Effectiveness of subcutaneous implantable cardioverter-defibrillator testing in patients with hypertrophic cardiomyopathy

被引:25
作者
Maurizi, Niccolo [1 ,9 ]
Tanini, Ilaria [1 ]
Olivotto, Iacopo [1 ]
Amendola, Ernesto [2 ]
Limongelli, Giuseppe [2 ]
Losi, Maria Angela [3 ]
Allocca, Giuseppe [4 ]
Perego, Giovanni Battista [5 ]
Pieragnoli, Paolo [6 ]
Ricciardi, Giuseppe [6 ]
De Filippo, Paolo [7 ]
Ferrari, Paola [7 ]
Quarta, Giovanni [7 ]
Viani, Stefano [8 ]
Rapacciuolo, Antonio [3 ]
Bongiorni, Maria Grazia [8 ]
Cecchi, Franco [9 ]
机构
[1] Univ Hosp Careggi, Referral Ctr Cardiomyopathies, Florence, Italy
[2] AO Colli Monaldi Hosp, Naples, Italy
[3] Federico II Univ Hosp, Adv Biomed Sci, Naples, Italy
[4] Conegliano Gen Hosp, Conegliano, Italy
[5] Ist Auxol, Milan, Italy
[6] Univ Hosp Careggi, Florence, Italy
[7] ASST Papa Giovanni XXIII, Bergamo, Italy
[8] Univ Hosp Pisa, Pisa, Italy
[9] Fdn ARCARD, Florence, Italy
关键词
S-ICD; Hypertrophic cardiomyopathy; Sudden death prevention; CARDIOVASCULAR MAGNETIC-RESONANCE; LEFT-VENTRICULAR MASS; TASK-FORCE; THERAPY; COMPLICATIONS; EFFORTLESS; GUIDELINES; DIAGNOSIS; IDE;
D O I
10.1016/j.ijcard.2016.12.187
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Subcutaneous ICD (S-ICD) is a promising option for Hypertrophic Cardiomyopathy (HCM) patients at risk of Sudden Cardiac Death (SCD). However, its effectiveness in terminating ventricular arrhythmias in HCM is yet unresolved. Methods: Consecutive HCM patients referred for S-ICD implantation were prospectively enrolled. Patients underwent one or two attempts of VF induction by the programmer. Successful conversion was defined as any 65 J shock that terminated VF (not requiring rescue shocks). Clinical and instrumental parameterswere analyzed to study predictors of conversion failure. Results: Fifty HCMpatients (34males, 40 +/- 16 years) with amean BMI of 25.2 +/- 4.4 kg/m(2) were evaluated. Mean ESC SCD risk of was 6.5 +/- 3.9% and maximal LV wall thickness (LVMWT) was 26 +/- 6 mm. In 2/50 patients no arrhythmias were inducible, while in 7 (14%) only sustained ventricular tachycardia was induced and cardioverted. In the remaining 41 (82%) patients, 73 VF episodes were induced (1 episode in 14 and > 1 in 27 patients). Of these, 4 (6%) spontaneously converted. In 68/69 (98%) the S-ICD successfully cardioverted, but failed in 1 (2%) patient, who needed rescue defibrillation. This patient was severely obese (BMI 36) and LVMWT of 25 mm. VF was re-induced and successfully converted by the 80 J reversed polarity S-ICD. Conclusions: Acute DT at 65 J at the implant showed the effectiveness of S-ICD in the recognition and termination of VT/VF in all HCM patients except one. Extreme LVH did not affect the performance of the device, whereas severe obesity was likely responsible for the single 65 J failure. (C) 2017 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:115 / 119
页数:5
相关论文
共 20 条
[1]   An Entirely Subcutaneous Implantable Cardioverter-Defibrillator [J].
Bardy, Gust H. ;
Smith, Warren M. ;
Hood, Margaret A. ;
Crozier, Ian G. ;
Melton, Iain C. ;
Jordaens, Luc ;
Theuns, Dominic ;
Park, Robert E. ;
Wright, David J. ;
Connelly, Derek T. ;
Fynn, Simon P. ;
Murgatroyd, Francis D. ;
Sperzel, Johannes ;
Neuzner, Joerg ;
Spitzer, Stefan G. ;
Ardashev, Andrey V. ;
Oduro, Amo ;
Boersma, Lucas ;
Maass, Alexander H. ;
Van Gelder, Isabelle C. ;
Wilde, Arthur A. ;
van Dessel, Pascal F. ;
Knops, Reinoud E. ;
Barr, Craig S. ;
Lupo, Pierpaolo ;
Cappato, Riccardo ;
Grace, Andrew A. .
NEW ENGLAND JOURNAL OF MEDICINE, 2010, 363 (01) :36-44
[2]   Risk Factors for Implantable Defibrillator Lead Fracture in a Recalled and a Nonrecalled Lead [J].
Ben Morrison, T. ;
Rea, Robert F. ;
Hodge, David O. ;
Crusan, Daniel ;
Koestler, Celeste ;
Asirvatham, Samuel J. ;
Bradley, David ;
Shen, Win K. ;
Munger, Thomas M. ;
Hammill, Stephen C. ;
Friedman, Paul A. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (06) :671-677
[3]   A Primer on Arrhythmias in Patients with Hypertrophic Cardiomyopathy [J].
Bockstall, Katy E. ;
Link, Mark S. .
CURRENT CARDIOLOGY REPORTS, 2012, 14 (05) :552-562
[4]   A New Algorithm to Reduce Inappropriate Therapy in the S-ICD System [J].
Brisben, Amy J. ;
Burke, Martin C. ;
Knight, Bradley P. ;
Hahn, Stephen J. ;
Herrmann, Keith L. ;
Allavatam, Venugopal ;
Mahajan, Deepa ;
Sanghera, Rick ;
Gold, Michael R. .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2015, 26 (04) :417-423
[5]   Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator 2-Year Results From a Pooled Analysis of the IDE Study and EFFORTLESS Registry [J].
Burke, Martin C. ;
Gold, Michael R. ;
Knight, Bradley P. ;
Barr, Craig S. ;
Theuns, Dominic A. M. J. ;
Boersma, Lucas V. A. ;
Knops, Reinoud E. ;
Weiss, Raul ;
Leon, Angel R. ;
Herre, John M. ;
Husby, Michael ;
Stein, Kenneth M. ;
Lambiase, Pier D. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2015, 65 (16) :1605-1615
[6]   2014 ESC Guidelines on diagnosis and management of hypertrophic cardiomyopathy The Task Force for the Diagnosis and Management of Hypertrophic Cardiomyopathy of the European Society of Cardiology (ESC) [J].
Elliott, Perry M. ;
Anastasakis, Aris ;
Borger, Michael A. ;
Borggrefe, Martin ;
Cecchi, Franco ;
Charron, Philippe ;
Hagege, Albert Alain ;
Lafont, Antoine ;
Limongelli, Giuseppe ;
Mahrholdt, Heiko ;
McKenna, William J. ;
Mogensen, Jens ;
Nihoyannopoulos, Petros ;
Nistri, Stefano ;
Pieper, Petronella G. ;
Pieske, Burkert ;
Rapezzi, Claudio ;
Rutten, Frans H. ;
Tillmanns, Christoph ;
Watkins, Hugh .
EUROPEAN HEART JOURNAL, 2014, 35 (39) :2733-+
[7]   Intermuscular pocket for subcutaneous implantable cardioverter defibrillator: Single-center experience [J].
Ferrari, Paola ;
Giofre, Fabrizio ;
De Filippo, Paolo .
JOURNAL OF ARRHYTHMIA, 2016, 32 (03) :223-226
[8]  
Gersh BJ, 2011, CIRCULATION, V124, P2761, DOI 10.1161/CIR.0b013e318223e230
[9]   Evaluation of subcutaneous ICD early performance in hypertrophic cardiomyopathy from the pooled EFFORTLESS and IDE cohorts [J].
Lambiase, Pier D. ;
Gold, Michael R. ;
Hood, Margaret ;
Boersma, Lucas ;
Theuns, Dominic A. M. J. ;
Burke, Martin C. ;
Weiss, Raul ;
Russo, Andrea M. ;
Kaab, Stefan ;
Knight, Bradley P. .
HEART RHYTHM, 2016, 13 (05) :1066-1074
[10]   Hypertrophic Cardiomyopathy Present and Future, With Translation Into Contemporary Cardiovascular Medicine [J].
Maron, Barry J. ;
Ommen, Steve R. ;
Semsarian, Christopher ;
Spirito, Paolo ;
Olivotto, Iacopo ;
Maron, Martin S. .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2014, 64 (01) :83-99