Evaluation of linear lesion formation and thermodynamics by dragging ablation with the third-generation laser balloon

被引:3
|
作者
Nagase, Takahiko [1 ]
Asano, So [1 ]
Fukunaga, Hiroshi [1 ]
Kasai, Yuhei [1 ]
Inoue, Kanki [1 ]
Sekiguchi, Yukio [1 ]
Tanizaki, Kohei [1 ]
Murai, Tatsuya [2 ]
Nanasato, Mamoru [1 ]
Umemura, Jun [1 ]
Nitta, Junichi [1 ]
Isobe, Mitsuaki [1 ]
机构
[1] Sakakibara Heart Inst, Dept Cardiol, Tokyo, Japan
[2] Sakakibara Heart Inst, Dept Pathol, Tokyo, Japan
来源
HEART RHYTHM O2 | 2022年 / 3卷 / 03期
关键词
Atrial fibrillation; Linear lesion formation; Point-by-point ablation; RAPID mode ablation; Third-generation laser; balloon; PULMONARY; MULTICENTER;
D O I
10.1016/j.hroo.2022.04.001
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND The lesion formation properties of a motorized rotational delivery (RAPID) mode, third-generation laser balloon (LB3) ablation compared to point-by-point laser ablation in patients with atrial fibrillation remain unclear. OBJECTIVE The purpose of this study was to assess lesion characteristics and thermodynamics in LB3 ablation with a RAPID mode in vitro model. METHODS Chicken muscles were cauterized using LB3 in RAPID mode with 13 W and 15 W and 50% overlapped point-by-point fashion with 7 W/30 seconds, 8.5 W/20 seconds, 10 W/20 seconds, and 12 W/20 seconds. Lesion depth, width, and continuity were compared. Lesion continuity was classified by the visible gap degree categorized from 1 (perfect) to 3 (poor). Thermodynamics and maximum tissue temperatures were assessed under infrared thermographic monitoring. Fifteen and 5 lesions were evaluated per ablation protocol for measurement of lesion size and continuity and for thermographic assessment, respectively. RESULTS Lesion depth and width were smaller in RAPID mode laser ablation than point-by-point laser ablation (P <.001). However, RAPID mode laser ablation revealed sufficient mean lesion depth of 5 mm or more. Lesion continuity was 1 (perfect) in all samples in RAPID mode laser ablation and point-by-point laser ablation (P = 1). Infrared thermographic observation demonstrated fast and gapless linear lesion formation with thermal stacking in RAPID mode laser ablation. Maximum tissue temperature was lower in RAPID mode laser ablation than point-by-point laser ablation (P <.001). CONCLUSION RAPID mode LB3 ablation could provide fast, gapless, and acceptable lesion formation with thermal stacking and moderate tissue temperature rise.
引用
收藏
页码:311 / 318
页数:8
相关论文
共 50 条
  • [1] Comparison of dragging ablation and point-by-point ablation with a laser balloon on linear lesion formation
    Nagase, Takahiko
    Kobori, Atsushi
    Inaba, Osamu
    Sasaki, Yasuhiro
    Tomizawa, Naoki
    Asano, So
    Fukunaga, Hiroshi
    Mabuchi, Kei
    Inoue, Kanki
    Tanizaki, Kohei
    Murai, Tatsuya
    Iguchi, Nobuo
    Nitta, Junichi
    Isobe, Mitsuaki
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2020, 31 (11) : 2848 - 2856
  • [2] Continuous RAPID-mode ablation with a third-generation laser balloon
    Kondo, Yusuke
    Kajiyama, Takatsugu
    Chiba, Toshinori
    Nakano, Masahiro
    Kobayashi, Yoshio
    IJC HEART & VASCULATURE, 2022, 43
  • [3] Third-generation laser balloon ablation for atrial fibrillation treatment: a multicenter experience
    Rovaris, G.
    Martignani, C.
    Miracapillo, G.
    Colella, A.
    Giaccardi, M.
    Forleo, G. B.
    Giomi, A.
    Giacopelli, D.
    Grassini, D.
    Pozzi, M.
    Montemerlo, E.
    Ziacchi, M.
    Schiavone, M.
    Biffi, M.
    EUROPEAN HEART JOURNAL, 2021, 42 : 519 - 519
  • [4] Third-generation laser balloon ablation: rapid mode applicability is associated with shorter time to pulmonary vein isolation
    Martignani, C.
    Ziacchi, M.
    Statuto, G.
    Bartoli, L.
    Spadotto, A.
    Angeletti, A.
    Massaro, G.
    Diemberger, I.
    Sorrentino, S.
    Capobianco, C.
    Giacopelli, D.
    Bassini, M.
    Grassini, D.
    Galie, N.
    Biffi, M.
    EUROPEAN HEART JOURNAL, 2021, 42 : 516 - 516
  • [5] Efficacy and Safety of Second and Third-Generation Laser Balloon for Paroxysmal Atrial Fibrillation Ablation Compared to Radiofrequency Ablation: A Matched-Cohort
    Guenancia, Charles
    Hammache, Nefissa
    Docq, Clemence
    Benali, Karim
    Hooks, Darren
    Echivard, Mathieu
    Pace, Nathalie
    Magnin-Poull, Isabelle
    de Chillou, Christian
    Sellal, Jean-Marc
    JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (12)
  • [6] An international multicentre experience with the third-generation laser balloon system: safety, efficiency, and efficacy
    Martignani, C.
    Bartoli, L.
    Spadotto, A.
    Tilz, R. R.
    Heeger, C. -H.
    Giaccardi, M.
    Miracapillo, G.
    Forleo, G. B.
    Schiavone, M.
    Giomi, A.
    Arena, G.
    Ciconte, G.
    Pappone, C.
    Montemerlo, E.
    Rovaris, G.
    EUROPEAN HEART JOURNAL, 2023, 44
  • [7] The Evaluation of Laser Weldability of the Third-Generation Advanced High Strength Steel
    Pereira, Antonio B.
    Santos, Rafael O.
    Carvalho, Bruno S.
    Butuc, Marilena C.
    Vincze, Gabriela
    Moreira, Luciano P.
    METALS, 2019, 9 (10)
  • [8] Single-sweep pulmonary vein isolation using the new third-generation laser balloon-Evolution in ablation style using endoscopic ablation system
    Tohoku, Shota
    Bordignon, Stefano
    Chen, Shaojie
    Zanchi, Simone
    Bianchini, Lorenzo
    Trolese, Luca
    Operhalski, Felix
    Urbanek, Lukas
    Chun, K. R. Julian
    Schmidt, Boris
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (11) : 2923 - 2932
  • [9] Effect of the Balloon Size on Lesion Formation During Visually Guided Laser Balloon Ablation in an In Vitro Model
    Matsunaga-Lee, Yasuharu
    Egami, Yasuyuki
    Nakamura, Hitoshi
    Matsuhiro, Yutaka
    Yasumoto, Koji
    Tsuda, Masaki
    Tanaka, Akihiro
    Okamoto, Naotaka
    Yano, Masamichi
    Shutta, Ryu
    Sakata, Yasushi
    Nishino, Masami
    Tanouchi, Jun
    CIRCULATION JOURNAL, 2021, 85 (08) : 1394 - 1399
  • [10] Validation of lesion durability following pulmonary vein isolation using the new third-generation laser balloon catheter in patients with recurrent atrial fibrillation
    Tohoku, Shota
    Bordignon, Stefano
    Chen, Shaojie
    Bologna, Fabrizio
    Urbanek, Lukas
    Operhalski, Felix
    Chun, K. R. Julian
    Schmidt, Boris
    JOURNAL OF CARDIOLOGY, 2021, 78 (05) : 388 - 396