A physiologically representative in vitro model of the coronary circulation

被引:46
作者
Geven, MCF
Bohté, VN
Aarnoudse, WH
van den Berg, PMJ
Rutten, MCM
Pijls, NHJ
van de Vosse, FN
机构
[1] Eindhoven Univ Technol, Dept Biomed Engn, NL-5600 MB Eindhoven, Netherlands
[2] Catharina Hosp, Dept Cardiol, NL-5602 ZA Eindhoven, Netherlands
关键词
coronary circulation; in vitro model; coronary flow; coronary pressure;
D O I
10.1088/0967-3334/25/4/009
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
With the development of clinical diagnostic techniques to investigate the coronary circulation in conscious humans, the in vitro validation of such newly developed techniques is of major importance. The aim of this study was to develop an in vitro model that is able to mimic the coronary circulation in such a way that coronary pressure and flow signals under baseline as well as hyperaemic conditions are approximated as realistically as possible and are in accordance with recently gained insights into such signals in conscious man. In the present in vitro model the heart, the systemic and coronary circulation are modelled on the basis of the elements of a lumped parameter mathematical model only consisting of elements that can be represented by segments in an experimental set-up. A collapsible tube, collapsed by the ventricular pressure, represents the variable resistance and volume behaviour of the endocardial part of the myocardium. The pressure and flow signals obtained are similar to physiological human coronary pressure and flow, both for baseline and hyperaemic conditions. The model allows for in vitro evaluation of clinical diagnostic techniques.
引用
收藏
页码:891 / 904
页数:14
相关论文
共 19 条
[1]   Myocardial resistance assessed by guidewire-based pressure-temperature measurement: In vitro validation [J].
Aarnoudse, W ;
van den Berg, P ;
van de Vosse, F ;
Geven, M ;
Rutten, M ;
van Turnhout, M ;
Fearon, W ;
De Bruyne, B ;
Pijls, N .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 62 (01) :56-63
[2]   INTERACTION BETWEEN INTRAMYOCARDIAL PRESSURE (IMP) AND MYOCARDIAL CIRCULATION [J].
ARTS, T ;
RENEMAN, RS .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1985, 107 (01) :51-56
[3]   MODEL OF THE CORONARY CIRCULATION BASED ON PRESSURE-DEPENDENCE OF CORONARY RESISTANCE AND COMPLIANCE [J].
BRUINSMA, P ;
ARTS, T ;
DANKELMAN, J ;
SPAAN, JAE .
BASIC RESEARCH IN CARDIOLOGY, 1988, 83 (05) :510-524
[4]   INHIBITION OF CORONARY BLOOD-FLOW BY A VASCULAR WATERFALL MECHANISM [J].
DOWNEY, JM ;
KIRK, ES .
CIRCULATION RESEARCH, 1975, 36 (06) :753-760
[5]   Novel index for invasively assessing the coronary microcirculation [J].
Fearon, WF ;
Balsam, LB ;
Farouque, HMO ;
Robbins, RC ;
Fitzgerald, PJ ;
Yock, PG ;
Yeung, AC .
CIRCULATION, 2003, 107 (25) :3129-3132
[6]   CAN CORONARY SYSTOLIC-DIASTOLIC FLOW DIFFERENCES BE PREDICTED BY LEFT-VENTRICULAR PRESSURE OR TIME-VARYING INTRAMYOCARDIAL ELASTNCE [J].
KRAMS, R ;
VANHAELST, ACTA ;
SIPKEMA, P ;
WESTERHOF, N .
BASIC RESEARCH IN CARDIOLOGY, 1989, 84 (02) :149-159
[7]   VARYING ELASTANCE CONCEPT MAY EXPLAIN CORONARY SYSTOLIC FLOW IMPEDIMENT [J].
KRAMS, R ;
SIPKEMA, P ;
WESTERHOF, N .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (05) :H1471-H1479
[8]   CONTRACTILITY IS THE MAIN DETERMINANT OF CORONARY SYSTOLIC FLOW IMPEDIMENT [J].
KRAMS, R ;
SIPKEMA, P ;
ZEGERS, J ;
WESTERHOF, N .
AMERICAN JOURNAL OF PHYSIOLOGY, 1989, 257 (06) :H1936-H1944
[9]   THE CORONARY CIRCULATION [J].
MATES, RE .
JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 1993, 115 (04) :558-561
[10]   In vitro study of FFR, QCA, and IVUS for the assessment of optimal stent deployment [J].
Matthys, K ;
Carlier, S ;
Segers, P ;
Ligthart, J ;
Sianos, G ;
Serrano, P ;
Verdonck, PR ;
Serruys, PW .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2001, 54 (03) :363-375