Particulate emboli capture by an intra-aortic filter device during aortic valve replacement

被引:4
作者
Leite Filho, Osanan Amorim
de Almeida Brandao, Carlos Manuel
Alberto Pomerantzeff, Pablo Maria
Vieira Guedes, Marco Antonio [1 ]
Higuchi, Maria de Lourdes [2 ]
Groppo Stolf, Noedir Antonio [3 ]
机构
[1] FMUSP, Disciplina Cirurgia Torac & Cardiovasc, Sao Paulo, Brazil
[2] HC FMUSP, Inst Coracao, Serv Anat Patol, Sao Paulo, Brazil
[3] FMUSP, Disciplina Cirurgia Cardiovasc, Sao Paulo, Brazil
来源
REVISTA BRASILEIRA DE CIRURGIA CARDIOVASCULAR | 2008年 / 23卷 / 03期
关键词
Aortic valve stenosis/surgery; Embolism/prevention & control; Stroke/prevention & control; Filtration/instrumentation; Heart valve prosthesis implantation;
D O I
10.1590/S0102-76382008000300026
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: This study aims to analyze the embolic activity in patients with calcified aortic stenosis who underwent aortic valve replacement using intra-aortic filtration with an EMBOL-X(R) System device (Edwards Lifesciences; Inc., Mountain View, CA, USA). Methods: From January 2007 to July 2007, 13 consecutive patients with calcified aortic stenosis, who underwent isolated aortic valve replacement using intra-aortic filtration by an EMBOL-X(R) System for 5 minutes after aortic clamp release, were evaluated. Mean patient age was 63.7 years (range 34 to 79 years) and 61.5% were female. The mean bypass time was 60.2 +/- 7.5 minutes (range 45 to 72 minutes) and the mean cross-clamp time was 50 7.5 minutes (range 35 to 63 minutes). Following removal, each filter was fixed in formalin and analyzed macroscopically with the captured fragments being counted. Histological examinations of the captured material were performed. Results: There were no strokes or gross neurological events. There were no cases of postoperative renal failure. No deaths were reported during hospitalization. Particulate emboli were found in five (38.5%) of the filters. On histological analysis of the particulate emboli captured, two (40%) contained fibrin, two (40%) presented conjunctive tissue, one (20%) contained red blood cells and in one it was not possible to determine the nature of the particulates captured. Conclusion: The EMBOL-X(R) System device was effective in particulate emboli capture in aortic valve replacement surgery of patients with calcified aortic stenosis.
引用
收藏
页码:431 / 435
页数:5
相关论文
共 17 条
  • [1] Emboli capture using the Embol-X IntraAortic filter in cardiac surgery: A multicentered randomized trial of 1,289 patients
    Banbury, MK
    Kouchoukos, NT
    Allen, KB
    Slaughter, MS
    Weissman, NJ
    Berry, GJ
    Horvath, KA
    [J]. ANNALS OF THORACIC SURGERY, 2003, 76 (02) : 508 - 515
  • [2] Barbut D, 1997, ANN THORAC SURG, V63, P1262
  • [3] CEREBRAL EMBOLI DETECTED DURING BYPASS-SURGERY ARE ASSOCIATED WITH CLAMP REMOVAL
    BARBUT, D
    HINTON, RB
    SZATROWSKI, TP
    HARTMAN, GS
    BRUEFACH, M
    WILLIAMSRUSSO, P
    CHARLSON, ME
    GOLD, JP
    [J]. STROKE, 1994, 25 (12) : 2398 - 2402
  • [4] Comparison of transcranial Doppler ultrasonography and transesophageal echocardiography to monitor emboli during coronary artery bypass surgery
    Barbut, D
    Yao, FS
    Hager, DN
    Kavanaugh, P
    Trifiletti, RR
    Gold, JP
    [J]. STROKE, 1996, 27 (01) : 87 - 90
  • [5] Aortic atheroma is related to number of particulates captured by intro-aortic filtration in CABG
    Bergman, P
    Hadjinikolaou, L
    van der Linden, J
    [J]. EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2002, 22 (04) : 539 - 544
  • [6] Bonatti Johannes, 2006, Interact Cardiovasc Thorac Surg, V5, P716, DOI 10.1510/icvts.2005.125971
  • [7] Stroke after cardiac surgery: A risk factor analysis of 16,184 consecutive adult patients
    Bucerius, J
    Gummert, JF
    Borger, MA
    Walther, T
    Doll, N
    Onnasch, JF
    Metz, S
    Falk, V
    Mohr, FW
    [J]. ANNALS OF THORACIC SURGERY, 2003, 75 (02) : 472 - 478
  • [8] Chalmers J, 1999, J HYPERTENS, V17, P151
  • [9] Christenson JT, 2005, TEX HEART I J, V32, P515
  • [10] Capture of particulate emboli during cardiac procedures in which aortic cross-clamp is used
    Harringer, W
    [J]. ANNALS OF THORACIC SURGERY, 2000, 70 (03) : 1119 - 1123