Optimization of a fully 3D single scatter simulation algorithm for 3D PET

被引:100
作者
Accorsi, R
Adam, LE
Werner, ME
Karp, JS
机构
[1] Childrens Hosp Philadelphia, Dept Radiol, Div Nucl Med, Philadelphia, PA 19104 USA
[2] Univ Penn, Sch Med, Dept Radiol, Philadelphia, PA 19104 USA
[3] Philips Med Syst, Philadelphia, PA 19104 USA
关键词
D O I
10.1088/0031-9155/49/12/008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We describe a new implementation of a single scatter simulation (SSS) algorithm for the prediction and correction of scatter in 3D PET. In this implementation, out of field of view (FoV) scatter and activity, side shields and oblique tilts are explicitly modelled. Comparison of SSS predictions with Monte Carlo simulations and experimental data from uniform, line and cold-bar phantoms showed that the code is accurate for uniform as well as asymmetric objects and can model different energy resolution crystals and low level discriminator (LLD) settings. Absolute quantitation studies show that for most applications, the code provides a better scatter estimate than the tail-fitting scatter correction method currently in use at our institution. Several parameters such as the density of scatter points, the number of scatter distribution sampling points and the axial extent of the FoV were optimized to minimize execution time, with particular emphasis on patient studies. Development and optimization were carried out in the case of GSO-based scanners, which enjoy relatively good energy resolution. SSS estimates for scanners with lower energy resolution may result in different agreement, especially because of a higher fraction of multiple scatter events. The algorithm was applied to a brain phantom as well as to clinical whole-body studies. It proved robust in the case of large patients, where the scatter fraction increases. The execution time, inclusive of interpolation, is typically under 5 min for a whole-body study (axial FoV: 81 cm) of a 100 kg patient.
引用
收藏
页码:2577 / 2598
页数:22
相关论文
共 50 条
[21]   An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner [J].
Gao Fei ;
Ryoko, Yamada ;
Mitsuo, Watanabe ;
Liu Hua-Feng .
CHINESE PHYSICS B, 2009, 18 (07) :3066-3072
[22]   Investigation of accelerated Monte Carlo techniques for PET simulation and 3D PET scatter correction [J].
Holdsworth, CH ;
Levin, CS ;
Farquhar, TH ;
Dahlbom, M ;
Hoffman, EJ .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) :74-81
[23]   Evaluation of a fully 3D, big bore TOF PET scanner with reduced scatter shields [J].
Scheuermann, Joshua S. ;
Surti, Suleman ;
Kolthammer, Jeffrey A. ;
Karp, Joel S. .
2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, :3589-+
[24]   Fully 3D iterative scatter-corrected OSEM for HRRT PET using a GPU [J].
Kim, Kyung Sang ;
Ye, Jong Chul .
PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (15) :4991-5009
[25]   Performance of a fast maximum likelihood algorithm for fully 3D pet reconstruction [J].
Matej, S ;
Browne, JA .
THREE-DIMENSIONAL IMAGE RECONSTRUCTION IN RADIOLOGY AND NUCLEAR MEDICINE, 1996, 4 :297-315
[26]   Maximum likelihood reconstruction in fully 3D PET via the SAGE algorithm [J].
Ollinger, JM ;
Goggin, AS .
1996 IEEE NUCLEAR SCIENCE SYMPOSIUM - CONFERENCE RECORD, VOLS 1-3, 1997, :1594-1598
[27]   Evaluation of simulation-based scatter correction for 3D PET cardiac imaging [J].
Watson, CC ;
Newport, D ;
Casey, ME ;
deKemp, RA ;
Beanlands, RS ;
Schmand, M .
1995 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD, VOLS 1-3, 1996, :1373-1377
[28]   A Comparative Study of Multiple Scatter Estimations in 3D PET [J].
Qian, Hua ;
Manjeshwar, Ravi ;
Thielemans, Kris .
2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, :2700-2702
[29]   Efficient Bregman Iteration in fully 3D PET [J].
Szirmay-Kalos, Laszlo ;
Toth, Balazs ;
Jakab, Gabor .
2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,
[30]   AN INVESTIGATION OF PRACTICAL SCATTER CORRECTION TECHNIQUES FOR 3D PET [J].
TOWNSEND, DW ;
CHOI, Y ;
SASHIN, D ;
MINTUN, MA ;
GROOTOONK, S ;
BAILEY, DL .
JOURNAL OF NUCLEAR MEDICINE, 1994, 35 (05) :P50-P50