A highly sensitive competitive enzyme immunoassay of broad specificity quantifying microcystins and nodularins in water samples

被引:38
作者
Khreich, Nathalie [1 ]
Lamourette, Patricia [1 ]
Renard, Pierre-Yves [2 ]
Clave, Guillaume [3 ]
Fenaille, Francois [1 ]
Creminon, Christophe [1 ]
Volland, Herve [1 ]
机构
[1] CEA, iBiTecS, Serv Pharmacol & Immunoanal, F-91191 Gif Sur Yvette, France
[2] Univ Rouen, IRCOF, F-76130 Mont St Aignan, France
[3] CNRS, COBRA, UMR 6014, F-76130 Mont St Aignan, France
关键词
Microcystins; Nodularins; Monoclonal antibody; Enzyme Immunoassay; HPLC; LC-MS/MS; MONOCLONAL-ANTIBODIES; PROTEIN PHOSPHATASE; LIQUID-CHROMATOGRAPHY; CYANOBACTERIAL HEPATOTOXINS; MASS-SPECTROMETRY; INHIBITION ASSAY; LR; ACETYLCHOLINESTERASE; PURIFICATION; EXTRACTION;
D O I
10.1016/j.toxicon.2008.12.021
中图分类号
R9 [药学];
学科分类号
1007 ;
摘要
Microcystins (Mcs) form a group of cyclic heptapeptides produced by common cyanobacteria (blue green algae) and cause both acute and chronic toxicity. For immunization purposes, an amino derivative of MC-LR was prepared before coupling to BSA. Among the different monoclonal antibodies produced, mAb MC159 was selected due to its broad specificity to develop a sensitive enzyme immunoassay (EIA). This method measures MC-LR, MC-YR, MC-LA, nodularins in a similar way and exhibits an important recognition (cross reactivity up to 69%) for Adda analogues. Using MC-LR as standard, the present EIA proved to be very sensitive with a limit of detection close to 10 fmol/ml, largely below the provisional guideline level for drinking water proposed by the WHO (1 pmol/ml for MC-LR). This assay showed a high accuracy (CV% < 12) and a high recovery rate for MC-LR in spiked surface water (up to 96.5%). Moreover due to its broad spectrum of recognition, this method allows a real quantification of the sum of MCs in water bloom and cyanobacteria culture samples. Indeed, in parallel analysis of these samples using HPLC, EIA shows a good relationship between both measurements while LC-MS/MS demonstrates the presence of different variants of MCs whose heterogeneity did not impair EIA measurement. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:551 / 559
页数:9
相关论文
共 38 条
[1]   Assessment of protein phosphatase in a re-usable rapid assay format in detecting microcystins and okadaic acid as a precursor to biosensor development [J].
Allum, L. L. ;
Mountfort, D. O. ;
Gooneratne, R. ;
Pasco, N. ;
Goussain, G. ;
Hall, E. A. H. .
TOXICON, 2008, 52 (07) :745-753
[2]   Optimization of intracellular microcystin extraction for their subsequent analysis by high-performance liquid chromatography [J].
Barco, M ;
Lawton, LA ;
Rivera, J ;
Caixach, J .
JOURNAL OF CHROMATOGRAPHY A, 2005, 1074 (1-2) :23-30
[3]   Analysis of cyanobacterial hepatotoxins in water samples by microbore reversed-phase liquid chromatography-electrospray ionisation mass spectrometry [J].
Barco, M ;
Rivera, J ;
Caixach, J .
JOURNAL OF CHROMATOGRAPHY A, 2002, 959 (1-2) :103-111
[4]   High grazer toxicity of [D-Asp3 (E)-Dhb7]microcystin-RR of Planktothrix rubescens as compared to different microcystins [J].
Blom, JF ;
Robinson, JA ;
Jüttner, F .
TOXICON, 2001, 39 (12) :1923-1932
[5]  
Carmichael WW, 1997, ADV BOT RES, V27, P211
[6]   PRODUCTION AND CHARACTERIZATION OF ANTIBODIES AGAINST MICROCYSTINS [J].
CHU, FS ;
HUANG, X ;
WEI, RD ;
CARMICHAEL, WW .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1989, 55 (08) :1928-1933
[7]   Guidance values for microcystins in water and cyanobacterial supplement products (blue-green algal supplements): a reasonable or misguided approach? [J].
Dietrich, D ;
Hoeger, S .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 2005, 203 (03) :273-289
[8]   TISSUE SULFHYDRYL GROUPS [J].
ELLMAN, GL .
ARCHIVES OF BIOCHEMISTRY AND BIOPHYSICS, 1959, 82 (01) :70-77
[9]  
Frobert Y, 1998, METH MOL B, V80, P57
[10]   SCREENING OF MONOCLONAL-ANTIBODIES USING ANTIGENS LABELED WITH ACETYLCHOLINESTERASE - APPLICATION TO THE PERIPHERAL PROTEINS OF PHOTOSYSTEM-1 [J].
GRASSI, J ;
FROBERT, Y ;
LAMOURETTE, P ;
LAGOUTTE, B .
ANALYTICAL BIOCHEMISTRY, 1988, 168 (02) :436-450