Quantification of serum C-peptide by isotope-dilution liquid chromatography-tandem mass spectrometry: Enhanced detection using chemical modification and immunoaffinity purification

被引:20
作者
Kinumi, Tomoya [1 ]
Mizuno, Ryoko [1 ]
Takatsu, Akiko [1 ]
机构
[1] Natl Inst Adv Ind Sci & Technol, NMIJ, Biomed Stand Sect, Tsukuba, Ibaraki 3058563, Japan
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2014年 / 953卷
基金
日本学术振兴会;
关键词
C-peptide; Isotope-dilution mass spectrometry; LC-MS/MS; Chemical modification; Immunoaffinity purification; INSULIN-SECRETION; QUANTITATION;
D O I
10.1016/j.jchromb.2014.02.019
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A method was developed to quantify human serum C-peptide by isotope-dilution mass spectrometry (ID MS). This new approach used immunoaffinity purification and chemical modification to improve the sensitivity which covered the wide range of reference interval of serum C-peptide. The immunoaffinity purification was performed using monoclonal antibody against human C-peptide that was immobilized on magnetic beads, and the purified C-peptide was chemically modified using 6-aminoquinolyl-N-hydroxysuccinimidyl carbamate (AQC) prior to liquid chromatography-tandem mass spectrometry (LC-MS/MS). With this method, the LC-MS/MS peak area increased 23-fold compared with the conventional purification by solid-phase extraction and without chemical modification. The limit of quantification was estimated to be 0.003 ng on column, which was lower than previously reported. The validation study showed that (1) the response in the 0.003-2.9 ng range on column was linear (regression coefficient, r(2) =0.9994), (2) the relative standard deviation (RSD) within and between days was inferior to 4.0%, and (3) the spike and recovery test showed the mean recoveries ranging between 99% and 108%. Comparison with an established commercial immunoassay showed high correlation (r(2) =0.9994) at serum concentration of 0.19-8.49 ng/mL. These assessments suggest that this ID MS-based approach can quantify human serum C-peptide with high sensitivity and precision in the reference interval and find a potential use in the reference measurement procedure of serum C-peptide, allowing traceable measurement. This method may also generally be applied to peptide quantification in biological fluids with high sensitivity. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:138 / 142
页数:5
相关论文
共 22 条
  • [1] Sensitive and Rapid Method for Amino Acid Quantitation in Malaria Biological Samples Using AccQ.Tag Ultra Performance Liquid Chromatography-Electrospray Ionization-MS/MS with Multiple Reaction Monitoring
    Armenta, Jenny M.
    Cortes, Diego F.
    Pisciotta, John M.
    Shuman, Joel L.
    Blakeslee, Kenneth
    Rasoloson, Dominique
    Ogunbiyi, Oluwatosin
    Sullivan, David J., Jr.
    Shulaev, Vladimir
    [J]. ANALYTICAL CHEMISTRY, 2010, 82 (02) : 548 - 558
  • [2] SYNTHESIS OF A FLUORESCENT DERIVATIZING REAGENT, 6-AMINOQUINOLYL-N-HYDROXYSUCCINIMIDYL CARBAMATE, AND ITS APPLICATION FOR THE ANALYSIS OF HYDROLYSATE AMINO-ACIDS VIA HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    COHEN, SA
    MICHAUD, DP
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 211 (02) : 279 - 287
  • [3] QUANTITATION OF HUMAN PANCREATIC BETA-CELL FUNCTION BY IMMUNOASSAY OF C-PEPTIDE IN URINE
    HORWITZ, DL
    RUBENSTEIN, AH
    KATZ, AI
    [J]. DIABETES, 1977, 26 (01) : 30 - 35
  • [4] ELECTROSPRAY ANALYSIS OF PROTEINS - A COMPARISON OF POSITIVE-ION AND NEGATIVE-ION MASS-SPECTRA AT HIGH AND LOW PH
    KELLY, MA
    VESTLING, MM
    FENSELAU, CC
    SMITH, PB
    [J]. ORGANIC MASS SPECTROMETRY, 1992, 27 (10): : 1143 - 1147
  • [5] Development of SI-traceable C-peptide certified reference material NMIJ CRM 6901-a using isotope-dilution mass spectrometry-based amino acid analyses
    Kinumi, Tomoya
    Goto, Mari
    Eyama, Sakae
    Kato, Megumi
    Kasama, Takeshi
    Takatsu, Akiko
    [J]. ANALYTICAL AND BIOANALYTICAL CHEMISTRY, 2012, 404 (01) : 13 - 21
  • [6] Development of an isotope dilution assay for precise determination of insulin, C-peptide, and proinsulin levels in non-diabetic and type II diabetic individuals with comparison to immunoassay
    Kippen, AD
    Cerini, F
    Vadas, L
    Stocklin, R
    Vu, L
    Offord, RE
    Rose, K
    [J]. JOURNAL OF BIOLOGICAL CHEMISTRY, 1997, 272 (19) : 12513 - 12522
  • [7] C-peptide - Much more than a byproduct of insulin biosynthesis
    Marques, RG
    Fontaine, MJ
    Rogers, J
    [J]. PANCREAS, 2004, 29 (03) : 231 - 238
  • [8] C-peptide microheterogeneity in type 2 diabetes populations
    Oran, Paul E.
    Jarvis, Jason W.
    Borges, Chad R.
    Nelson, Randall W.
    [J]. PROTEOMICS CLINICAL APPLICATIONS, 2010, 4 (01) : 106 - 111
  • [9] USE OF BIOSYNTHETIC HUMAN C-PEPTIDE IN THE MEASUREMENT OF INSULIN-SECRETION RATES IN NORMAL VOLUNTEERS AND TYPE-I DIABETIC-PATIENTS
    POLONSKY, KS
    LICINIOPAIXAO, J
    GIVEN, BD
    PUGH, W
    RUE, P
    GALLOWAY, J
    KARRISON, T
    FRANK, B
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1986, 77 (01) : 98 - 105
  • [10] QUANTITATIVE STUDY OF INSULIN-SECRETION AND CLEARANCE IN NORMAL AND OBESE SUBJECTS
    POLONSKY, KS
    GIVEN, BD
    HIRSCH, L
    SHAPIRO, ET
    TILLIL, H
    BEEBE, C
    GALLOWAY, JA
    FRANK, BH
    KARRISON, T
    VANCAUTER, E
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1988, 81 (02) : 435 - 441