Automated laser registration in image-guided surgery:: evaluation of the correlation between laser scan resolution and navigation accuracy

被引:43
作者
Marmulla, R
Lüth, T
Mühling, J
Hassfeld, S
机构
[1] Univ Heidelberg, Dept Craniomaxillofacial Surg, D-69120 Heidelberg, Germany
[2] Charite Univ Med Berlin, Dept Craniomaxillofacial Surg Navigat & Robot, Berlin, Germany
关键词
laser scan; surface registration; image-guided surgery; cranio-maxillofacial surgery; surgical segment navigator;
D O I
10.1016/j.ijom.2004.01.005
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Markerless patient registration based on the facial skin surface makes logistics prior to image-guided surgery much easier, as it is not necessary to place and measure registration markers. A laser scan registration of the surgical site takes the place of conventional marker-based registration. In a clinical study, the stability and accuracy of markerless patient registration was evaluated in 12 patients. Intraoral titanium markers served as targets for the infrared-pointer of the navigation system in order to check the accuracy of the markerless registration process. The correlation between laser scan resolution and navigation accuracy was checked using seven different laser scan resolutions (a cloud of 300,000 laser scan points down to 3750 laser scan points of the surgical site). The markerless patient registration was successful as long as high laser scan resolution was used (30,000 laser scan points and more): the titanium markers were detected with a mean deviation of 1.1 +/- 0.2 mm. Low resolution laser scans (6000 laser scan points of the surgical site and less) revealed inaccuracies up to 6 mm.
引用
收藏
页码:642 / 648
页数:7
相关论文
共 15 条
[1]  
Bucholz R, 2000, Stud Health Technol Inform, V70, P39
[2]  
Burkart A, 2001, Comput Aided Surg, V6, P270, DOI 10.3109/10929080109146092
[3]   Comparison of six three-dimensional navigation systems during sinus surgery [J].
Cartellieri, M ;
Vorbeck, F ;
Kremser, J .
ACTA OTO-LARYNGOLOGICA, 2001, 121 (04) :500-504
[4]   Identifying the position of an ear from a laser scan: The significance for planning rehabilitation [J].
Coward, TJ ;
Scott, BJJ ;
Watson, RM ;
Richards, R .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2002, 31 (03) :244-251
[5]   ADVANCES IN INTERACTIVE CRANIOFACIAL SURGERY PLANNING BY 3D SIMULATION AND VISUALIZATION [J].
GIROD, S ;
KEEVE, E ;
GIROD, B .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 1995, 24 (01) :120-125
[6]   CLINICAL USE OF A FRAMELESS STEREOTAXIC ARM - RESULTS OF 325 CASES [J].
GOLFINOS, JG ;
FITZPATRICK, BC ;
SMITH, LR ;
SPETZLER, RF .
JOURNAL OF NEUROSURGERY, 1995, 83 (02) :197-205
[7]   Novel methods for quantifying soft tissue changes after orthognathic surgery [J].
Guest, E ;
Berry, E ;
Morris, D .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2001, 30 (06) :484-489
[8]  
HASSFELD S, 1995, INT J ORAL MAX SURG, V24, P111
[9]   AN ACCURATE AND ERGONOMIC METHOD OF REGISTRATION FOR IMAGE-GUIDED NEUROSURGERY [J].
HENDERSON, JM ;
SMITH, KR ;
BUCHOLZ, RD .
COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1994, 18 (04) :273-277
[10]   Robotics and coronary artery surgery [J].
Magee, MJ ;
Mack, MJ .
CURRENT OPINION IN CARDIOLOGY, 2002, 17 (06) :602-607