Effect of left atrial volume and pulmonary vein anatomy on outcome of nMARQ™ catheter ablation of paroxysmal atrial fibrillation

被引:7
作者
Stabile, Giuseppe [1 ]
Anselmino, Matteo [2 ]
Soldati, Ezio [3 ]
De Ruvo, Ermengildo [4 ]
Solimene, Francesco [5 ]
Iuliano, Assunta [1 ]
Sciarra, Luigi [4 ]
Bongiorni, Maria Grazia [3 ]
Calo, Leonardo [4 ]
Gaita, Fiorenzo [2 ]
机构
[1] Clin Mediterranea, Naples, Italy
[2] Univ Turin, Dipartimento Sci Med, Turin, Italy
[3] Azienda Osped Univ Pisana, Pisa, Italy
[4] Policlin Casilino, Rome, Italy
[5] Clin Montevergine, Mercogliano, AV, Italy
关键词
Atrial fibrillation; Catheter ablation; Multielectrode ablation catheter; Anatomy; Safety; Midterm outcome; MAGNETIC-RESONANCE ANGIOGRAPHY; MANAGEMENT; EFFICACY; IMPACT; SAFETY; CRYOBALLOON; ESC;
D O I
10.1007/s10840-016-0189-3
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Purpose Left atrial volume (LA) and pulmonary vein (PV) anatomy may potentially relate to technical challenges in achieving stable and effective catheter position in case of atrial fibrillation (AF) ablation by means of "one-shot' catheters. The aim of this study was to investigate whether LA volume and PV anatomy, evaluated by computed tomography (CT) or magnetic resonance (MR) prior to ablation, predict acute and midterm outcome of AF ablation by nMARQ (TM). Methods We included 75 patients (mean age 58 +/- 11 years, 67 % male) with symptomatic paroxysmal AF. All patients underwent CT/MR scanning prior to catheter ablation to evaluate LA volume and PVanatomy. All the patients underwent PV isolation by nMARQ (TM), an open-irrigated mapping and radiofrequency (RF) decapolar ablation catheter. Ablation was guided by electroanatomic mapping allowing RF energy delivery in the antral region of PVs from ten irrigated electrodes simultaneously. Results Mean LA volume was 75 +/- 40 ml. A normal anatomy (4 PVs) was documented in 40 (53 %) patients and abnormal anatomy (common truncus or accessory PVs) in 35 patients. Mean procedural and fluoroscopy times were 94 +/- 55 and 8 +/- 5 min, respectively, without significant differences among patients with normal or abnormal anatomy (92 +/- 45 vs 95 +/- 64 min, p = 0.85 and 6 +/- 3 vs 8 +/- 4 min, p = 0.65, respectively). Mean ablation time was 14 +/- 3 min, and 99 % of the targeted veins were isolated with a mean of 23 +/- 5 RF pulses per patient. After a mean follow-up of 17 +/- 8 months, 23 (31 %) patients had an atrial arrhythmia recurrence. Neither LA volume nor PVanatomy was a predictor of outcome. Conclusions LA volume and PV anatomy did not affect procedural data and outcome in patients who underwent PV isolation by an open-irrigated mapping and RF decapolar ablation catheter.
引用
收藏
页码:201 / 207
页数:7
相关论文
共 26 条
[1]  
[Anonymous], J INTERV CARD ELECTR
[2]   Pulmonary veins branching pattern, assessed by magnetic resonance, does not affect transcatheter atrial fibrillation ablation outcome [J].
Anselmino, Matteo ;
Scaglione, Marco ;
Blandino, Alessandro ;
Beninati, Serena ;
Caponi, Domenico ;
Boffano, Carlo ;
Montefusco, Antonio ;
Cesarani, Federico ;
Gaita, Fiorenzo .
ACTA CARDIOLOGICA, 2010, 65 (06) :665-674
[3]   Morphologic Analysis of Left Atrial Anatomy by Magnetic Resonance Angiography in Patients With Atrial Fibrillation: A Large Single Center Experience [J].
Anselmino, Matteo ;
Blandino, Alessandro ;
Beninati, Serena ;
Rovera, Chiara ;
Boffano, Carlo ;
Belletti, Marco ;
Caponi, Domenico ;
Scaglione, Marco ;
Cesarani, Federico ;
Gaita, Fiorenzo .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (01) :1-7
[4]   Predictive value of early atrial tachyarrhythmias recurrence after circumferential anatomical pulmonary vein ablation [J].
Bertaglia, E ;
Stabile, G ;
Senatore, G ;
Zoppo, F ;
Turco, P ;
Amellone, C ;
De Simone, A ;
Fazzari, M ;
Pascotto, P .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2005, 28 (05) :366-371
[5]  
Calkins H, 2012, HEART RHYTHM, V9, P632, DOI 10.1016/j.hrthm.2011.12.016
[6]  
Camm AJ, 2012, EUROPACE, V14, P1385, DOI [10.1093/europace/eus305, 10.1093/eurheartj/ehs253]
[7]   Clinical Experience with a Single Catheter for Mapping and Ablation of Pulmonary Vein Ostium [J].
De Filippo, Paolo ;
He, Ding Sheng ;
Brambilla, Roberta ;
Gavazzi, Antonello ;
Cantu, Francesco .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (04) :367-373
[8]   Effect of Pulmonary Vein Anatomy and Left Atrial Dimensions on Outcome of Circumferential Radiofrequency Catheter Ablation for Atrial Fibrillation [J].
den Uijl, Dennis W. ;
Tops, Laurens F. ;
Delgado, Victoria ;
Schuijf, Joanne D. ;
Kroft, Lucia J. M. ;
de Roos, Albert ;
Boersma, Eric ;
Trines, Serge A. ;
Zeppenfeld, Katja ;
Schalij, Martin J. ;
Bax, Jeroen J. .
AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (02) :243-249
[9]   Acute Safety and Efficacy of a Novel Multipolar Irrigated Radiofrequency Ablation Catheter for Pulmonary Vein Isolation [J].
Deneke, Thomas ;
Schade, Anja ;
Mueller, Patrick ;
Schmitt, Rainer ;
Christopoulos, Georgios ;
Krug, Joachim ;
Szoelloesi, Geza ;
Muegge, Andreas ;
Kerber, Sebastian ;
Nentwich, Karin .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2014, 25 (04) :339-345
[10]   Pulmonary Vein Isolation Using a Visually Guided Laser Balloon Catheter: The First 200-Patient Multicenter Clinical Experience [J].
Dukkipati, Srinivas R. ;
Kuck, Karl-Heinz ;
Neuzil, Petr ;
Woollett, Ian ;
Kautzner, Josef ;
McElderry, H. Thomas ;
Schmidt, Boris ;
Gerstenfeld, Edward P. ;
Doshi, Shephal K. ;
Horton, Rodney ;
Metzner, Andreas ;
d'Avila, Andre ;
Ruskin, Jeremy N. ;
Natale, Andrea ;
Reddy, Vivek Y. .
CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2013, 6 (03) :467-472