Whole blood folate concentrations: Comparison between stratus folate (DADE) and radioassay (DPC) methods

被引:0
|
作者
BamontiCatena, F
Porcella, A
Pomati, M
Franzini, C
Rosina, M
Cavalca, V
Maiolo, AT
机构
[1] UNIV MILAN,OSPED L SACCO,IST SCI BIOMED,MILAN,ITALY
[2] UNIV MILAN,IRCCS,OSPED MAGGIORE,IST CHIRURG GEN & ONCOL CHIRURG,I-20122 MILAN,ITALY
[3] UNIV MILAN,IST CARDIOL,MILAN,ITALY
来源
EUROPEAN JOURNAL OF CLINICAL CHEMISTRY AND CLINICAL BIOCHEMISTRY | 1997年 / 35卷 / 10期
关键词
D O I
暂无
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
The analytical performance of the Stratus Folate assay for intra-erythrocyte folate determination in normal subjects and in patients affected by folate-related diseases was compared with that of the radioassay (DPC) routinely employed by us. Folate concentrations were measured in freshly obtained EDTA whole blood from 100 subjects. Haemolysis was performed with the appropriate lysis reagent. In addition, to compare two different haemolysis procedures folate determination was carried out in 51 samples haemolysed according to the two procedures in parallel. Data were analyzed using Wilcoxon's test and standardized principal component analysis. Stratus Folate assay and radioassay performances were comparable in terms of analytical characteristics as well as in individual intraerythrocyte folate values across the range of whole blood concentrations examined in the survey. Significant differences were detected between the two different haemolysis procedures only for the radioassay. In conclusion, we observed no significant differences between the two folate determination methods despite their different analytical principles, which indicates the suitability of routine use of the automated non-isotopic Stratus Folate assay for clinical purposes. Moreover, with the latter assay the laboratory staff could choose the more convenient haemolysis procedure.
引用
收藏
页码:781 / 785
页数:5
相关论文
共 50 条
  • [1] A comparison of methods for the determination of whole blood folate
    Clifford, AJ
    Dueker, SR
    Lin, Y
    Jones, AD
    Mercer, RS
    Miller, JW
    Green, R
    FASEB JOURNAL, 2000, 14 (04): : A243 - A243
  • [2] FOLATE ASSAY - COMPARISON OF RADIOASSAY AND MICROBIOLOGICAL METHODS
    SHANE, B
    TAMURA, T
    STOKSTAD, ELR
    CLINICA CHIMICA ACTA, 1980, 100 (01) : 13 - 19
  • [3] FOLATE LEVELS IN FOOD - COMPARISON OF MICROBIOLOGICAL ASSAY AND RADIOASSAY METHODS FOR MEASURING FOLATE
    RUDDICK, JE
    VANDERSTOEP, J
    RICHARDS, JF
    JOURNAL OF FOOD SCIENCE, 1978, 43 (04) : 1238 - 1241
  • [4] Relationship between plasma folate concentrations measured by radioassay and L. casei assay methods.
    Morgan, SL
    Baggott, JE
    Johnston, KE
    Tamura, T
    FASEB JOURNAL, 1999, 13 (04): : A229 - A229
  • [5] Serum cotinine and whole blood folate concentrations in pregnancy
    Prasodjo, Adila
    Pfeiffer, Christine M.
    Fazili, Zia
    Xu, Yingying
    Liddy, Stacey
    Yolton, Kimberly
    Savitz, David A.
    Lanphear, Bruce P.
    Braun, Joseph M.
    ANNALS OF EPIDEMIOLOGY, 2014, 24 (07) : 498 - 503
  • [6] COMPARISON OF FOLATE-I-125 RADIOASSAY WITH MICROBIOLOGICAL ASSAY FOR DETERMINING SERUM FOLATE
    BATRA, KK
    HAIDER, M
    GROSS, D
    CLINICAL CHEMISTRY, 1975, 21 (07) : 1029 - 1030
  • [7] EFFECTIVE QUALITY-CONTROL OF FOLATE RADIOASSAY METHODS
    DOETSCH, K
    MANGIARDI, V
    LEWIN, N
    CLINICAL CHEMISTRY, 1977, 23 (06) : 1139 - 1140
  • [8] VALIDATION OF A RADIOASSAY FOR THE DETERMINATION OF SERUM FOLATE AND COBALAMIN CONCENTRATIONS IN DOGS
    BATT, RM
    MCLEAN, L
    RUTGERS, HC
    HALL, EJ
    JOURNAL OF SMALL ANIMAL PRACTICE, 1991, 32 (05) : 221 - 224
  • [9] RESULTS WITH COMMERCIAL RADIOASSAY KITS COMPARED WITH MICROBIOLOGICAL ASSAY OF FOLATE IN SERUM AND WHOLE-BLOOD
    MCGOWN, EL
    LEWIS, CM
    DONG, MH
    SAUBERLICH, HE
    CLINICAL CHEMISTRY, 1978, 24 (12) : 2186 - 2191
  • [10] Whole-blood folate values in subjects with different methylenetetrahydrofolate reductase genotypes: Differences between the radioassay and microbiological assays
    Molloy, AM
    Mills, JL
    Kirke, PN
    Whitehead, AS
    Weir, DG
    Scott, JM
    CLINICAL CHEMISTRY, 1998, 44 (01) : 186 - 188