Examination of hemodynamics in patients in hemorrhagic shock undergoing Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA)

被引:18
作者
Wasicek, Philip J. [1 ]
Li, Yao [1 ]
Yang, Shiming [1 ]
Teeter, William A. [1 ]
Scalea, Thomas M. [1 ]
Hu, Peter [1 ]
Brenner, Megan L. [1 ]
机构
[1] Univ Maryland, Sch Med, Program Trauma Crit Care RA Cowley Shock Trauma C, 22 S Greene St, Baltimore, MD 21201 USA
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2019年 / 50卷 / 05期
关键词
Resuscitative Endovascular Balloon; Occlusion of the Aorta; REBOA; Aortic occlusion; Hemodynamics; Blood pressure; LETHAL MODEL; INJURY; TRAUMA;
D O I
10.1016/j.injury.2018.12.030
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The objective of this study was to investigate the hemodynamic effects of aortic occlusion (AO) during Resuscitative Endovascular Balloon Occlusion of the Aorta (REBOA) using a sophisticated continuous vital sign (CVS) monitoring tool. Methods: Patients admitted between February 2013 and May 2017 at a tertiary center that received REBOA were included. Patients in cardiac arrest before or at the time of REBOA were excluded. Time of AO was documented by time-stamped videography and correlated with CVS data. Results: 28 patients were included, mean (standard deviation) ISS was 38 (11). 18 received Zone 1 (distal thoracic aorta) and 10 received Zone 3 (distal abdominal aorta) AO. Among Zone 1 patients the pre-AO systolic blood pressure (SBP) nadir was 64 (19) mmHg, which increased to a mean of 124 (29) mmHg within 5 min after AO (p < 0.01). Among Zone 3 patients the pre-AO SBP nadir was 75 (19) mmHg, which increased to a mean of 98 (14) mmHg within 5 min after AO (p < 0.01). 72% of Zone 1 patients had episodes during AO where SBP was less than 90 mmHg as compared to 80% of Zone 3 patients (p = 0.51). 100% of Zone 1 patients had periods during AO where SBP was greater than 140 mmHg as compared to 70% Zone 3 patients (p = 0.04). The overall mean decrease in SBP after balloon deflation was 13 (20) mmHg (p < 0.01), with similar decreases among groups (14 (21) mmHg vs 12 (18) mmHg for Zone 1 and 3 patients, respectively (p = 0.85)). Patients undergoing Zone 1 AO were more likely to have an acute change (increase or decrease) in their heart rate immediately after AO as compared to Zone 3 AO (p = 0.048). Conclusions: Significant hemodynamic alterations occur before, during, and after AO. The effects of Zone 1 AO on blood pressure and heart rate appear different than Zone 3 AO. This may have important implications for cardiac or cerebral function and perfusion goals, particularly with concomitant injuries such as cardiac contusion or traumatic brain injury. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1042 / 1048
页数:7
相关论文
共 25 条
[1]   Use of Resuscitative Endovascular Balloon Occlusion of the Aorta for Proximal Aortic Control in Patients With Severe Hemorrhage and Arrest [J].
Brenner, Megan ;
Teeter, William ;
Hoehn, Melanie ;
Pasley, Jason ;
Hu, Peter ;
Yang, Shiming ;
Romagnoli, Anna ;
Diaz, Jose ;
Stein, Deborah ;
Scalea, Thomas .
JAMA SURGERY, 2018, 153 (02) :130-135
[2]   Basic endovascular skills for trauma course: Bridging the gap between endovascular techniques and the acute care surgeon [J].
Brenner, Megan ;
Hoehn, Melanie ;
Pasley, Jason ;
Dubose, Joseph ;
Stein, Deborah ;
Scalea, Thomas .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2014, 77 (02) :286-291
[3]   A clinical series of resuscitative endovascular balloon occlusion of the aorta for hemorrhage control and resuscitation [J].
Brenner, Megan L. ;
Moore, Laura J. ;
DuBose, Joseph J. ;
Tyson, George H. ;
McNutt, Michelle K. ;
Albarado, Rondel P. ;
Holcomb, John B. ;
Scalea, Thomas M. ;
Rasmussen, Todd E. .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2013, 75 (03) :506-511
[4]   EFFECT OF ABDOMINAL AORTIC CROSS-CLAMPING ON MYOCARDIAL-FUNCTION [J].
DUNN, E ;
PRAGER, RL ;
FRY, W ;
KIRSH, MM .
JOURNAL OF SURGICAL RESEARCH, 1977, 22 (05) :463-468
[5]   Contemporary outcomes of lower extremity vascular repairs extending below the knee: A multicenter retrospective study [J].
Fortuna, Gerald ;
DuBose, Joseph J. ;
Mendelsberg, Ranan ;
Inaba, Kenji ;
Haider, Ansab ;
Joseph, Bellal ;
Skarupa, David ;
Selleck, Matthew J. ;
O'Callaghan, Thomas A. ;
Charlton-Ouw, Kristofer .
JOURNAL OF TRAUMA AND ACUTE CARE SURGERY, 2016, 81 (01) :63-70
[6]   BLOOD-VOLUME REDISTRIBUTION DURING CROSS-CLAMPING OF THE DESCENDING AORTA [J].
GELMAN, S ;
KHAZAELI, MB ;
ORR, R ;
HENDERSON, T .
ANESTHESIA AND ANALGESIA, 1994, 78 (02) :219-224
[7]  
GELMAN S, 1988, J THORAC CARDIOV SUR, V96, P387
[8]   Reliable Collection of Real-Time Patient Physiologic Data from less Reliable Networks: a "Monitor of Monitors" System (MoMs) [J].
Hu, Peter F. ;
Yang, Shiming ;
Li, Hsiao-Chi ;
Stansbury, Lynn G. ;
Yang, Fan ;
Hagegeorge, George ;
Miller, Catriona ;
Rock, Peter ;
Stein, Deborah M. ;
Mackenzie, Colin F. .
JOURNAL OF MEDICAL SYSTEMS, 2017, 41 (01)
[9]  
Johnson MA, 2017, J TRAUMA ACUTE CARE, V83, P61, DOI [10.1097/TA.0000000000001518, 10.1097/TA.0000000000001372]
[10]   Hemodynamic benefit of positive end-expiratory pressure during acute descending aortic occlusion [J].
Johnston, WE ;
Conroy, BP ;
Miller, GS ;
Lin, CY ;
Deyo, DJ .
ANESTHESIOLOGY, 2002, 97 (04) :875-881