Measurement of neutrons down to 200 keV with pulse shape discrimination using an EJ-301 liquid scintillator

被引:2
|
作者
Lewis, A. M. [1 ]
Blain, E. [1 ]
Daskalakis, A. M. [1 ]
Danon, Y. [1 ]
机构
[1] Rensselaer Polytech Inst, Gaerttner LINAC Ctr, Troy, NY 12180 USA
来源
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT | 2018年 / 899卷
关键词
Neutrons; PSD; SCATTERING;
D O I
10.1016/j.nima.2018.05.024
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Pulse shape discrimination is a method commonly used to separate gamma and neutron signals in liquid scintillation detectors. The method works well for neutrons above 500 keV, but as the energy deposited in the detector decreases, so does the effectiveness. In order to utilize pulse shape discrimination capabilities at lower energies, a 1.27 cm thick EJ-301 detector operated at a bias voltage of 2200 V has been used. The detector has been shown to have an average misclassification of 0.5% of gamma pulses over the total energy range from 35 keVee to 400 keVee, and 2.0% in the most sensitive region from 35 keVee to 45 keVee. A measurement performed using the time-of-flight method at the Gaerttner Linear Accelerator Facility at Rensselaer Polytechnic Institute has shown that with the pulse shape discrimination method, this detector can detect and characterize neutron pulses down to 200 keV.
引用
收藏
页码:80 / 84
页数:5
相关论文
共 50 条
  • [1] Improved pulse shape discrimination in EJ-301 liquid scintillators
    Lang, R. F.
    Masson, D.
    Pienaar, J.
    Roettger, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 856 : 26 - 31
  • [2] Digital pulse shape discrimination technique for liquid scintillation detector EJ-301
    Bo, W.
    Gang, L.
    Kun, L.
    Zhi, C.
    Yu, H.
    Hu, Z.
    Cheng, Y.
    Daibo, Y.
    Shaoli, Z.
    JOURNAL OF INSTRUMENTATION, 2019, 14 (11)
  • [3] A Composite Method for Improving the Pulse Shape Discrimination Efficiency of a Scintillation Detector Using EJ-301 Liquid
    Phan Van Chuan
    Nguyen Xuan Hai
    Nguyen Ngoc Anh
    Pham Dinh Khang
    Nguyen Quang Hung
    Truong Van Minh
    Nguyen Duy Ly
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
  • [4] Digital pulse shape discrimination methods for n-γ separation in an EJ-301 liquid scintillation detector
    万波
    张雪荧
    陈亮
    葛红林
    马飞
    张宏斌
    鞠永芹
    张艳斌
    李严严
    许晓伟
    Chinese Physics C, 2015, 39 (11) : 82 - 86
  • [5] Digital pulse shape discrimination methods for n-γ separation in an EJ-301 liquid scintillation detector
    Wan Bo
    Zhang Xue-Ying
    Chen Liang
    Ge Hong-Lin
    Ma Fei
    Zhang Hong-Bin
    Ju Yong-Qin
    Zhang Yan-Bin
    Li Yan-Yan
    Xu Xiao-Wei
    CHINESE PHYSICS C, 2015, 39 (11)
  • [6] Digital pulse shape discrimination methods for n-γ separation in an EJ-301 liquid scintillation detector
    万波
    张雪荧
    陈亮
    葛红林
    马飞
    张宏斌
    鞠永芹
    张艳斌
    李严严
    许晓伟
    Chinese Physics C, 2015, (11) : 82 - 86
  • [7] Evaluating four neutron-gamma discrimination methods with EJ-301 scintillator
    Van Chuan Phan
    Xuan Hai Nguyen
    Analog Integrated Circuits and Signal Processing, 2019, 98 : 75 - 84
  • [8] Evaluating four neutron-gamma discrimination methods with EJ-301 scintillator
    Phan Van Chuan
    Nguyen Xuan Hai
    ANALOG INTEGRATED CIRCUITS AND SIGNAL PROCESSING, 2019, 98 (01) : 75 - 84
  • [9] Neutron-gamma pulse shape discrimination for EJ301 liquid scintillator based on machine learning
    Jiahao Xu
    Wei Cheng
    Wenbao Jia
    Qingbo Chen
    Ronghua Zhang
    Yan Zhang
    Can Cheng
    Journal of Radioanalytical and Nuclear Chemistry, 2024, 333 : 905 - 916
  • [10] Neutron-gamma pulse shape discrimination for EJ301 liquid scintillator based on machine learning
    Xu, Jiahao
    Cheng, Wei
    Jia, Wenbao
    Chen, Qingbo
    Zhang, Ronghua
    Zhang, Yan
    Cheng, Can
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2024, 333 (02) : 905 - 916