Confocal 3D Optical Intraoral Scanners and Comparison of Image Capturing Accuracy

被引:27
作者
Amornvit, Pokpong [1 ]
Rokaya, Dinesh [1 ]
Peampring, Chaimongkon [1 ]
Sanohkan, Sasiwimol [1 ]
机构
[1] Prince Songkla Univ, Fac Dent, Dept Prosthet Dent, Hat Yai 90110, Songkhla, Thailand
来源
CMC-COMPUTERS MATERIALS & CONTINUA | 2021年 / 66卷 / 01期
关键词
Confocal; intraoral scanners; accuracy; 3-dimensional analysis; teeth analysis; digital;
D O I
10.32604/cmc.2020.011943
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Several capture techniques are used in intraoral optical scanners in the dental market, such as Triangulation (Cerec Omnicam, Dentsply Sirona), Activewave front sampling (3M ESPE) and confocal technology (iTero, Align). The accuracy of intraoral scanners is the most significant focal point for developers to research. This in-vitro study studied the accuracy of confocal scanners launched from 2015-2020 (Trios 3, Trios 4, iTero Element; 3Shape Trios A/S, Copenhagen, Denmark, and iTero Element2, and iTero Element5D; Align Technologies, San Jose, CA, USA). A 3D printing model modified from the American National Standard No. 132 was scanned five times each scanner. Both Trios3 and Trios4 were scanned using regular scan mode (N) and high-resolution mode (HR). All scanning methods followed the recommendations from the manufacturers. Then the digital models were exported and saved as STL files. Various measurements were determined in the digital model from each scan using Rhinoceros 3D Software (Rhino, Robert McNeel & Associates for Windows, Washington DC, USA). Measurements from the 3D printed model were used as control. All data were recorded in Microsoft Excel and then transferred to SPSS. Descriptive statistics were recorded. Multiple comparisons of various measurements were made among the different scanners and with the control using One-way ANOVA and post hoc using Sheffe (p < 0.01). The surface area in the X and Y axis ranged from 2-60 mm, while the depth (Z-axis) ranged from 2-8 mm. The Trios and iTero families showed similar accuracy. However, for the diagonal, the Trios series showed better results compared with the iTero series. Within the same brand, different versions showed no significant change regarding accuracy.
引用
收藏
页码:303 / 314
页数:12
相关论文
共 28 条
  • [21] The current clinical relevancy of intraoral scanners in implant dentistry
    Sawase, Takashi
    Kuroshima, Shinichiro
    [J]. DENTAL MATERIALS JOURNAL, 2020, 39 (01) : 57 - 61
  • [22] Fast CU size decision and mode decision algorithm for intra prediction in HEVC
    Song, Yun
    Zeng, Ye
    Li, Xueyu
    Cai, Biye
    Yang, Gaobo
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2017, 76 (02) : 2001 - 2017
  • [23] Progress in digital dentistry: The practical use of intraoral scanners
    Suese, Kazuhiko
    [J]. DENTAL MATERIALS JOURNAL, 2020, 39 (01) : 52 - 56
  • [24] Materials in digital dentistry-A review
    Sulaiman, Taiseer A.
    [J]. JOURNAL OF ESTHETIC AND RESTORATIVE DENTISTRY, 2020, 32 (02) : 171 - 181
  • [25] Use of digital impression systems with intraoral scanners for fabricating restorations and fixed dental prostheses
    Takeuchi, Yoshimasa
    Koizumi, Hiroyasu
    Furuchi, Mika
    Sato, Yohei
    Ohkubo, Chikahiro
    Matsumura, Hideo
    [J]. JOURNAL OF ORAL SCIENCE, 2018, 60 (01) : 1 - 7
  • [26] An Advanced Deep Residual Dense Network (DRDN) Approach for Image Super-Resolution
    Wang Wei
    Jiang Yongbin
    Luo Yanhong
    Li Ji
    Wang Xin
    Zhang Tong
    [J]. INTERNATIONAL JOURNAL OF COMPUTATIONAL INTELLIGENCE SYSTEMS, 2019, 12 (02) : 1592 - 1601
  • [27] A Novel Image Classification Approach via Dense-MobileNet Models
    Wang, Wei
    Li, Yutao
    Zou, Ting
    Wang, Xin
    You, Jieyu
    Luo, Yanhong
    [J]. MOBILE INFORMATION SYSTEMS, 2020, 2020
  • [28] A robust forgery detection algorithm for object removal by exemplar-based image inpainting
    Zhang, Dengyong
    Liang, Zaoshan
    Yang, Gaobo
    Li, Qingguo
    Li, Leida
    Sun, Xingming
    [J]. MULTIMEDIA TOOLS AND APPLICATIONS, 2018, 77 (10) : 11823 - 11842