Using Ultrasound Backscattering Signals and Nakagami Statistical Distribution to Assess Regional Cataract Hardness

被引:44
作者
Caixinha, Miguel [1 ]
Jesus, Danilo A. [1 ]
Velte, Elena [2 ]
Santos, Mario J. [1 ]
Santos, Jaime B. [1 ]
机构
[1] Univ Coimbra, Dept Elect & Comp Engn, P-3030790 Coimbra, Portugal
[2] Univ Coimbra, Dept Phys, P-3030790 Coimbra, Portugal
关键词
Backscattering; cataract hardness; Nakagami distribution; ultrasound; NEEDLE TRANSDUCER; IN-VITRO; LENS; MODEL; EYE; ATTENUATION; CLASSIFIERS; PARAMETERS; SCATTERING; IMAGES;
D O I
10.1109/TBME.2014.2335739
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
This study aims to analyze the protein aggregates spatial distribution for different cataract degrees, and correlate this information with the lens acoustical parameters and by this way, assess the cataract regional hardness. Different cataract degrees were induced ex vivo in porcine lenses. A 25 MHz ultrasonic transducer was used to obtain the acoustical parameters (velocity, attenuation, and backscattering signals). B-scan and Nakagami images were constructed. Also, lenses with different cataract degrees were sliced in two regions (nucleus and cortex), for fibers and collagen detection. A significant increase with cataract formation was found for the velocity, attenuation, and brightness intensity of the B-scan images and Nakagami m parameter (p < 0.01). The acoustical parameters showed a good to moderate correlation with the m parameter for the different stages of cataract formation. A strong correlation was found between the protein aggregates in the cortex and the m parameter. Lenses without cataract are characterized using a classification and regression tree, by a mean brightness intensity <= 0.351, a variance of the B-scan brightness intensity <= 0.070, a velocity <= 1625 m/s, and an attenuation <= 0.415 dB/mm.MHz (sensitivity: 100% and specificity: 72.6%). To characterize different cataract degrees, the m parameter should be considered. Initial stages of cataract are characterized by a mean brightness intensity >0.351 and a variance of the m parameter >0.110. Advanced stages of cataract are characterized by a mean brightness intensity >0.351, a variance of the m parameter <= 0.110, and a mean m parameter >0.374. For initial and advanced stages of cataract, a sensitivity of 78.4% and a specificity of 86.5% are obtained.
引用
收藏
页码:2921 / 2929
页数:9
相关论文
共 34 条
  • [1] Carricondo P., 2010, ARQUIVOS BRASILEIROS, V73, P7
  • [2] RELATION BETWEEN LOCAL ACOUSTIC PARAMETERS AND PROTEIN DISTRIBUTION IN HUMAN AND PORCINE EYE LENSES
    DEKORTE, CL
    VANDERSTEEN, AFW
    THIJSSEN, JM
    DUINDAM, JJ
    OTTO, C
    PUPPELS, GJ
    [J]. EXPERIMENTAL EYE RESEARCH, 1994, 59 (05) : 617 - 627
  • [3] Crystallin proteins and amyloid fibrils
    Ecroyd, H.
    Carver, John A.
    [J]. CELLULAR AND MOLECULAR LIFE SCIENCES, 2009, 66 (01) : 62 - 81
  • [4] Using ultrasound Nakagami imaging to assess liver fibrosis in rats
    Ho, Ming-Chih
    Lin, Jen-Jen
    Shu, Yu-Chen
    Chen, Chiung-Nien
    Chang, King-Jen
    Chang, Chien-Cheng
    Tsui, Po-Hsiang
    [J]. ULTRASONICS, 2012, 52 (02) : 215 - 222
  • [5] Determining the acoustic properties of the lens using a high-frequency ultrasonic needle transducer
    Huang, Chih-Chung
    Zhou, Qifa
    Ameri, Hossein
    Wu, DaWei
    Sun, Lei
    Wang, Shyh-Hau
    Humayun, Mark S.
    Shung, K. Kirk
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (12) : 1971 - 1977
  • [6] Evaluation of lens hardness in cataract surgery using high-frequency ultrasonic parameters in vitro
    Huang, Chih-Chung
    Ameri, Hossein
    DeBoer, Charles
    Rowley, Adrian P.
    Xu, Xiaochen
    Sun, Lei
    Wang, Shyh-Hau
    Humayun, Mark S.
    Shung, K. Kirk
    [J]. ULTRASOUND IN MEDICINE AND BIOLOGY, 2007, 33 (10) : 1609 - 1616
  • [7] Measurements of attenuation coefficient for evaluating the hardness of a cataract lens by a high-frequency ultrasonic needle transducer
    Huang, Chih-Chung
    Chen, Ruimin
    Tsui, Po-Hsiang
    Zhou, Qifa
    Humayun, Mark S.
    Shung, K. Kirk
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (19) : 5981 - 5994
  • [8] Kanski J., 2007, CLIN DIAGNOSIS OPTHA
  • [9] Ultrasonic spectrum analysis for tissue evaluation
    Lizzi, FL
    Feleppa, EJ
    Alam, SK
    Deng, CX
    [J]. PATTERN RECOGNITION LETTERS, 2003, 24 (4-5) : 637 - 658
  • [10] A system for preoperative stratification of cataract patients according to risk of intraoperative complications: a prospective analysis of 1441 cases
    Muhtaseb, M
    Kalhoro, A
    Ionides, A
    [J]. BRITISH JOURNAL OF OPHTHALMOLOGY, 2004, 88 (10) : 1242 - 1246