Study on the Performance of a Newly Designed Cooling System Utilizing Dam Water for Internet Data Centers

被引:1
作者
Anka, Selorm Kwaku [1 ]
Boafo, Nicholas Lamptey [1 ]
Mensah, Kwesi [2 ]
Boahen, Samuel [3 ]
Lee, Kwang Ho [4 ]
Choi, Jong Min [5 ]
机构
[1] Hanbat Natl Univ, Dept Mech Engn, Grad Sch, Daejeon 34158, South Korea
[2] Lucky Core Insulating Mat Mfg, LLC, Dubai, U Arab Emirates
[3] Kwame Nkrumah Univ Sci & Technol, Dept Mech Engn, PMB, AK 039-5028, Kumasi, Ghana
[4] Korea Univ, Dept Architecture, Seoul 02841, South Korea
[5] Hanbat Natl Univ, Dept Mech Engn, Daejeon 34158, South Korea
基金
新加坡国家研究基金会;
关键词
internet data center; novel hybrid system; free cooling mode; forced cooling mode; ICOP; HEAT-PIPE; COMPRESSION REFRIGERATION; VAPOR COMPRESSION; AIR; DRIVEN; PUMP;
D O I
10.3390/en15249274
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel energy-saving hybrid cooling system that combines a forced-cooling cycle and a free-cooling cycle was developed to increase the energy efficiency of cooling systems in year-round operation of an internet data center with high heat loads. This system effectively utilizes a dam deep water source to reduce energy consumption in internet data centers. The hybrid cooling system operates in forced-cooling mode when the entering water temperature exceeds the mode change temperature of 9 degrees C, but switches to free-cooling mode when the ambient temperature falls below the mode change temperature. In this paper, the cooling performance of the hybrid system was assessed under various operating conditions based on entering water temperature fluctuation. Because the cooling effectiveness of this type of system is highly dependent on the outside climate, its usefulness and suitability for different periods and zones must be investigated. The annual energy saving performance of the new system was estimated and compared to a conventional cooling system in terms of the integrated coefficient of performance, based on the hourly weather air temperature and water temperature bin data collected from 16 cities of different climate zones in South Korea. The experimental findings revealed that the novel hybrid internet data center cooling system showed a 67% annual operating performance over a conventional air source internet data center cooling system due to the adoption of a dam deep water source.
引用
收藏
页数:19
相关论文
共 23 条
[1]   Review on Cooling System Energy Consumption in Internet Data Centers [J].
Amoabeng, Kofi Owura ;
Choi, Jong Min .
INTERNATIONAL JOURNAL OF AIR-CONDITIONING AND REFRIGERATION, 2016, 24 (04)
[2]   Performance optimization of an air source HVAC system for an internet data center building using the integrated COP method [J].
Anka, Selorm Kwaku ;
Mensah, Kwesi ;
Boahen, Samuel ;
Ohm, Tae In ;
Cho, Yong ;
Choi, Jong Woong ;
Choo, Sung Hoon ;
Kim, Han-Young ;
Choi, Jong Min .
JOURNAL OF BUILDING ENGINEERING, 2022, 61
[3]  
[Anonymous], 1999, 21099 ANSIAMCA
[4]  
[Anonymous], 2020, 127 ANSIASHRAE
[5]  
[Anonymous], 1998, 132562 ISO
[6]  
[Anonymous], 2017, AHRI Standard 1361 (SI)
[7]   Potentiometric and economic analysis of using air and water-side economizers for data center cooling based on various weather conditions [J].
Deymi-Dashtebayaz, Mahdi ;
Namanlo, Sajad Valipour .
INTERNATIONAL JOURNAL OF REFRIGERATION, 2019, 99 :213-225
[8]   Simultaneous use of air-side and water-side economizers with the air source heat pump in a data center for cooling and heating production [J].
Deymi-Dashtebayaz, Mandi ;
Namanlo, Sajjad Valipour ;
Arabkoohsar, Ahmad .
APPLIED THERMAL ENGINEERING, 2019, 161
[9]  
Gao T., 2013, COMP THERMAL ENERGY
[10]  
Gao T., 2015, Comparative Analysis of Different