Effect of anatomical region on the formation of metal artefacts produced by dental implants in cone beam computed tomographic images

被引:30
作者
Machado, Alessiana Helena [1 ]
Castilho Fardim, Karolina Aparecida [1 ]
de Souza, Camila Furtado [1 ]
Sotto-Maior, Bruno Salles [2 ]
Souza Picorelli Assis, Neuza Maria [3 ]
Devito, Karina Lopes [3 ]
机构
[1] Univ Fed Juiz de Fora, Sch Dent, Dent Clin, Juiz De Fora, MG, Brazil
[2] Univ Fed Juiz de Fora, Sch Dent, Dept Restorat Dent, Juiz De Fora, MG, Brazil
[3] Univ Fed Juiz de Fora, Sch Dent, Dept Dent Clin, Juiz De Fora, MG, Brazil
关键词
cone-beam computed tomography; dental implants; artefacts; IN-VITRO ASSESSMENT; TITANIUM; ZIRCONIUM;
D O I
10.1259/dmfr.20170281
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: To quantitatively compare metal artefacts produced by implants in different maxillomandibular regions on cone beam CT (CBCT) images. Methods: A total of 200 implants selected from CBCT examinations were divided into four groups: Group 1 (n = 50)-implants located in the anterior maxilla; Group 2 (n = 50)-implants located in the posterior maxilla; Group 3 (n = 50)-implants located in the anterior mandible and Group 4 (n = 50)-implants located in the posterior mandible. The implants were further classified as isolated or adjacent to other implants. Three axial reconstructions were selected for each sampled implant (apical, middle and cervical). On each slice, the artefacts produced by the implants were counted. The Mann-Whitney test was used to compare the variables between groups. The Kruskal-Wallis and Student-Newman-Keuls tests were used to compare the axial reconstructions. Results: The mandible showed a greater number of artefacts than the maxilla (apical image: p = 0.0024; middle image: p < 0.0001). The anterior region produced more artefacts than the posterior region (apical image: p = 0.0105; middle image: p < 0.0316). There was no significant difference in the number of artefacts between isolated and adjacent implants, and the cervical image was most affected by artefacts. Conclusions: Dental implants always produce metal artefacts in CBCT images, and these artefacts are affected by the anatomical location in the dental arch.
引用
收藏
页数:6
相关论文
共 19 条
  • [1] Cone beam CT scans with and without artefact reduction in root fracture detection of endodontically treated teeth
    Bechara, B.
    McMahan, C. Alex
    Moore, W. S.
    Noujeim, M.
    Teixeira, F. B.
    Geha, H.
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2013, 42 (05)
  • [2] In vitro assessment of artifacts induced by titanium dental implants in cone beam computed tomography
    Benic, Goran I.
    Sancho-Puchades, Manuel
    Jung, Ronald E.
    Deyhle, Hans
    Haemmerle, Christoph H. F.
    [J]. CLINICAL ORAL IMPLANTS RESEARCH, 2013, 24 (04) : 378 - 383
  • [3] Quantitative analysis of metallic artifacts caused by dental metals: comparison of cone-beam and multi-detector row CT scanners
    Chindasombatjaroen, Jira
    Kakimoto, Naoya
    Murakami, Shumei
    Maeda, Yoshinobu
    Furukawa, Souhei
    [J]. ORAL RADIOLOGY, 2011, 27 (02) : 114 - 120
  • [4] Cochran G.W., 1963, Sampling techniques, V2nd
  • [5] Assessment of linear measurements of bone for implant sites in the presence of metallic artefacts using cone beam computed tomography and multislice computed tomography
    Cremonini, C. C.
    Dumas, M.
    Pannuti, C. M.
    Neto, J. B. C.
    Cavalcanti, M. G. P.
    Lima, L. A.
    [J]. INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2011, 40 (08) : 845 - 850
  • [6] Jaju P., 2013, Open Journal of Stomatology, V3, P292, DOI DOI 10.4236/OJST.2013.35049
  • [7] Efficacy of a cone beam computed tomography metal artifact reduction algorithm for the detection of peri-implant fenestrations and dehiscences
    Lins de-Azevedo-Vaz, Sergio
    Peyneau, Priscila Dias
    Ramirez-Sotelo, Laura Ricardina
    Vasconcelos, Karla de Faria
    Flores Campos, Paulo Sergio
    Haiter-Neto, Francisco
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2016, 121 (05): : 550 - 556
  • [8] Tilting the jaw to improve the image quality or to reduce the dose in cone-beam computed tomography
    Luckow, Marlen
    Deyhle, Hans
    Beckmann, Felix
    Dagassan-Berndt, Dorothea
    Mueller, Bert
    [J]. EUROPEAN JOURNAL OF RADIOLOGY, 2011, 80 (03) : E389 - E393
  • [9] The effect of metal artifacts on the identification of vertical root fractures using different fields of view in cone-beam computed tomography
    Moudi, Ehsan
    Haghanifar, Sina
    Madani, Zahrasadat
    Bijani, Ali
    Nabavi, Zeynab Sadat
    [J]. IMAGING SCIENCE IN DENTISTRY, 2015, 45 (03) : 147 - 151
  • [10] Influence of anatomical location on CT numbers in cone beam computed tomography
    Oliveira, Matheus L.
    Tosoni, Guilherme M.
    Lindsey, David H.
    Mendoza, Kristopher
    Tetradis, Sotirios
    Mallya, Sanjay M.
    [J]. ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY, 2013, 115 (04): : 558 - 564