Prolonged Heterogeneous Liver Enhancement on Contrast-Enhanced Ultrasound

被引:26
作者
Cui, X. W. [1 ]
Ignee, A. [1 ]
Hocke, M. [2 ]
Seitz, K. [3 ]
Schrade, G.
Dietrich, C. F. [1 ]
机构
[1] Univ Wurzburg, Acad Teaching Hosp, Caritas Krankenhaus, Dept Med 2, Bad Mergentheim, Germany
[2] Univ Jena, Acad Teaching Hosp, Hosp Meiningen GmbH, Dept Med 2, Meiningen, Germany
[3] Kreiskrankenhaus Sigmaringen, Med Klin, Sigmaringen, Germany
来源
ULTRASCHALL IN DER MEDIZIN | 2014年 / 35卷 / 03期
关键词
ultrasound; microbubbles; liver; heterogeneous enhancement; PORTAL VENOUS GAS; ENDOSCOPIC ULTRASOUND; DELAYED ENHANCEMENT; DEGUM MULTICENTER; ULTRASONOGRAPHY; LESIONS; GUIDELINES; TUMORS; AGENT; CEUS;
D O I
10.1055/s-0033-1350202
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
Introduction: Prolonged heterogeneous liver enhancement (PHLE) is a rare phenomenon that is similar to the ultrasound findings of portal venous gas. The purpose of this report is to describe the phenomenon of PHLE after the injection of the ultrasound contrast agent SonoVue (R). Patients and Methods: From 2000 to 2013, 13 patients with PHLE ("cloudy", "wool-like") after bolus injection of SonoVue (R) were observed. The height, weight, and body mass index (BMI) of the patients, and the number of injections were analyzed. In addition, the literature was reviewed. Results: The phenomenon occurred as early as 2 minutes after bolus contrast administration and lasted up to 5 hours on both B-mode and contrast-specific ultrasound. 8/13 (62 %) patients received two or more boluses. None of the patients experienced SonoVue (R)-related side effects or health problems. The phenomenon was not reproducible in 3 patients who received a second SonoVue (R) injection 24 hours after receiving the first. Conclusion: This phenomenon is more likely to occur in patients who receive high-dose (or multiple) injections of UCA. It may occur as early as 2 minutes after contrast administration, and therefore, may affect the evaluation of focal liver lesions in the late phase. This phenomenon should not be misdiagnosed as a pathological finding of the liver.
引用
收藏
页码:246 / 252
页数:7
相关论文
共 31 条
[1]   Hepatic portal venous gas: Physiopathology, etiology, prognosis and treatment [J].
Abboud, Bassam ;
El Hachem, Jad ;
Yazbeck, Thierry ;
Doumit, Corinne .
WORLD JOURNAL OF GASTROENTEROLOGY, 2009, 15 (29) :3585-3590
[2]   Unclear Focal Liver Lesions in Contrast-Enhanced Ultrasonography - Lessons to be Learned from the DEGUM Multicenter Study for the Characterization of Liver Tumors [J].
Bernatik, T. ;
Seitz, K. ;
Blank, W. ;
Schuler, A. ;
Dietrich, C. F. ;
Strobel, D. .
ULTRASCHALL IN DER MEDIZIN, 2010, 31 (06) :577-581
[3]   Heterogeneous delayed enhancement of hepatic parenchyma after intravenous infusion of sonographic contrast agent: A new hypothesis [J].
Caruso G. ;
Martegani A. ;
Aiani L. ;
Borghi C. ;
Verderame F. ;
Campisi A. ;
Salvaggio G. ;
Lagalla R. ;
Cardinale A.E. .
La radiologia medica, 2007, 112 (1) :56-63
[4]   Guidelines and Good Clinical Practice Recommendations for Contrast Enhanced Ultrasound (CEUS) in the Liver - Update 2012 A WFUMB-EFSUMB Initiative in Cooperation With Representatives of AFSUMB, AIUM, ASUM, FLAUS and ICUS [J].
Claudon, M. ;
Dietrich, C. F. ;
Choi, B. I. ;
Cosgrove, D. O. ;
Kudo, M. ;
Nolsoe, C. P. ;
Piscaglia, F. ;
Wilson, S. R. ;
Barr, R. G. ;
Chammas, M. C. ;
Chaubal, N. G. ;
Chen, M. -H. ;
Clevert, D. A. ;
Correas, J. M. ;
Ding, H. ;
Forsberg, F. ;
Fowlkes, J. B. ;
Gibson, R. N. ;
Goldberg, B. B. ;
Lassau, N. ;
Leen, E. L. S. ;
Mattrey, R. F. ;
Moriyasu, F. ;
Solbiati, L. ;
Weskott, H. -P. ;
Xu, H. -X. .
ULTRASCHALL IN DER MEDIZIN, 2013, 34 (01) :11-29
[5]   Focal liver lesion, incidental finding [J].
Dietrich, C. F. ;
Jenssen, C. .
DEUTSCHE MEDIZINISCHE WOCHENSCHRIFT, 2012, 137 (41) :2099-2112
[6]   EFSUMB Guidelines 2011: Comments and Illustrations [J].
Dietrich, C. F. ;
Cui, X. W. ;
Schreiber-Dietrich, D. G. ;
Ignee, A. .
ULTRASCHALL IN DER MEDIZIN, 2012, 33 :S11-S21
[7]   EFSUMB Guidelines 2011: Comment on Emergent Indications and Visions [J].
Dietrich, C. F. ;
Cui, X. W. ;
Barreiros, A. P. ;
Hocke, M. ;
Ignee, A. .
ULTRASCHALL IN DER MEDIZIN, 2012, 33 :S39-S47
[8]   Liver Tumor Characterization - Review of the Literature [J].
Dietrich, C. F. ;
Maddalena, M. E. ;
Cui, X. W. ;
Schreiber-Dietrich, D. ;
Ignee, A. .
ULTRASCHALL IN DER MEDIZIN, 2012, 33 :S3-S10
[9]   Contrast-Enhanced Ultrasound for Imaging of Adrenal Masses [J].
Dietrich, C. F. ;
Ignee, A. ;
Barreiros, A. P. ;
Schreiber-Dietrich, D. ;
Sienz, M. ;
Bojunga, J. ;
Braden, B. .
ULTRASCHALL IN DER MEDIZIN, 2010, 31 (02) :163-168
[10]   Contrast-enhanced endoscopic ultrasound with low mechanical index: A new technique [J].
Dietrich, CF ;
Ignee, A ;
Frey, H .
ZEITSCHRIFT FUR GASTROENTEROLOGIE, 2005, 43 (11) :1219-1223