Comparison of Refractive Error Measures by the IRX3 Aberrometer and Autorefraction

被引:12
作者
McCullough, Sara Jayne [1 ]
Little, Julie-Anne [1 ]
Breslin, Karen Mary [1 ]
Saunders, Kathryn Jill [1 ]
机构
[1] Univ Ulster, Vis Sci Res Grp, Sch Biomed Sci, Coleraine BT52 1SA, Londonderry, North Ireland
关键词
refractive error; autorefraction; Shack-Hartmann aberrometry; IRX3; aberrometer; children; NICER Study; NIPPON SRW-5000 AUTOREFRACTOR; MONOCHROMATIC ABERRATIONS; SUBJECTIVE REFRACTION; CLINICAL-EVALUATION; OCULAR ABERRATIONS; REPEATABILITY; CORNEAL; CHILDHOOD; PRECISION; SCHOOLCHILDREN;
D O I
10.1097/OPX.0000000000000379
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose To compare the aberrometry-derived refractive error measurements from the IRX3 aberrometer (Imagine Eyes, Orsay, France) with a standardized measure of refractive error from the Shin-Nippon SRW-5000 (Japan) autorefractor in a large sample of school-aged children. Methods Participants were a subgroup of children from the Northern Ireland Childhood Errors of Refraction Study phase 2 (n = 161 9 to 10 years; n = 147 15 to 16 years). Refractive error was measured under cycloplegia (1.0% cyclopentolate HCl) with the IRX3 aberrometer followed by measurement with the Shin-Nippon autorefractor. Mean differences and 95% confidence intervals and limits of agreement were calculated for refractive vector components (M, J(0), and J(45)). Results Participants had a wide range of refractive error ranging from -6.00 to +8.00 diopters (D) spherical equivalent refraction. Fixed measurement biases (95% confidence interval) between instruments were small for both groups (9- to 10-year-olds: M, -0.20 +/- 0.65 D; J(0), -0.005 D; J(45), 0.05 D; 15- to 16-year-olds: M, 0.03 +/- 0.61 D; J(0), -0.04 D; J(45), -0.02 D). Statistically significant differences were found between instruments for M and J(45) for the 9- to 10-year-old group (p < 0.0001) and for J(0) for the 15- to 16-year-old group (p = 0.003). A statistically significant proportional measurement bias was found for the cylindrical components J(0) and J(45) for both groups (p < 0.0001), but no statistically significant proportional bias was found for M for either group. Conclusions This is the first study to explore refractive error measurements from the IRX3 aberrometer in children. The differences between instruments for all refractive components (M, J(0), and J(45)) were small for both groups (<0.25 D) and may not be considered clinically meaningful. Levels of agreement were also comparable to other studies investigating the validity of instruments measuring automated refraction in both adults and children. The results would suggest that these objective techniques produce similar results for assessment of refractive error in children.
引用
收藏
页码:1183 / 1190
页数:8
相关论文
共 36 条
[1]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[2]   A Prospective Study of Spherical Refractive Error and Ocular Components Among Northern Irish Schoolchildren (The NICER Study) [J].
Breslin, Karen M. M. ;
O'Donoghue, Lisa ;
Saunders, Kathryn J. .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2013, 54 (07) :4843-4850
[3]   Monochromatic aberrations as a function of age, from childhood to advanced age [J].
Brunette, I ;
Bueno, JM ;
Parent, M ;
Hamam, H ;
Simonet, P .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2003, 44 (12) :5438-5446
[4]   Refractive error and monochromatic aberrations in Singaporean children [J].
Carkeet, A ;
Luo, HD ;
Tong, L ;
Saw, SM ;
Tan, DTH .
VISION RESEARCH, 2002, 42 (14) :1809-1824
[5]  
Chat SWS, 2001, OPHTHAL PHYSL OPT, V21, P87, DOI 10.1016/S0275-5408(00)00048-X
[6]   Comparison of refractive error measurements in adults with Z-View aberrometer, Humphrey autorefractor, and subjective refraction [J].
Cooper, Jeffrey ;
Citek, Karl ;
Feldman, Jerome M. .
OPTOMETRY-JOURNAL OF THE AMERICAN OPTOMETRIC ASSOCIATION, 2011, 82 (04) :231-240
[7]   An evaluation of the Bausch & Lomb Zywave aberrometer [J].
Dobos, Michael J. ;
Twa, Michael D. ;
Bullimore, Mark A. .
CLINICAL AND EXPERIMENTAL OPTOMETRY, 2009, 92 (03) :238-245
[8]   Repeatability and validity of Zywave aberrometer measurements [J].
Hament, WJ ;
Nabar, VA ;
Nuijts, RMMA .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2002, 28 (12) :2135-2141
[9]   Seven-Year Changes in Corneal Power and Aberrations after PRK or LASIK [J].
Ivarsen, Anders ;
Hjortdal, Jesper .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2012, 53 (10) :6011-6016
[10]   Higher order wavefront aberrations and topography in early and suspected keratoconus [J].
Jafri, Batool ;
Li, Xiaohui ;
Yang, Huiying ;
Rabinowitz, Yaron S. .
JOURNAL OF REFRACTIVE SURGERY, 2007, 23 (08) :774-781