Does load-bearing materials influence hip capsule thickness in total hip replacement? An MRI case-matched study

被引:3
|
作者
Odri, Guillaume-Anthony [1 ]
Sanchez, Julien [2 ]
Sverzut, Jean-Michel [2 ]
Laredo, Jean-Denis [2 ]
Sedel, Laurent [1 ]
Bizot, Pascal [1 ]
机构
[1] Hop Lariboisiere, Assistance Publ Hop Paris, Serv Chirurg Orthoped, 4 Rue Ambroise Pare, F-75010 Paris, France
[2] Hop Lariboisiere, Assistance Publ Hop Paris, Serv Radiol Osteoarticulaire, 4 Rue Ambroise Pare, F-75010 Paris, France
关键词
Total hip replacement; Dislocation; Hip capsule; Bearings;
D O I
10.1016/j.otsr.2019.08.023
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Ceramic-on-ceramic (COC) total hip replacements (THR) have exhibited less instability and late dislocation. Hip capsule plays an important role in hip stability. Different surrounding soft tissue reactions have been observed according to the bearing material used but no study compared these data using MRI investigation. Therefore, we performed a retrospective case control study to compare hip capsule thicknesses according to the bearing materials in THR and in native hips. Hypothesis: Hip capsule is thicker after COC THR compared to ceramicor metal-on-polyethylene (PE) bearings, or native hips. Materials and method: Magnetic resonance imaging (MRI) images, combined with a multi acquisition variable resonance image combination (MAVRIC) sequence, was used to measure the hip capsule thickness in 16 patients (29 hips) who had either COC (13 hips, median age at surgery: 64.8 years old, median follow-up at imaging: 2482 days), PE bearings (11 hips, median age at surgery: 48.4 years old (significantly different from COC THR), median follow-up at imaging: 1860 days (NS)), or a native hip with no implant (5 hips). Two independent radiologists measured capsular thicknesses in 4 different zones and were blinded regarding the bearing components. The imaged hips were classified into three groups: native, COC and PE. Results: The COC THR group had the thickest capsules (median 7.0 mm, range 2.9-15.5 mm). This result was statistically significant (p < 0.0001) when compared to PE THR (median 4.9 mm, range 2.2-10.5 mm), and to native hips (median 4.1 mm, range 2.7-6.9 mm) measurements, respectively. Furthermore, painful hips had thinner capsules (4.6 mm, range 2-10.5) compared to not painful hips (6.8 mm, range 2.3-15.5) (p = 0.0006). Discussion: This is the first in-vivo study measuring capsular thickness in THR with the objective of measuring variations according to the hip implant materials used. The results revealed a significantly thicker capsule for the COC bearing compared to either PE or native hips, and a thinner capsule in painful hips. (C) 2019 Elsevier Masson SAS. All rights reserved.
引用
收藏
页数:6
相关论文
共 35 条
  • [1] Total hip replacement in patients with hip fracture: A matched cohort study
    Anakwe, Raymond E.
    Middleton, Scott D.
    Jenkins, Paul J.
    Butler, Alison P.
    Aitken, Stuart A.
    Keating, John F.
    Moran, Matthew
    JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2012, 73 (03) : 738 - 742
  • [2] Revision total hip arthroplasty in deficient proximal femur using a distal load-bearing prosthesis
    Suominen, S
    Santavirta, S
    ANNALES CHIRURGIAE ET GYNAECOLOGIAE, 1996, 85 (03) : 253 - 262
  • [3] Outcome analysis of various bearing surface materials used in total hip replacement
    Chen, Long
    Xing, Fei
    Wang, Yuanzheng
    He, Rui
    He, Jingming
    Xu, Yunwen
    Wang, Cheng
    Li, Zhuhai
    Sun, Zeyu
    Li, Yankun
    Yang, Jiaqi
    Kong, Lingchao
    Li, Yangyang
    Sun, Li
    MATERIALS EXPRESS, 2020, 10 (03) : 301 - 313
  • [4] The Effect of Obesity on the Clinical, Functional and Radiological Outcome of Cementless Total Hip Replacement: A Case-Matched Study With a Minimum 10-Year Follow-Up
    Tai, Stephen M.
    Imbuldeniya, Arjuna M.
    Munir, Selin
    Walter, William L.
    Walter, William K.
    Zicat, Bernard A.
    JOURNAL OF ARTHROPLASTY, 2014, 29 (09) : 1758 - 1762
  • [5] Total hip replacement in morbidly obese patients with osteoarthritis RESULTS OF A PROSPECTIVELY MATCHED STUDY
    Chee, Y. H.
    Teoh, K. H.
    Sabnis, B. M.
    Ballantyne, J. A.
    Brenkel, I. J.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2010, 92B (08): : 1066 - 1071
  • [6] Matched cohort study of topical tranexamic acid in cementless primary total hip replacement
    Sanz-Reig J.
    Mas Martinez J.
    Verdu Román C.
    Morales Santias M.
    Martínez Gimenez E.
    Bustamante Suarez de Puga D.
    European Journal of Orthopaedic Surgery & Traumatology, 2018, 28 (7) : 1335 - 1339
  • [7] A Prospective Metal Ion Study of Large-Head Metal-on-Metal Bearing: A Matched-Pair Analysis of Hip Resurfacing Versus Total Hip Replacement
    Beaule, Paul E.
    Kim, Paul R.
    Hamdi, Amre
    Fazekas, Anna
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 2011, 42 (02) : 251 - +
  • [8] Does crutch length influence gait parameters after total hip replacement surgery?
    Freddolini, Marco
    Esposito, Francesco
    Marcucci, Massimiliano
    Corvi, Andrea
    Braccio, Palmina
    Latella, Leonardo
    GAIT & POSTURE, 2018, 60 : 262 - 267
  • [9] Resurfacing hip replacement and cemented total hip replacement have equivalent outcome at one year in a disease matched population: a case-control study of patient reported outcome measures
    Ray, Robbie
    Goudie, Ewan B.
    Jenkins, Paul
    Gaston, Paul
    HIP INTERNATIONAL, 2013, 23 (04) : 373 - 379
  • [10] Does the order of total hip replacement and lumbar spinal stenosis surgery influence patient-reported outcomes: An observational register study
    Eneqvist, Ted
    Bulow, Erik
    Nemes, Szilard
    Brisby, Helena
    Fritzell, Peter
    Rolfson, Ola
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2021, 39 (05) : 998 - 1006