Validity of Consumer-Based Physical Activity Monitors

被引:274
作者
Lee, Jung-Min [1 ]
Kim, Youngwon [2 ]
Welk, Gregory J. [2 ]
机构
[1] Univ Nebraska, Sch Hlth Phys Educ & Recreat, Omaha, NE 68182 USA
[2] Iowa State Univ, Dept Kinesiol, Ames, IA USA
关键词
VALIDATION; ACTIVITY MONITOR; PHYSICAL ACTIVITY; ENERGY EXPENDITURE; ENERGY-EXPENDITURE; ACTIGRAPH ACCELEROMETERS; VALIDATION; CHILDREN; RELIABILITY; WALKING; ADULTS;
D O I
10.1249/MSS.0000000000000287
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
Background: Many consumer-based monitors are marketed to provide personal information on the levels of physical activity and daily energy expenditure (EE), but little or no information is available to substantiate their validity. Purpose: This study aimed to examine the validity of EE estimates from a variety of consumer-based, physical activity monitors under free-living conditions. Methods: Sixty (26.4 +/- 5.7 yr) healthy males (n = 30) and females (n = 30) wore eight different types of activity monitors simultaneously while completing a 69-min protocol. The monitors included the BodyMedia FIT armband worn on the left arm, the DirectLife monitor around the neck, the Fitbit One, the Fitbit Zip, and the ActiGraph worn on the belt, as well as the Jawbone Up and Basis B1 Band monitor on the wrist. The validity of the EE estimates from each monitor was evaluated relative to criterion values concurrently obtained from a portable metabolic system (i.e., Oxycon Mobile). Differences from criterion measures were expressed as a mean absolute percent error and were evaluated using 95% equivalence testing. Results: For overall group comparisons, the mean absolute percent error values (computed as the average absolute value of the group-level errors) were 9.3%, 10.1%, 10.4%, 12.2%, 12.6%, 12.8%, 13.0%, and 23.5% for the BodyMedia FIT, Fitbit Zip, Fitbit One, Jawbone Up, ActiGraph, DirectLife, NikeFuel Band, and Basis B1 Band, respectively. The results from the equivalence testing showed that the estimates from the BodyMedia FIT, Fitbit Zip, and NikeFuel Band (90% confidence interval = 341.1-359.4) were each within the 10% equivalence zone around the indirect calorimetry estimate. Conclusions: The indicators of the agreement clearly favored the BodyMedia FIT armband, but promising preliminary findings were also observed with the Fitbit Zip.
引用
收藏
页码:1840 / 1848
页数:9
相关论文
共 24 条
[1]   Validity and reliability issues in objective monitoring of physical activity [J].
Bassett, DR .
RESEARCH QUARTERLY FOR EXERCISE AND SPORT, 2000, 71 (02) :S30-S36
[2]   Validity of four motion sensors in measuring moderate intensity physical activity [J].
Bassett, DR ;
Ainsworth, BE ;
Swartz, AM ;
Strath, SJ ;
O'Brien, WL ;
King, GA .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2000, 32 (09) :S471-S480
[3]   Estimation of Free-Living Energy Expenditure Using a Novel Activity Monitor Designed to Minimize Obtrusiveness [J].
Bonomi, Alberto G. ;
Plasqui, Guy ;
Goris, Annelies H. C. ;
Westerterp, Klass R. .
OBESITY, 2010, 18 (09) :1845-1851
[4]   Validation of the SenseWear Pro Armband Algorithms in Children [J].
Calabro, Miguel A. ;
Welk, Gregory J. ;
Eisenmann, Joey C. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2009, 41 (09) :1714-1720
[5]   Validation of Pattern-Recognition Monitors in Children Using Doubly Labeled Water [J].
Calabro, Miguel Andres ;
Stewart, Jeanne M. ;
Welk, Gregory J. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (07) :1313-1322
[6]   Best practice methods to apply to measurement of resting metabolic rate in adults: A systematic review [J].
Compher, Charlene ;
Frankenfield, David ;
Keim, Nancy ;
Roth-Yousey, Lori .
JOURNAL OF THE AMERICAN DIETETIC ASSOCIATION, 2006, 106 (06) :881-903
[7]   Refined Two-Regression Model for the ActiGraph Accelerometer [J].
Crouter, Scott E. ;
Kuffel, Erin ;
Haas, Jere D. ;
Frongillo, Edward A. ;
Bassett, David R., Jr. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2010, 42 (05) :1029-1037
[8]   A Comparison of Energy Expenditure Estimation of Several Physical Activity Monitors [J].
Dannecker, Kathryn L. ;
Sazonova, Nadezhda A. ;
Melanson, Edward L. ;
Sazonov, Edward S. ;
Browning, Raymond C. .
MEDICINE AND SCIENCE IN SPORTS AND EXERCISE, 2013, 45 (11) :2105-2112
[9]   A statistical test to show negligible trend [J].
Dixon, PM ;
Pechmann, JHK .
ECOLOGY, 2005, 86 (07) :1751-1756
[10]   Validation of the SenseWear Armband at high intensity exercise [J].
Drenowatz, Clemens ;
Eisenmann, Joey C. .
EUROPEAN JOURNAL OF APPLIED PHYSIOLOGY, 2011, 111 (05) :883-887