Minimizing color interference from biological samples in optode-based measurements

被引:17
作者
Ahuja, Punkaj [1 ]
Peshkova, Maria A. [1 ,2 ]
Hemphill, Brian D. [1 ]
Gratzl, Miklos [1 ]
机构
[1] Case Western Reserve Univ, Dept Biomed Engn, Cleveland, OH 44106 USA
[2] St Petersburg State Univ, Dept Phys Chem, St Petersburg 198504, Russia
关键词
Optode membrane; Sample color interference; White beads; LED light source; Monochrome camera; PLATE-FORMAT OPTODE; OPTICAL SENSORS; ELECTROLYTES; CARE; HUE;
D O I
10.1016/j.snb.2014.07.113
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Optodes contain an ionophore, chromoionophore, and lipophilic anion in a plasticized membrane. The chromoionophore has a neutral and a protonated form with partially overlapping absorption peaks. The ratio of these forms determines the color of the optode membrane, which depends on the ratio of the activities of protons and the ion that the ionophore is selective for in the sample. In most physiolog fluids, sodium is well buffered and the color of a pH/Na+ optode depends predominantly on pH alone. However, colored samples can interfere with the measurement. We explore suppression of color interference by using white beads immobilized in a hydrogel layer between the sample and the optode membrane, and TiO2 nanoparticles dispersed within the optode membrane in reflectance based measurements. Both reduce color interference to very low levels, but the latter approach leads to more stable color response. Other physical interferences in optode-based measurements are due to instability in illumination, and partial overlap of the absorption peaks. Both problems are addressed here using a set of red, green and blue narrow-band LEDs and grayscale CCD detector, as opposed to a color camera with white illumination. LED-illuminated and color-insulated optodes remove substantial hurdles that stood in the way of biomedical and other applications of this technology. (C) 2014 Elsevier B. V. All rights reserved.
引用
收藏
页码:319 / 325
页数:7
相关论文
共 22 条
[1]   Inkjet-printed microfluidic multianalyte chemical sensing paper [J].
Abe, Koji ;
Suzuki, Koji ;
Citterio, Daniel .
ANALYTICAL CHEMISTRY, 2008, 80 (18) :6928-6934
[2]  
[Anonymous], 2005, FRONTIERS CHEM SENSO
[3]   Carrier-based ion-selective electrodes and bulk optodes. 1. General characteristics [J].
Bakker, E ;
Buhlmann, P ;
Pretsch, E .
CHEMICAL REVIEWS, 1997, 97 (08) :3083-3132
[4]   Use of the Hue Parameter of the Hue, Saturation, Value Color Space As a Quantitative Analytical Parameter for Bitonal Optical Sensors [J].
Cantrell, K. ;
Erenas, M. M. ;
de Orbe-Paya, I. ;
Capitan-Vallvey, L. F. .
ANALYTICAL CHEMISTRY, 2010, 82 (02) :531-542
[5]  
Cox CJ, 2001, CLIN LAB MED, V21, P321
[6]   Use of digital reflection devices for measurement using hue-based optical sensors [J].
Erenas, M. M. ;
Cantrell, K. ;
Ballesta-Claver, J. ;
de Orbe-Paya, I. ;
Capitan-Vallvey, L. F. .
SENSORS AND ACTUATORS B-CHEMICAL, 2012, 174 :10-17
[7]   Polymethacrylate optodes: A potential for chemical digital color analysis [J].
Gavrilenko, Natalya A. ;
Muravyov, Sergey V. ;
Silushkin, Stanislav V. ;
Spiridonova, Anna S. .
MEASUREMENT, 2014, 51 :464-469
[8]  
Gratzl M., UNPUB
[9]   Microtiter plate-format optode [J].
Kim, SB ;
Cho, HC ;
Cha, GS ;
Nam, H .
ANALYTICAL CHEMISTRY, 1998, 70 (22) :4860-4863
[10]   Quantitative determination of heparin levels in serum with microtiter plate-format optode [J].
Kim, SB ;
Kang, TY ;
Cha, GS ;
Nam, H .
ANALYTICA CHIMICA ACTA, 2006, 557 (1-2) :117-122