Challenges and limitations of patient-specific vascular phantom fabrication using 3D Polyjet printing

被引:117
作者
Ionita, Ciprian N.
Mokin, Maxim
Varble, Nicole
Bednarek, Daniel R.
Xiang, Jianping
Snyder, Kenneth V.
Siddiqui, Adnan H.
Levy, Elad I.
Meng, Hui
Rudin, Stephen
机构
来源
MEDICAL IMAGING 2014: BIOMEDICAL APPLICATIONS IN MOLECULAR, STRUCTURAL, AND FUNCTIONAL IMAGING | 2014年 / 9038卷
关键词
Vascular phantoms; 3D printing; additive manufacturing; patient specific phantoms; CT; Cone-Beam CT; ANEURYSMS;
D O I
10.1117/12.2042266
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Additive manufacturing (3D printing) technology offers a great opportunity towards development of patient-specific vascular anatomic models, for medical device testing and physiological condition evaluation. However, the development process is not yet well established and there are various limitations depending on the printing materials, the technology and the printer resolution. Patient-specific neuro-vascular anatomy was acquired from computed tomography angiography and rotational digital subtraction angiography (DSA). The volumes were imported into a Vitrea 3D workstation (Vital Images Inc.) and the vascular lumen of various vessels and pathologies were segmented using a "marching cubes" algorithm. The results were exported as Stereo Lithographic (STL) files and were further processed by smoothing, trimming, and wall extrusion (to add a custom wall to the model). The models were printed using a Polyjet printer, Eden 260V (Objet-Stratasys). To verify the phantom geometry accuracy, the phantom was reimaged using rotational DSA, and the new data was compared with the initial patient data. The most challenging part of the phantom manufacturing was removal of support material. This aspect could be a serious hurdle in building very tortuous phantoms or small vessels. The accuracy of the printed models was very good: distance analysis showed average differences of 120 m between the patient and the phantom reconstructed volume dimensions. Most errors were due to residual support material left in the lumen of the phantom. Despite the post-printing challenges experienced during the support cleaning, this technology could be a tremendous benefit to medical research such as in device development and testing.
引用
收藏
页数:12
相关论文
共 17 条
[1]   A multimodality vascular imaging phantom of an abdominal aortic aneurysm with a visible thrombus [J].
Allard, Louise ;
Soulez, Gilles ;
Chayer, Boris ;
Qin, Zhao ;
Roy, David ;
Cloutier, Guy .
MEDICAL PHYSICS, 2013, 40 (06)
[2]  
[Anonymous], 2000, Handbook of Medical Imaging
[3]  
[Anonymous], 2009, Computed Tomography: Principles, Design Artifacts and Recent Advances
[4]   Aneurysm Rupture Following Treatment with Flow-Diverting Stents: Computational Hemodynamics Analysis of Treatment [J].
Cebral, J. R. ;
Mut, F. ;
Raschi, M. ;
Scrivano, E. ;
Ceratto, R. ;
Lylyk, P. ;
Putman, C. M. .
AMERICAN JOURNAL OF NEURORADIOLOGY, 2011, 32 (01) :27-33
[5]  
CloudCompare, 3D point cloud and mesh processing software
[6]   Heart Disease and Stroke Statistics-2013 Update A Report From the American Heart Association [J].
Go, Alan S. ;
Mozaffarian, Dariush ;
Roger, Veronique L. ;
Benjamin, Emelia J. ;
Berry, Jarett D. ;
Borden, William B. ;
Bravata, Dawn M. ;
Dai, Shifan ;
Ford, Earl S. ;
Fox, Caroline S. ;
Franco, Sheila ;
Fullerton, Heather J. ;
Gillespie, Cathleen ;
Hailpern, Susan M. ;
Heit, John A. ;
Howard, Virginia J. ;
Huffman, Mark D. ;
Kissela, Brett M. ;
Kittner, Steven J. ;
Lackland, Daniel T. ;
Lichtman, Judith H. ;
Lisabeth, Lynda D. ;
Magid, David ;
Marcus, Gregory M. ;
Marelli, Ariane ;
Matchar, David B. ;
McGuire, Darren K. ;
Mohler, Emile R. ;
Moy, Claudia S. ;
Mussolino, Michael E. ;
Nichol, Graham ;
Paynter, Nina P. ;
Schreiner, Pamela J. ;
Sorlie, Paul D. ;
Stein, Joel ;
Turan, Tanya N. ;
Virani, Salim S. ;
Wong, Nathan D. ;
Woo, Daniel ;
Turner, Melanie B. .
CIRCULATION, 2013, 127 (01) :E6-E245
[7]   Cost-Effectiveness Analysis of Endovascular Versus Open Surgical Repair of Acute Abdominal Aortic Aneurysms Based on Worldwide Experience [J].
Hayes, Paul D. ;
Sadat, Umar ;
Walsh, Stewart R. ;
Noorani, Ayesha ;
Tang, Tjun Y. ;
Bowden, David J. ;
Gillard, Jonathan H. ;
Boyle, Jonathan R. .
JOURNAL OF ENDOVASCULAR THERAPY, 2010, 17 (02) :174-182
[8]   Microangiographic image guided localization of a new asymmetric stent for treatment of cerebral aneurysms [J].
Ionita, CN ;
Rudin, S ;
Hoffmann, KR ;
Bednarek, DR .
Medical Imaging 2005: Visualization, Image-Guided Procedures, and Display, Pts 1 and 2, 2005, 5744 :354-365
[9]   Particle image velocimetry (PIV) evaluation of flow modification in aneurysm phantoms using asymmetric stents [J].
Ionita, CN ;
Hoi, Y ;
Meng, H ;
Rudin, S .
MEDICAL IMAGING 2004: PHYSIOLOGY, FUNCTION, AND STRUCTURE FROM MEDICAL IMAGES, 2004, 5 (23) :295-306
[10]  
Ionita CN, 2011, MEDICAL IMAGING 2011, V7965