Analysis of the Ampacity Characteristic of Single-Core AC Cable Laid in Water

被引:0
|
作者
Ding Shuchun [1 ]
Jian Ganyang [1 ]
Liu Gang [1 ]
Lei Chenghua [1 ]
机构
[1] South China Univ Technol, Sch Elect Power, Guangzhou 510640, Guangdong, Peoples R China
关键词
110kV cable; ampacity; external thermal resistance; core temperature; water; test;
D O I
暂无
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Cable conductor temperature is an important parameter to determine the cable ampacity. On the other hand, the surrounding condition has a tremendous influence on cable conductor temperature. In order to improve the operating current of cable, this article derivates the calculation formulae for the ampacity of single-core AC cable laid in water, by analyzing the operating current characteristics of the single-core AC cable laid on water. The further correctness of the theoretical analysis is demonstrated by the comparison of the experimental statistics of conductor temperature of the single-core AC cables respectively immersed in water and in air without being exposed to the sunlight. It also draw a conclusion that AC cable laid on water can maximize the cable ampacity, and provide important theoretical basis to maximize the cable ampacity.
引用
收藏
页数:4
相关论文
共 50 条
  • [21] Hot spot temperature inversion for the single-core power cable joint
    Ruan, Jiang-jun
    Liu, Chao
    Huang, Dao-chun
    Zhan, Qing-hua
    Tang, Lie-Zheng
    APPLIED THERMAL ENGINEERING, 2016, 104 : 146 - 152
  • [22] Size analysis of single-core magnetic nanoparticles
    Ludwig, Frank
    Balceris, Christoph
    Viereck, Thilo
    Posth, Oliver
    Steinhoff, Uwe
    Gavilan, Helena
    Costo, Rocio
    Zeng, Lunjie
    Olsson, Eva
    Jonasson, Christian
    Johansson, Christer
    JOURNAL OF MAGNETISM AND MAGNETIC MATERIALS, 2017, 427 : 19 - 24
  • [23] Working temperature calculation of single-core cable by nonlinear finite element method
    Meng, Xiaokai
    Han, Peijie
    Liu, Yongxin
    Lu, Zhumao
    Jin, Tao
    ARCHIVES OF ELECTRICAL ENGINEERING, 2019, 68 (03) : 643 - 656
  • [24] Solution of Steady-State Thermal Conditions of Single-Core Insulated Conductors Laid in Groups.
    Slaninka, Pavel
    Elektrotechnicky obzor, 1980, 69 (01): : 3 - 7
  • [25] Current reduction factor of compensation conductors laid alongside three single-core cables in flat formation
    Sarajcev, I
    Majstrovic, M
    Medic, I
    2003 IEEE International Symposium on Electromagnetic Compatibility (EMC), Vols 1 and 2, Symposium Record, 2003, : 1020 - 1023
  • [26] Characteristic phase generated carrier technology for the single-core fiber optic sensing
    Xiao, Qian
    Jia, Bo
    Wu, Yuan
    Bian, Pang
    Yi Qi Yi Biao Xue Bao/Chinese Journal of Scientific Instrument, 2014, 35 (01): : 36 - 42
  • [27] MATHEMATICAL-ANALYSIS OF SURGE PERFORMANCE OF 3-PHASE, SINGLE-CORE CABLE SYSTEM WITH CROSSBONDED SHEATHS
    TANAKA, I
    ELECTRICAL ENGINEERING IN JAPAN, 1973, 93 (06) : 79 - 86
  • [28] Determination of the reduction factor for feeding cable lines consisting of three single-core cables
    Popovic, LM
    IEEE TRANSACTIONS ON POWER DELIVERY, 2003, 18 (03) : 736 - 743
  • [29] Research on the insulation on-line monitoring of single-core XPLE cable metal sheath
    CEEE, Huazhong University of Science and Technology, Wuhan 430074, China
    Gaoya Dianqi, 2006, 2 (90-92):
  • [30] A Parameter Estimation Technique for the Semi-conducting Layers in Single-core XLPE Cable
    Zhang, Wei
    Li, Hong-Jie
    Liu, Chongxin
    Yang, Yuqi
    Huang, Zhiwei
    Xue, Rong
    IEEE TRANSACTIONS ON DIELECTRICS AND ELECTRICAL INSULATION, 2014, 21 (04) : 1916 - 1925