MRI-Only Based Radiotherapy Treatment Planning for the Rat Brain on a Small Animal Radiation Research Platform (SARRP)

被引:15
作者
Gutierrez, Shandra [1 ]
Descamps, Benedicte [1 ]
Vanhove, Christian [1 ]
机构
[1] Univ Ghent, iMinds Med IT Dept, Med Image & Signal Proc Grp, B-9000 Ghent, Belgium
关键词
DOSE CALCULATIONS; SIMULATION;
D O I
10.1371/journal.pone.0143821
中图分类号
O [数理科学和化学]; P [天文学、地球科学]; Q [生物科学]; N [自然科学总论];
学科分类号
07 ; 0710 ; 09 ;
摘要
Computed tomography (CT) is the standard imaging modality in radiation therapy treatment planning (RTP). However, magnetic resonance (MR) imaging provides superior soft tissue contrast, increasing the precision of target volume selection. We present MR-only based RTP for a rat brain on a small animal radiation research platform (SARRP) using probabilistic voxel classification with multiple MR sequences. Six rat heads were imaged, each with one CT and five MR sequences. The MR sequences were: T1-weighted, T2-weighted, zero-echo time (ZTE), and two ultra-short echo time sequences with 20 mu s (UTE1) and 2 ms (UTE2) echo times. CT data were manually segmented into air, soft tissue, and bone to obtain the RTP reference. Bias field corrected MR images were automatically segmented into the same tissue classes using a fuzzy c-means segmentation algorithm with multiple images as input. Similarities between segmented CT and automatic segmented MR (ASMR) images were evaluated using Dice coefficient. Three ASMR images with high similarity index were used for further RTP. Three beam arrangements were investigated. Dose distributions were compared by analysing dose volume histograms. The highest Dice coefficients were obtained for the ZTE-UTE2 combination and for the T1-UTE1-T2 combination when ZTE was unavailable. Both combinations, along with UTE1-UTE2, often used to generate ASMR images, were used for further RTP. Using 1 beam, MR based RTP underestimated the dose to be delivered to the target (range: 1.4%-7.6%). When more complex beam configurations were used, the calculated dose using the ZTE-UTE2 combination was the most accurate, with 0.7% deviation from CT, compared to 0.8% for T1-UTE1-T2 and 1.7% for UTE1-UTE2. The presented MR-only based workflow for RTP on a SARRP enables both accurate organ delineation and dose calculations using multiple MR sequences. This method can be useful in longitudinal studies where CT's cumulative radiation dose might contribute to the total dose.
引用
收藏
页数:10
相关论文
共 19 条
[1]   CT simulation for radiotherapy treatment planning [J].
Aird, EGA ;
Conway, J .
BRITISH JOURNAL OF RADIOLOGY, 2002, 75 (900) :937-949
[2]  
[Anonymous], Pattern Recognition with Fuzzy Objective Function Algorithms,, DOI 10.1007/978-1-4757-0450-1_3
[3]   The importance of tissue segmentation for dose calculations for kilovoltage radiation therapy [J].
Bazalova, Magdalena ;
Graves, Edward E. .
MEDICAL PHYSICS, 2011, 38 (06) :3039-3049
[4]  
Bolcaen J, 2014, J NEUROONC
[5]  
Cherry SR, 2004, PHYS MED BIOL, V49, pR13, DOI 10.1088/0031-9155/49/3/R01
[6]   A simulation of MRI based dose calculations on the basis of radiotherapy planning CT images [J].
Eilertsen, Karsten ;
Vestad, Line Nilsen Tor Arne ;
Geier, Oliver ;
Skretting, Arne .
ACTA ONCOLOGICA, 2008, 47 (07) :1294-1302
[7]   TLD assessment of mouse dosimetry during microCT imaging [J].
Figueroa, Said Daibes ;
Winkelmann, Christopher T. ;
Miller, William H. ;
Volkert, Wynn A. ;
Hoffman, Timothy J. .
MEDICAL PHYSICS, 2008, 35 (09) :3866-3874
[8]   Clinical target volume definition for glioblastoma radiotherapy planning: magnetic resonance imaging and computed tomography [J].
Fiorentino, A. ;
Caivano, R. ;
Pedicini, P. ;
Fusco, V. .
CLINICAL & TRANSLATIONAL ONCOLOGY, 2013, 15 (09) :754-758
[9]   Investigation of a method for generating synthetic CT models from MRI scans of the head and neck for radiation therapy [J].
Hsu, Shu-Hui ;
Cao, Yue ;
Huang, Ke ;
Feng, Mary ;
Balter, James M. .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (23) :8419-8435
[10]   Improved quality of computed tomography substitute derived from magnetic resonance (MR) data by incorporation of spatial information - potential application for MR-only radiotherapy and attenuation correction in positron emission tomography [J].
Johanson, Adam ;
Garpebring, Anders ;
Karlsson, Mikael ;
Asklund, Thomas ;
Nyholm, Tufve .
ACTA ONCOLOGICA, 2013, 52 (07) :1369-1373