SPECIATION OF CHROMIUM IN CAPSULES BY CAPILLARY ELECTROPHORESIS-INDUCTIVELY COUPLED PLASMA-MASS SPECTROMETRY

被引:5
作者
Lin, Li [1 ,2 ]
Zheng, JinPing [3 ]
Sun, JiHong [1 ]
机构
[1] Beijing Univ Technol, Beijing 100122, Peoples R China
[2] China Natl Food & Safety Supervis & Inspect Ctr, Yongfeng Ind Base, Beijing, Peoples R China
[3] Fuzhou Univ, Fuzhou 350002, Fujian, Peoples R China
关键词
Capillary electrophoresis; Chromium speciation; Gelatin capsules; Inductively coupled plasma-mass spectrometry; WATER SAMPLES; ION CHROMATOGRAPHY; ICP-MS; CR(VI); CR(III); TOXICITY; SELENIUM; CELLS;
D O I
10.1080/00032719.2014.908387
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A novel method for the determination of Cr(III) and Cr(VI) in gelatin capsules is reported that involved separation by capillary electrophoresis and the determination using inductively coupled plasma mass spectrometry with a collision-reaction cell. The separation was achieved on a fused-silica capillary column (75 mu m ID x 30 cm length). The electrophoretic buffer was 20 mM NaH2PO4-5 mM Na2B4O7 (pH 6.0) with an applied voltage of 15 kV. Chromium species in the capsules were extracted into a buffer-5 mM 1,2-cyclohexanediaminetetraacetic acid mixture. The spike recoveries of chromium species were in the range of 87% to 95%. The detection limits of Cr(III) and Cr(VI) were 0.61 and 0.45 ng.mL(-1), and the procedure was applied for the speciation of capsules. Approximately 0.242-71.64 mu g g(-1) of Cr(III) were detected in the capsules.
引用
收藏
页码:2406 / 2416
页数:11
相关论文
共 21 条
[1]   Chromium (VI) induced acute toxicity and genotoxicity in freshwater stinging catfish, Heteropneustes fossilis [J].
Ahmed, M. K. ;
Kundu, G. K. ;
Al-Mamun, M. H. ;
Sarkar, S. K. ;
Akter, M. S. ;
Khan, M. S. .
ECOTOXICOLOGY AND ENVIRONMENTAL SAFETY, 2013, 92 :64-70
[2]   Comparison of standard and reaction cell inductively coupled plasma mass spectrometry in the determination of chromium and selenium species by HPLC-ICP-MS [J].
Bednar, A. J. ;
Kirgan, R. A. ;
Jones, W. T. .
ANALYTICA CHIMICA ACTA, 2009, 632 (01) :27-34
[3]   Determination of chromium in water and urine by reaction cell inductively coupled plasma mass spectrometry [J].
Chang, YL ;
Jiang, SJ .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (12) :1434-1438
[4]   Interfacing flow injection with capillary electrophoresis and inductively coupled plasma mass spectrometry for Cr speciation in water samples [J].
Giné, MF ;
Gervasio, APG ;
Lavorante, AF ;
Miranda, CES ;
Carrilho, E .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2002, 17 (07) :736-738
[5]   Determination of chromium(III) and chromium(VI) using suppressed ion chromatography inductively coupled plasma mass spectrometry [J].
Gürleyük, H ;
Wallschläger, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2001, 16 (09) :926-930
[6]   APPLICATIONS OF CAPILLARY ELECTROPHORESIS IN ELEMENT SPECIATION ANALYSIS OF PLANT AND FOOD EXTRACTS [J].
HARMS, J ;
SCHWEDT, G .
FRESENIUS JOURNAL OF ANALYTICAL CHEMISTRY, 1994, 350 (1-2) :93-100
[7]   Speciation of chromium and vanadium in environmental samples using HPLC-DRC-ICP-MS [J].
Kuo, Chia-Yi ;
Jiang, Shiuh-Jen ;
Sahayam, A. C. .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2007, 22 (06) :636-641
[8]   Short-column CE coupled with inductively coupled plasma MS for high-throughput speciation analysis of chromium [J].
Li, Bao-Hui ;
Yan, Xiu-Ping .
ELECTROPHORESIS, 2007, 28 (09) :1393-1398
[9]   A high-efficiency cross-flow micronebulizer interface for capillary electrophoresis and inductively coupled plasma mass spectrometry [J].
Li, JX ;
Umemura, T ;
Odake, T ;
Tsunoda, K .
ANALYTICAL CHEMISTRY, 2001, 73 (24) :5992-5999
[10]   Capillary electrophoresis on-line coupled with hydride generation-atomic fluorescence spectrometry for speciation analysis of selenium [J].
Lu, CY ;
Yan, XP .
ELECTROPHORESIS, 2005, 26 (01) :155-160