONCLUSION RAPID mode LB3 ablation could provide fast, gapless, and acceptable lesion formation with thermal stacking and moderate tissue temperature rise.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [21] Third-generation treatment of varicose veins: cyanoacrylate adhesive closure and mechanochemical ablation
    Jun, Kang Woong
    Cho, Sungsin
    JOURNAL OF THE KOREAN MEDICAL ASSOCIATION, 2022, 65 (04): : 217 - 224
  • [22] Evaluation of a new third-generation ELISA for the detection of HIV infection
    Yeom, JS
    Lee, JB
    Ryu, SH
    Kang, HJ
    Kim, S
    Kim, YA
    Ahn, SY
    Cha, JE
    Park, JW
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 2006, 36 (01): : 73 - 78
  • [23] Not only power and energy but also balloon size is correlated with lesion formation in laser ablation model in vitro study
    Matsunaga, Y.
    Egami, Y.
    Yano, M.
    Yamato, M.
    Shutta, R.
    Nishino, M.
    Tanouchi, J.
    EUROPEAN HEART JOURNAL, 2020, 41 : 563 - 563
  • [24] Third-generation megahertz-rate pulse burst laser system
    Thurow, Brian S.
    Satija, Aman
    Lynch, Kyle
    APPLIED OPTICS, 2009, 48 (11) : 2086 - 2093
  • [25] The galactic rate of second- and third-generation disc and planet formation
    Hogg, Miriam A.
    Wynn, Graham A.
    Nixon, Chris
    MONTHLY NOTICES OF THE ROYAL ASTRONOMICAL SOCIETY, 2018, 479 (04) : 4486 - 4498
  • [26] Elastographic evaluation of thermal lesion formation with RF ablation
    Techavipoo, U
    Varghese, T
    Zagzebski, JA
    Frank, GR
    Johnson, CD
    Lee, FT
    RADIOLOGY, 2001, 221 : 399 - 399
  • [27] Transseptal Transcatheter Implantation of a Third-Generation Balloon-Expandable Valve in Degenerated Mitral Bioprosthesis
    Jochheim, David
    Khandoga, Alexander
    Bauer, Axel
    Baquet, Moritz
    Theiss, Hans
    Schenzle, Jan
    Hausleiter, Joerg
    Massberg, Steffen
    Mehilli, Julinda
    JACC-CARDIOVASCULAR INTERVENTIONS, 2015, 8 (14) : E241 - E243
  • [28] Clinical Evaluation of Long-term Safety and Effectiveness of a Third-Generation Thermal Uterine Balloon Therapy System for Heavy Menstrual Bleeding
    Cash, Charles, Jr.
    Garza-Leal, Jose
    Donovan, Arthur
    Guidry, Cyrus
    Romanowski, Christine
    Patel, Bababhai
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2012, 19 (04) : 469 - 476
  • [29] Coronary vasculature within a radiofrequency ablation lesion prevents transmural lesion formation: Implications for linear ablation of atrial fibrillation
    Wood, MA
    Fuller, IA
    CIRCULATION, 2000, 102 (18) : 526 - 526
  • [30] Evaluation of a new automated third-generation anti-HCV enzyme immunoassay
    Lavanchy, D
    Steinmann, J
    Moritz, A
    Frei, PC
    JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1996, 10 (05) : 269 - 276