Effect of respiratory phases on MR lung signal intensity and lung conspicuity using segmented multiple inversion recovery turbo spin echo (MIR-TSE)

被引:0
作者
Mai, VM
Chen, Q
Li, W
Hatabu, H
Edelman, RR
机构
[1] Beth Israel Deaconess Med Ctr, Dept Radiol, Boston, MA 02215 USA
[2] Harvard Univ, Sch Med, Boston, MA USA
关键词
lung; pulmonary parenchyma; MRI; multiple inversion recovery (MIR); segmented turbo spin echo;
D O I
10.1002/(SICI)1522-2594(200005)43:5<760::AID-MRM20>3.3.CO;2-D
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of this study was to determine the effect of respiratory phase on signal intensity of the lung. Lung images were obtained from eleven healthy human volunteers using a multiple inversion recovery segmented turbo spin echo sequence (MIR-TSE). MIR exploits the difference in T-1 between different tissues to effectively null signal contributions from fat and muscle for improved visualization of the lung. The volunteers were asked to perform breath-holding on end inspiration or end expiration. There was a significant decrease in signal intensity of the lung with average SNR of 7.3 +/- 0.9 vs. 14.4 +/- 0.8 for coronal slices, and 9.5 +/- 1.5 vs. 16.0 +/- 2.4 for sagittal breath-hold images acquired during end inspiration compared with end expiration. It is concluded that MRI of the lungs should be performed during end expiration in order to optimize image quality. Magn Reson Med 43: 760-763, 2000. (C) 2000 Wiley-Liss, Inc.
引用
收藏
页码:760 / 763
页数:4
相关论文
共 14 条
[1]  
Albertin K, 1996, APPL MAGNETIC RESONA, P73
[2]   MULTISLICE, BREATHHOLD IMAGING OF THE LUNG WITH SUBMILLISECOND ECHO TIMES [J].
ALSOP, DC ;
HATABU, H ;
BONNET, M ;
LISTERUD, J ;
GEFTER, W .
MAGNETIC RESONANCE IN MEDICINE, 1995, 33 (05) :678-682
[3]   LUNG PARENCHYMA - PROJECTION RECONSTRUCTION MR-IMAGING [J].
BERGIN, CJ ;
PAULY, JM ;
MACOVSKI, A .
RADIOLOGY, 1991, 179 (03) :777-781
[4]   A MATHEMATICAL-MODEL OF DIAMAGNETIC LINE BROADENING IN LUNG-TISSUE AND SIMILAR HETEROGENEOUS SYSTEMS - CALCULATIONS AND MEASUREMENTS [J].
CASE, TA ;
DURNEY, CH ;
AILION, DC ;
CUTILLO, AG ;
MORRIS, AH .
JOURNAL OF MAGNETIC RESONANCE, 1987, 73 (02) :304-314
[5]   THE LOSS OF SMALL OBJECTS IN VARIABLE TE IMAGING - IMPLICATIONS FOR FSE, RARE, AND EPI [J].
CONSTABLE, RT ;
GORE, JC .
MAGNETIC RESONANCE IN MEDICINE, 1992, 28 (01) :9-24
[6]   MULTIPLE INVERSION RECOVERY REDUCES STATIC TISSUE SIGNAL IN ANGIOGRAMS [J].
DIXON, WT ;
SARDASHTI, M ;
CASTILLO, M ;
STOMP, GP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 18 (02) :257-268
[7]   CALCULATION AND INTERPRETATION OF INHOMOGENEOUS LINE BROADENING IN MODELS OF LUNGS AND OTHER HETEROGENEOUS STRUCTURES [J].
DURNEY, CH ;
BERTOLINA, J ;
AILION, DC ;
CHRISTMAN, R ;
CUTILLO, AG ;
MORRIS, AH ;
HASHEMI, S .
JOURNAL OF MAGNETIC RESONANCE, 1989, 85 (03) :554-570
[8]  
GEFTER WB, 1996, APPL MAGNETIC RESONA, P503
[9]  
GREEN JF, 1982, FUNDAMENTAL CARDIOVA
[10]  
Mai VM, 1999, MAGNET RESON MED, V41, P866, DOI 10.1002/(SICI)1522-2594(199905)41:5<866::AID-MRM2>3.0.CO