Diagnosis of Medium Voltage Cables for Nuclear Power Plant

被引:1
|
作者
Ha, Che-Wung [1 ]
Lee, Do Hwan [1 ]
机构
[1] KHNP Cent Res Inst, Adv Reactors Dev Lab, Licensing Team APR1400, Taejon, South Korea
关键词
High frequency partial discharge; Medium voltage cable; Nuclear power plant;
D O I
10.5370/JEET.2014.9.4.1369
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan delta measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.
引用
收藏
页码:1369 / 1374
页数:6
相关论文
共 50 条
  • [41] Voltage Rise Mitigation in Medium-Voltage Networks with Long Underground Cables and Low Power Demand
    Cetkovic, Deni
    Zutolija, Josip
    Komen, Vitomir
    ENERGIES, 2024, 17 (13)
  • [42] Determination of Trap Distribution Based on Voltage Response Measurement for Condition Monitoring of Nuclear Power Plant I&C Cables
    Tamus, Zoltan Adam
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73
  • [43] Dielectric loss and extended voltage response measurements for low-voltage power cables used in nuclear power plant: potential methods for aging detection due to thermal stress
    Mustafa, Ehtasham
    Afia, Ramy S. A.
    Tamus, Zoltan Adam
    ELECTRICAL ENGINEERING, 2021, 103 (02) : 899 - 908
  • [44] A Review of Partial Discharge Detection, Diagnosis Techniques in High Voltage Power Cables
    Refaat, Shady S.
    Shams, Mohammed A.
    PROCEEDINGS 2018 IEEE 12TH INTERNATIONAL CONFERENCE ON COMPATIBILITY, POWER ELECTRONICS AND POWER ENGINEERING (CPE-POWERENG 2018), 2018,
  • [45] On site PD-diagnosis of power cables using the oscillating voltage method
    Petzold, F.
    Beigert, M.
    Gulski, Edward
    ESMO 2006-2006 IEEE 11th International Conference on Transmission & Distribution Construction, Operation and Live-Line Maintenance, 2006, : 194 - 200
  • [46] Dielectric loss and extended voltage response measurements for low-voltage power cables used in nuclear power plant: potential methods for aging detection due to thermal stress
    Ehtasham Mustafa
    Ramy S. A. Afia
    Zoltán Ádám Tamus
    Electrical Engineering, 2021, 103 : 899 - 908
  • [47] Partial discharge monitoring in medium voltage cables
    Zhou, Chengke
    Hepburn, Donald M.
    Michel, Mattheiu
    Song, Xiaodi
    Zhang, Guobin
    PROCEEDINGS OF 2008 INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS, 2007, : 1021 - +
  • [48] On-Site Diagnostic Tests on Medium Voltage, XLPE-Insulated Power Cables
    Abou Dakka, Mahmoud
    Bulinski, Alexander
    Bamji, Soli
    2008 IEEE POWER & ENERGY SOCIETY GENERAL MEETING, VOLS 1-11, 2008, : 3019 - 3024
  • [49] Testing of Medium Voltage Cables Cross-linked polyethylene cables
    Kment, Attila
    Pipa, Marek
    Halan, Igor
    Ruhnke, Thorsten
    PROCEEDINGS OF THE 8TH INTERNATIONAL SCIENTIFIC SYMPOSIUM ON ELECTRICAL POWER ENGINEERING (ELEKTROENERGETIKA 2015), 2015, : 304 - 306
  • [50] Research on Treeing Retardant Performance and Test Protocol of Medium Voltage XLPE Power Cables
    Xu Lin-hua
    Yang Li-ming
    Yan Meng-kun Yan
    2008 CHINA INTERNATIONAL CONFERENCE ON ELECTRICITY DISTRIBUTION, VOLS 1 AND 2, 2009, : 338 - 341