Determination of Mn(II) ion by a modified carbon paste electrode based on multi-walled carbon nanotubes (MWCNTs) in different water samples

被引:41
作者
Ali, Tamer Awad [1 ]
Mohamed, Gehad G. [2 ]
机构
[1] EPRI, Cairo 11727, Egypt
[2] Cairo Univ, Fac Sci, Dept Chem, Giza 12613, Egypt
关键词
Multi-walled carbon nanotubes; Manganese; Water samples; Carbon paste sensors; SCREEN-PRINTED ELECTRODE; MEMBRANE-ELECTRODE; POTENTIOMETRIC DETERMINATION; SELECTIVE ELECTRODES; MANGANESE; CONSTRUCTION; COPPER(II); TITRATION; GRAPHITE; TOXICITY;
D O I
10.1016/j.snb.2014.05.137
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
For the first time a novel derivatized multi-walled carbon nanotubes-based on Mn(II) carbon paste electrodes is reported. At optimum values of variable conditions, the proposed electrodes responded toward Mn(II) ion linearly in the range of 7.8 x 10(-7)-1.0 x 10(-1) and 2.7 x 10(-8)-1.0 x 10(-1) mol L-1 with slope of 27.72 +/- 0.8 and 30.04 +/- 0.5 mV decade(-1) of Mn(II) ion concentration and detection limit of 7.8 x 10(-7) and 2.7 x 10(-8) mol L-1 for KTpC1PB-CPE (electrode (IV)) and KTpC1PB/MWCNT5-CPE (electrode (VIII)), respectively. The electrodes response is independent of pH in the range of 4-8 and 3-9, with a fast response time (8 and 5 s) at 25 degrees C for electrode (IV) and electrode (VIII), respectively. Moreover, the electrodes also showed high selectivity and long life time (more than 3 and 4 months) for electrode (IV) and electrode (VIII), respectively. The electrodes showed good selectivity for Mn(II) ion toward wide variety of metal ions. The proposed sensors were successfully applied for the determination of Mn(II) ion in different real and environmental samples and as indicator electrodes. The results obtained compared well with those obtained using atomic absorption spectrometry. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:699 / 707
页数:9
相关论文
共 45 条
[1]   Manganese(II) Ion-Selective Membrane Electrode Based on N-(2-picolinamido ethyl)-Picolinamide as Neutral Carrier [J].
Aghaie, M. ;
Giahi, M. ;
Zawari, M. .
BULLETIN OF THE KOREAN CHEMICAL SOCIETY, 2010, 31 (10) :2980-2984
[2]   A New Screen-printed Ion Selective Electrode for Determination of Citalopram Hydrobromide in Pharmaceutical Formulation [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. ;
Al-Sabagh, A. M. ;
Migahed, M. A. .
CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2014, 42 (04) :565-572
[3]  
Ali TA, 2014, INT J ELECTROCHEM SC, V9, P2420
[4]  
Ali TA, 2014, INT J ELECTROCHEM SC, V9, P1812
[5]   Thiol surfactant assembled on gold nanoparticles ion exchanger for screen-printed electrode fabrication. Potentiometric determination of Ce(III) in environmental polluted samples [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. ;
Azzam, E. M. S. ;
Abd-elaal, Ali A. .
SENSORS AND ACTUATORS B-CHEMICAL, 2014, 191 :192-203
[6]   Modified Screen-Printed Electrode for Potentiometric Determination of Copper(II) in Water Samples [J].
Ali, Tamer Awad ;
Mohamed, Gehad G. ;
El-Dessouky, Maher M. I. ;
Abou El-Ella, Salwa M. ;
Mohamed, Rabab T. F. .
JOURNAL OF SOLUTION CHEMISTRY, 2013, 42 (06) :1336-1354
[7]  
Ali TA, 2013, INT J ELECTROCHEM SC, V8, P1469
[8]  
Awadallah AE etal, 2013, EGYPT J PETROLEUM, V22, P27, DOI [DOI 10.1016/j.ejpe.2012.11.012, 10.1016/j.ejpe.2012.11.012, DOI 10.1016/J.EJPE.2012.11.012]
[9]  
Cai Z.C., 2013, YEJIN FENXI, V33, P45
[10]  
Daifullah A. A. M., 2003, African Journal of Environmental Assessment and Management, V6, P16