Electrochemical detection of uric acid and ascorbic acid: Application in serum

被引:56
作者
Choukairi, M. [1 ]
Bouchta, D. [1 ]
Bounab, L. [1 ]
Ben Atyah, M. [1 ]
Elkhamlichi, R. [1 ]
Chaouket, F. [1 ]
Raissouni, I. [1 ]
Rodriguez, I. N. [2 ]
机构
[1] Univ Abdelmalek Essaadi, Dept Chem, Lab Electrochem & Interfacial Syst ERESI, Fac Sci, Tetouan 93002, Morocco
[2] Univ Cadiz, Fac Sci, Dept Analyt Chem, Cadiz, Spain
关键词
Uric acid; Ascorbic acid; Serum; Sonogel-carbon; L-Cysteine; GLASSY-CARBON ELECTRODE; VOLTAMMETRIC DETERMINATION; AMPEROMETRIC DETECTION; DOPAMINE; PASTE; NANOPARTICLES; OXIDATION; SAMPLES; SENSOR;
D O I
10.1016/j.jelechem.2015.10.012
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The detection and quantification of uric acid (UA) and ascorbic acid (AA) in different biological fluids such as serum is very important in clinical diagnosis. In this study, a sonogel-carbon electrode modified with L-cysteine was used for detection and quantification of these molecules by cyclic voltammetry (CV) and square wave voltammetry (SWV). These two methods are known for their suitability for monitoring of bioactive molecules in biological samples. Optimization of parameters affecting selectivity and sensitivity of these two methods is included. The peak current showed a linear relationship with the concentrations of UA and AA in the range of 10(-5) M to 10(-4) M for UA and 5 x 10(-5) M respectively. The detection limit was of 10(-5) M for UA and 5 x 10(-5) M for AA. In addition, the interference of UA and AA was also studied. A neat separation of the oxidation peaks of these two compounds with a peak-to-peak separation of 295 mV was registered. The results indicate that carbon electrode modified with L-cysteine can successfully be used for a selective and sensitive simultaneous determination of UA and AA in the serum. (C) 2015 Elsevier B.V. All rights reserved.
引用
收藏
页码:117 / 124
页数:8
相关论文
共 50 条
[31]   Selective voltammetric and amperometric detection of uric acid with oxidized diamond film electrodes [J].
Popa, E ;
Kubota, Y ;
Tryk, DA ;
Fujishima, A .
ANALYTICAL CHEMISTRY, 2000, 72 (07) :1724-1727
[32]   Separation and simultaneous determination of uric acid and ascorbic acid on a dynamically modified poly(dimethylsiloxane) microchip [J].
Qiu, Jianding ;
Hu, Pengfei ;
Liang, Ruping .
ANALYTICAL SCIENCES, 2007, 23 (12) :1409-1414
[33]   Simultaneous voltammetric measurement of ascorbic acid, epinephrine and uric acid at a glassy carbon electrode modified with caffeic acid [J].
Ren, W ;
Luo, HQ ;
Li, NB .
BIOSENSORS & BIOELECTRONICS, 2006, 21 (07) :1086-1092
[34]  
Retna C.R., 2003, J ELECTROANAL CHEM, V540, P69
[35]  
Ruffien-Ciszark A., 2005, THESIS
[36]   Simultaneous determination of dopamine, ascorbic acid, and uric acid using carbon ionic liquid electrode [J].
Safavi, Afsaneh ;
Maleki, Norouz ;
Moradlou, Omran ;
Tajabadi, Fariba .
ANALYTICAL BIOCHEMISTRY, 2006, 359 (02) :224-229
[37]   Simultaneous detection of ascorbic acid, uric acid and homovanillic acid at copper modified electrode [J].
Selvaraju, T. ;
Ramaraj, R. .
ELECTROCHIMICA ACTA, 2007, 52 (09) :2998-3005
[38]   Simultaneous voltammetric detection of ascorbic acid and uric acid at a carbon-paste modified electrode incorporating thionine-nafion ion-pair as an electron mediator [J].
Shahrokhian, S ;
Ghalkhani, M .
ELECTROCHIMICA ACTA, 2006, 51 (13) :2599-2606
[39]   Modification of carbon paste with congo red supported on multi-walled carbon nanotube for voltammetric determination of uric acid in the presence of ascorbic acid [J].
Shahrokhian, Saeed ;
Zare-Mehrjardi, Hamid Reza ;
Khajehsharifi, Habibollah .
JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2009, 13 (10) :1567-1575
[40]   Electrochemical sensor for simultaneous detection of ascorbic acid, uric acid and xanthine based on the surface enhancement effect of mesoporous silica [J].
Sun, Dong ;
Zhang, Yu ;
Wang, Fengran ;
Wu, Kangbing ;
Chen, Jianwei ;
Zhou, Yikai .
SENSORS AND ACTUATORS B-CHEMICAL, 2009, 141 (02) :641-645