Quantification of serum C-peptide by isotope-dilution liquid chromatography-tandem mass spectrometry: Enhanced detection using chemical modification and immunoaffinity purification

被引:20
|
作者
Kinumi, Tomoya [1 ]
Mizuno, Ryoko [1 ]
Takatsu, Akiko [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, NMIJ, Biomed Stand Sect, Tsukuba, Ibaraki 3058563, Japan
基金
日本学术振兴会;
关键词
C-peptide; Isotope-dilution mass spectrometry; LC-MS/MS; Chemical modification; Immunoaffinity purification; INSULIN-SECRETION; QUANTITATION;
D O I
10.1016/j.jchromb.2014.02.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was developed to quantify human serum C-peptide by isotope-dilution mass spectrometry (ID MS). This new approach used immunoaffinity purification and chemical modification to improve the sensitivity which covered the wide range of reference interval of serum C-peptide. The immunoaffinity purification was performed using monoclonal antibody against human C-peptide that was immobilized on magnetic beads, and the purified C-peptide was chemically modified using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) prior to liquid chromatography-tandem mass spectrometry (LC-MS/MS). With this method, the LC-MS/MS peak area increased 23-fold compared with the conventional purification by solid-phase extraction and without chemical modification. The limit of quantification was estimated to be 0.003 ng on column, which was lower than previously reported. The validation study showed that (1) the response in the 0.003-2.9 ng range on column was linear (regression coefficient, r(2) =0.9994), (2) the relative standard deviation (RSD) within and between days was inferior to 4.0%, and (3) the spike and recovery test showed the mean recoveries ranging between 99% and 108%. Comparison with an established commercial immunoassay showed high correlation (r(2) =0.9994) at serum concentration of 0.19-8.49 ng/mL. These assessments suggest that this ID MS-based approach can quantify human serum C-peptide with high sensitivity and precision in the reference interval and find a potential use in the reference measurement procedure of serum C-peptide, allowing traceable measurement. This method may also generally be applied to peptide quantification in biological fluids with high sensitivity. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 50 条
  • [31] Quantification of Glycosaminoglycans in Urine by Isotope-Dilution Liquid Chromatography-Electrospray Ionization Tandem Mass Spectrometry
    Zhang, Haoyue
    Young, Sarah P.
    Millington, David S.
    CURRENT PROTOCOLS, 2023, 3 (03):
  • [32] An Accurate Isotope Dilution Liquid Chromatography- Tandem Mass Spectrometry Method for Serum C-Peptide and Its Use in Harmonization in China
    Deng, Yuhang
    Zhang, Chao
    Wang, Jing
    Zeng, Jie
    Zhang, Jiangtao
    Zhang, Tianjiao
    Zhao, Haijian
    Zhou, Weiyan
    Zhang, Chuanbao
    ANNALS OF LABORATORY MEDICINE, 2023, 43 (04) : 345 - 354
  • [33] Determination of cyclophosphamide and ifosfamide in sewage effluent by stable isotope-dilution liquid chromatography-tandem mass spectrometry
    Llewellyn, N.
    Lloyd, P.
    Juergens, M. D.
    Johnson, A. C.
    JOURNAL OF CHROMATOGRAPHY A, 2011, 1218 (47) : 8519 - 8528
  • [34] Application of a C-peptide electrospray ionization-isotope dilution-liquid chromatography-tandem mass spectrometry measurement procedure for the evaluation of five C-peptide immunoassays for urine
    Fierens, C
    Stöckl, D
    Baetens, D
    De Leenheer, AP
    Thienpont, LM
    JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 792 (02): : 249 - 259
  • [35] Detection of functional ricin by immunoaffinity and liquid chromatography-tandem mass spectrometry
    Becher, F.
    Duriez, E.
    Volland, H.
    Tabet, J. C.
    Ezan, E.
    ANALYTICAL CHEMISTRY, 2007, 79 (02) : 659 - 665
  • [36] Quantification of 11 thyroid hormones and associated metabolites in blood using isotope-dilution liquid chromatography tandem mass spectrometry
    Martin Hansen
    Xuan Luong
    David L. Sedlak
    Caren C. Helbing
    Tyrone Hayes
    Analytical and Bioanalytical Chemistry, 2016, 408 : 5429 - 5442
  • [37] Quantification of free serum cortisol based on equilibrium dialysis and isotope dilution-liquid chromatography-tandem mass spectrometry
    Kirchhoff, Fabian
    Briegel, Josef
    Vogeser, Michael
    CLINICAL BIOCHEMISTRY, 2011, 44 (10-11) : 894 - 899
  • [38] A simple and reliable measurement procedure for determination of glycocholic acid in human serum by isotope-dilution liquid chromatography-tandem mass spectrometry
    Wang, Ahui
    Xu, Yuzhu
    Ou, Yangfen
    Han, Liqiao
    Zhang, Qiaoxuan
    Zhan, Min
    Liu, Hongcan
    Ke, Peifeng
    Yan, Jun
    Huang, Xianzhang
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2021, 464
  • [39] Accumulation of intact sulfur mustard in adipose tissue and toxicokinetics by chemical conversion and isotope-dilution liquid chromatography-tandem mass spectrometry
    Xu, Bin
    Zong, Cheng
    Zhang, Yajiao
    Zhang, Tianhong
    Wang, Xiaoying
    Qi, Meiling
    Wu, Jianfeng
    Guo, Lei
    Wang, Peng
    Chen, Jia
    Liu, Qin
    Xu, Hua
    Xie, Jianwei
    Zhang, Zhenqing
    ARCHIVES OF TOXICOLOGY, 2017, 91 (02) : 735 - 747
  • [40] Quantification of 11 thyroid hormones and associated metabolites in blood using isotope-dilution liquid chromatography tandem mass spectrometry
    Hansen, Martin
    Luong, Xuan
    Sedlak, David L.
    Helbing, Caren C.
    Hayes, Tyrone
    ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2016, 408 (20) : 5429 - 5442