Relating the pore size distribution of ultrafiltration membranes to dextran rejection

被引:57
作者
Wickramasinghe, S. Ranil [1 ]
Bower, Shane E. [1 ]
Chen, Zhen [1 ]
Mukherjee, Abhik [1 ]
Husson, Scott M. [2 ]
机构
[1] Colorado State Univ, Dept Biol & Chem Engn, Ft Collins, CO 80523 USA
[2] Clemson Univ, Dept Chem & Biomol Engn, Clemson, SC 29634 USA
关键词
Dextran; Log-normal distribution; Molecular weight cutoff; Rejection; Ultrafiltration; GRADED COLLODION MEMBRANES; FILTRATION MEMBRANES; SIEVING MEMBRANES; TRANSPORT; PROTEINS; MOLECULES; SURFACE; FICOLL;
D O I
10.1016/j.memsci.2009.04.056
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The rejection of various molecular weight dextrans for two commercially available regenerated cellulose and one polyethersulfone membrane has been investigated. Experimentally determined rejection curves were compared to calculated rejection curves based on field-emission scanning electron microscopy imaging assuming that the membrane pore size distribution may be described by the log-normal distribution function. Results show relatively good agreement between calculated and experimental curves; however, the calculated curves generally predict a broader rejection curve. At lower rejection values, the actual rejection is less than calculated. Results also indicate that field-emission scanning electron microscopy, a routinely used imaging technique, may be used to estimate the rejection curve for a membrane, thus enabling more informed selection of an appropriate membrane for a given separation. The results of this work are relevant to ultrafiltration, which is used in the biotechnology industry for protein concentration and buffer exchange. The success of a given UF operation depends on efficient passage or rejection of the desired solute species in solution. (C) 2009 Elsevier B.V. All rights reserved.
引用
收藏
页码:1 / 8
页数:8
相关论文
共 32 条
[31]   USE OF THE LOG-NORMAL PROBABILITY DENSITY-FUNCTION TO ANALYZE MEMBRANE PORE-SIZE DISTRIBUTIONS - FUNCTIONAL FORMS AND DISCREPANCIES [J].
ZYDNEY, AL ;
AIMAR, P ;
MEIRELES, M ;
PIMBLEY, JM ;
BELFORT, G .
JOURNAL OF MEMBRANE SCIENCE, 1994, 91 (03) :293-298
[32]   Improving dextran tests for ultrafiltration membranes: Effect of device format [J].
Zydney, Andrew L. ;
Xenopoulos, Alex .
JOURNAL OF MEMBRANE SCIENCE, 2007, 291 (1-2) :180-190