Most accidents of medium-voltage cables installed in nuclear power plants result from the initial defect of internal insulators or the initial failure due to poor construction. However, as the service years of plants increase, the possibility of cable accidents is also rapidly increases. This is primarily caused by electric, mechanical, thermal, and radiation stresses. Recently, much attention is paid to the study of cable diagnoses. To date, partial discharge and Tan delta measurements are known as reliable methods to diagnose the aging of medium-voltage cables. High frequency partial discharge measurement techniques have been widely used to diagnose cables in transmission and distribution systems. However, the on-line high frequency partial discharge technique has not been used in the nuclear power plants because of the plant shutdown risk, degraded measurement sensitivity, and application problems. In this paper, the partial discharge measurement with a portable device was tried to evaluate the integrity of the 4.16kV and 13.8kV cable lines. The test results show that the high detection sensitivity can be achieved by the high frequency partial discharge technique. The present technique is highly attractive to diagnose medium voltage cables in nuclear power plants.
引用
收藏
页码:1369 / 1374
页数:6
相关论文
共 50 条
  • [21] Insulation deterioration diagnosis on ultra high voltage power cables
    Byun, DG
    Shin, HT
    Kim, WJ
    Shin, JY
    Hong, JW
    PROCEEDINGS OF THE 7TH INTERNATIONAL CONFERENCE ON PROPERTIES AND APPLICATIONS OF DIELECTRIC MATERIALS, VOLS 1-3, 2003, : 179 - 182
  • [22] Analysis of armor grounding methods in medium voltage underground power cables
    Kara, Serhat
    Alboyaci, Bora
    Ozyesil, Ahmet
    JOURNAL OF POLYTECHNIC-POLITEKNIK DERGISI, 2022, 25 (04): : 1587 - 1594
  • [23] Power line communication in medium voltage systems:: Characterization of MV cables
    Cataliotti, Antonio
    Daidone, Alfredo
    Tine, Giovanni
    IEEE TRANSACTIONS ON POWER DELIVERY, 2008, 23 (04) : 1896 - 1902
  • [24] SILANE CROSSLINKED INSULATION FOR MEDIUM-VOLTAGE POWER-CABLES
    CURRAT, C
    WIRE JOURNAL INTERNATIONAL, 1984, 17 (06): : 60 - 65
  • [25] SILANE CROSSLINKED INSULATION FOR MEDIUM-VOLTAGE POWER-CABLES
    HOCHSTRASSER, U
    WIRE JOURNAL INTERNATIONAL, 1983, 16 (09): : 42 - 42
  • [26] A Medium-Voltage Cables Model for Power-Line Communication
    Cataliotti, Antonio
    Daidone, Alfredo
    Tine, Giovanni
    IEEE TRANSACTIONS ON POWER DELIVERY, 2009, 24 (01) : 129 - 135
  • [27] Simulation of Partial Discharge Location in Medium-Voltage Power Cables
    Liang, Keng-Wei
    Lee, Chang-Hsing
    Chiu, Min-Yen
    Fan, Chen-Li
    Yu-Chih
    Lin
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 655 - 658
  • [28] Life-assessment technique for nuclear power plant cables
    Bartonicek, B
    Hnat, V
    Placek, V
    RADIATION PHYSICS AND CHEMISTRY, 1998, 52 (1-6): : 639 - 642
  • [29] Evaluation of Accelerated Ageing Cables Used in Nuclear Power Plant
    Lee, Sang-hwa
    Lee, Jae-do
    Kim, Moon-young
    Jang, Hong-seok
    Jeong, Choong-heui
    PROCEEDINGS OF 2012 IEEE INTERNATIONAL CONFERENCE ON CONDITION MONITORING AND DIAGNOSIS (IEEE CMD 2012), 2012, : 681 - 684
  • [30] Evaluation of accelerated ageing cables used in nuclear power plant
    Instrumentation and Control and Electrical System Evaluation Department, Korea Institute of Nuclear Safety, Daejeon, Korea, Republic of
    Proc. IEEE Int. Conf. Cond. Monit. Diagn., CMD, (681-684):