Utility of Real-Time 3-Dimensional Transesophageal Echocardiography in the Assessment of Mitral Paravalvular Leak

被引:12
|
作者
Arribas-Jimenez, Antonio [1 ]
Rama-Merchan, Juan C. [1 ]
Barreiro-Perez, Manuel [1 ]
Merchan-Gomez, Soraya [1 ]
Iscar-Galan, Alberto [1 ]
Martin-Garcia, Ana [1 ]
Nieto-Ballestero, Felix [1 ]
Sanchez-Corral, Esther [1 ]
Rodriguez-Collado, Javier [1 ]
Cruz-Gonzalez, Ignacio [1 ]
Sanchez, Pedro L. [1 ]
机构
[1] Univ Hosp Salamanca, IBSAL, Dept Cardiol, Salamanca 37007, Spain
关键词
Mitral regurgitation; Paravalvular leak; Real-time 3D transesophageal echocardiography; 2D transesophageal echocardiography; PERCUTANEOUS CLOSURE; PERIPROSTHETIC LEAKS; VALVE-REPLACEMENT; REGURGITATION; QUANTIFICATION; PREVALENCE; OUTCOMES; REPAIR;
D O I
10.1253/circj.CJ-15-0802
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Mitral paravalvular leak (PVL) is a potential complication of surgical valve replacement procedures. Real-time 3D transesophageal echocardiography (RT-3DTEE) has emerged as an efficient tool for providing essential information about the anatomy of mitral PVLs compared with 2DTEE findings. The purpose of this study was to evaluate the utility of RT-3DTEE in the assessment of mitral PVLs. Methods and Results: The 3D characteristics of PVLs were recorded and compared with 2D findings. We included 34 consecutive patients with clinical suspicion of mitral PVL in the study. Mitral PVLs were detected in 26 patients (76%); 26 PVLs were identified by 2DTEE and 37 by RT-3DTEE. Moderate or severe mitral regurgitation was present in 23 patients (88%). The most common PVL locations were the septal and posterior regions. The median PVL size measured by RT-3DTEE was 7 mm longx4 mm wide. The median vena contracta of defect measured by 2DTEE and RT-3DTEE was 5 mm and 4 mm, respectively. The median effective regurgitant orifice area of defect measured by RT3-DTEE was 0.36 cm(2). The defect types were "oval" (54%), "round" (35%), "crescentic" (8%) and highly irregular (3%). Conclusions: Compared with 2DTEE, RT-3DTEE provided detailed descriptions of the number, location, size and morphology of PVLs, which is essential for planning and guiding the potential corrective techniques.
引用
收藏
页码:738 / 744
页数:7
相关论文
共 50 条
  • [21] Transcatheter Closure of a Paravalvular Leak Guided by Transesophageal Echocardiography and Three-Dimensional Printing
    Xu, Chennian
    Liu, Yang
    Zhai, Mengen
    Jin, Ping
    Li, Lanlan
    Ma, Yanyan
    Yang, Jian
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [22] Value of Color Doppler Three-Dimensional Transesophageal Echocardiography in the Percutaneous Closure of Mitral Prosthesis Paravalvular Leak
    Biner, Simon
    Kar, Saibal
    Siegel, Robert J.
    Rafique, Asim
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2010, 105 (07) : 984 - 989
  • [23] Intraoperative three-dimensional transesophageal echocardiography for assessing the defect geometries of mitral prosthetic paravalvular leak during transcatheter closure
    Wei, Jeng
    Yin, Wei-Hsian
    Lee, Yung-Tsai
    Hsiung, Ming C.
    Tsai, Shen-Kou
    Chuang, Yi Cheng
    Ou, Ching-Huei
    Chou, Yi-Pen
    JOURNAL OF THE CHINESE MEDICAL ASSOCIATION, 2015, 78 (03) : 158 - 163
  • [24] Amplatzer (R) Vascular Plug III, for closing residual mitral paravalvular leak : three-dimensional transesophageal echocardiography image
    Alberto Reyes-Gomez, Carlos
    Antonio Garcia-Montes, Jose
    Arias-Godinez, Antonio
    Zabal-Cerdeira, Carlos
    ARCHIVOS DE CARDIOLOGIA DE MEXICO, 2015, 85 (03): : 256 - 258
  • [25] Assessment of Global and Regional Left Ventricular Volume and Shape by Real-Time 3-Dimensional Echocardiography in Dogs with Myxomatous Mitral Valve Disease
    Ljungvall, I.
    Hoglund, K.
    Carnabuci, C.
    Tidholm, A.
    Haggstrom, J.
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2011, 25 (05): : 1036 - 1043
  • [26] Comparison of Real-Time Three-Dimensional Transesophageal Echocardiography to Two-Dimensional Transesophageal Echocardiography for Quantification of Mitral Valve Prolapse in Patients With Severe Mitral Regurgitation
    Izumo, Masaki
    Shiota, Maiko
    Kar, Saibal
    Gurudevan, Swaminatha V.
    Tolstrup, Kirsten
    Siegel, Robert J.
    Shiota, Takahiro
    AMERICAN JOURNAL OF CARDIOLOGY, 2013, 111 (04) : 588 - 594
  • [27] Mitral paravalvular leak detected by three-dimensional transoesophageal echocardiography
    Sordi, Martina
    Brochet, Eric
    Messika-Zeitoun, David
    ARCHIVES OF CARDIOVASCULAR DISEASES, 2013, 106 (11) : 627 - 628
  • [28] Effect of Mitral Valve Repair on Mitral-Aortic Coupling: A Real-Time Three-Dimensional Transesophageal Echocardiography Study
    Veronesi, Federico
    Caiani, Enrico G.
    Sugeng, Lissa
    Fusini, Laura
    Tamborini, Gloria
    Alamanni, Francesco
    Pepi, Mauro
    Lang, Roberto M.
    JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2012, 25 (05) : 524 - 531
  • [29] Commissural Prolapse of the Mitral Valve Identified on 3-Dimensional Transesophageal Echocardiography
    Kareti, Kiran
    Storey, John
    Mahenthiran, Jothiharan
    TEXAS HEART INSTITUTE JOURNAL, 2014, 41 (04) : 447 - 448
  • [30] 3D printing from transesophageal echocardiography for planning mitral paravalvular leak closure - feasibility study
    Jedrzejek, Marek
    Peszek-Przybyla, Ewa
    Jadczyk, Tomasz
    Zemik, Jakub
    Piprek, Paulina
    Pysz, Piotr
    Kozlowski, Michal
    Wojakowski, Wojciech
    Smolka, Grzegorz
    POSTEPY W KARDIOLOGII INTERWENCYJNEJ, 2023, 19 (03): : 270 - 276