Development of Large Bismuth Absorbers for Magnetic Calorimeters Applied to Hard X-ray Spectrometry

被引:1
作者
Rodrigues, M. [1 ]
Loidl, M. [1 ]
Pies, C. [2 ]
Fleischmann, A. [2 ]
Enss, C. [2 ]
机构
[1] CEA, LIST, Lab Natl Henri Becquerel, F-91191 Gif Sur Yvette, France
[2] Heidelberg Univ, KIP, D-69120 Heidelberg, Germany
关键词
Bismuth absorber; Magnetic calorimeter; X-ray spectrometry; MICROCALORIMETERS; PERFORMANCE; ARRAYS;
D O I
10.1007/s10909-014-1124-6
中图分类号
O59 [应用物理学];
学科分类号
摘要
Bismuth is an interesting material for magnetic calorimeter absorbers applied to high energy resolution X-ray spectrometry; it has a low specific heat and high atomic number. However, past detector developments with Bi absorbers were confronted with the low thermal conductivity of bismuth that degraded the energy resolution and deformed the detector response function (non-Gaussian energy peak). In the present study, we have investigated the performances of large bulk bismuth absorbers ( mm) thermally coupled to metallic magnetic sensors. Despite a very good baseline energy resolution, detectors with monolithic bismuth absorbers have degraded FWHM energy resolutions with any type of thermal coupling between the absorber and the sensor tested. In comparison tests with BiCu and BiAg bilayer absorbers demonstrated much better performances.
引用
收藏
页码:610 / 616
页数:7
相关论文
共 11 条
  • [1] Performance of TES X-ray microcalorimeters with a novel absorber design
    Bandler, S. R.
    Brekosky, R. P.
    Brown, A. -D.
    Chervenak, J. A.
    Figueroa-Feliciano, E.
    Finkbeiner, F. M.
    Iyomoto, N.
    Kelley, R. L.
    Kilbourne, C. A.
    Porter, F. S.
    Sadleir, J.
    Smith, S. J.
    [J]. JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) : 400 - 405
  • [2] SPECIFIC HEAT OF ANTIMONY AND BISMUTH BETWEEN 0.03 AND 0.8K
    COLLAN, HK
    KRUSIUS, M
    PICKETT, GR
    [J]. PHYSICAL REVIEW B, 1970, 1 (07): : 2888 - &
  • [3] Fleischmann A, 2005, TOP APPL PHYS, V99, P151
  • [4] Thermal physics of transition edge sensor arrays
    Hoevers, HFC
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 559 (02) : 702 - 705
  • [5] LOW-TEMPERATURE RESISTIVITY AND THERMOELECTRIC RATIO OF COPPER AND GOLD
    KHOSHENEVISAN, M
    PRATT, WP
    SCHROEDER, PA
    STEENWYK, SD
    [J]. PHYSICAL REVIEW B, 1979, 19 (08) : 3873 - 3878
  • [6] THERMAL-CONDUCTIVITY OF BISMUTH AT ULTRALOW TEMPERATURES
    PRATT, WP
    UHER, C
    [J]. PHYSICS LETTERS A, 1978, 68 (01) : 74 - 76
  • [7] A Novel Type of Absorber Presenting a Constant Detection Efficiency for up to 25 keV X-Ray Photons
    Rodrigues, M.
    Loidl, M.
    Le-Bret, C.
    [J]. JOURNAL OF LOW TEMPERATURE PHYSICS, 2012, 167 (3-4) : 510 - 515
  • [8] Metallic magnetic calorimeters for γ-ray spectrometry
    Rodrigues, M.
    Pabinger, A.
    Lausberg, S.
    Loidl, M.
    Censier, B.
    Bouchard, J.
    Fleischmann, L.
    Fleischmann, A.
    Enss, C.
    [J]. LOW TEMPERATURE DETECTORS LTD 13, 2009, 1185 : 583 - +
  • [9] Performance of micro-fabricated magnetic calorimeters arrays for X-ray spectroscopy
    Rotzinger, H.
    Adams, J.
    Bandler, S. R.
    Beyer, J.
    Eguchi, H.
    Figueroa-Feliciano, E.
    Hsieh, W.
    Seidel, G. M.
    Stevenson, T.
    [J]. JOURNAL OF LOW TEMPERATURE PHYSICS, 2008, 151 (1-2) : 351 - 356
  • [10] Determining the thermal diffusivity in microcalorimeter absorbers and its effect on detector response
    Saab, T.
    Figueroa-Feliciano, E.
    Iyomoto, N.
    Bandler, S. R.
    Chervenak, J. A.
    Kelley, R. L.
    Kilbourne, C. A.
    Porter, F. S.
    Sadleir, J. E.
    [J]. JOURNAL OF APPLIED PHYSICS, 2007, 102 (10)