Transmission-Line Fault Analysis Using Synchronized Sampling

被引:65
作者
Dutta, Papiya [1 ]
Esmaeilian, Ahad [1 ]
Kezunovic, Mladen [1 ]
机构
[1] Texas A&M Univ, Dept Elect & Comp Engn, College Stn, TX 77843 USA
关键词
Electromagnetic transients; fault detection; fault location; power system faults; power system protection; DETECTION/LOCATION TECHNIQUE; PART I; CLASSIFICATION; ALGORITHMS; LOCATOR; RELAY; END;
D O I
10.1109/TPWRD.2013.2296788
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An automated analysis approach, which can automatically characterize fault and subsequent relay operation, is the focus of this paper. It utilizes synchronized samples captured during transients from both ends of the transmission line to detect, classify, and locate transmission-line faults and can verify that the tripped line has indeed experienced a fault. The proposed method is tested for several faults simulated on an IEEE 118-bus test system and it has been concluded that it can detect and classify a fault using prefault and postfault recorded samples within 7 ms of fault inception and can accurately locate a fault with 3% accuracy. This time response performance is highly desirable since with the increasing use of modern circuit breakers, which can open the faulty line in less than two cycles, the time window of the captured waveforms is significantly reduced due to the unavailability of measurement signals after breakers open.
引用
收藏
页码:942 / 950
页数:9
相关论文
共 23 条
[1]  
[Anonymous], C371442004 IEEE
[2]   Fuzzy-logic-based fault classification scheme for digital distance protection [J].
Das, B ;
Reddy, JV .
IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) :609-616
[3]  
EMTP, 2010, ALT TRANS PROGR
[4]   AN ACCURATE FAULT LOCATOR WITH COMPENSATION FOR APPARENT REACTANCE IN THE FAULT RESISTANCE RESULTING FROM REMOTE-END INFEED [J].
ERIKSSON, L ;
SAHA, MM ;
ROCKEFELLER, GD .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1985, 104 (02) :424-436
[5]  
Gigris A. A., 1992, IEEE T POWER DELIVER, V7, P98
[6]   A NEW KALMAN FILTERING BASED DIGITAL DISTANCE RELAY [J].
GIRGIS, AA .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1982, 101 (09) :3471-3480
[7]   Fault location using the distributed parameter transmission line model [J].
Gopalakrishnan, A ;
Kezunovic, M ;
McKenna, SM ;
Hamai, DM .
IEEE TRANSACTIONS ON POWER DELIVERY, 2000, 15 (04) :1169-1174
[8]   Locating faults in parallel transmission lines under availability of complete measurements at one end [J].
Izykowski, J ;
Rosolowski, E ;
Saha, MM .
IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2004, 151 (02) :268-273
[9]  
Jiang JA, 2000, IEEE T POWER DELIVER, V15, P486
[10]   ACCURATE FAULT LOCATION TECHNIQUE FOR POWER TRANSMISSION-LINES [J].
JOHNS, AT ;
JAMALI, S .
IEE PROCEEDINGS-C GENERATION TRANSMISSION AND DISTRIBUTION, 1990, 137 (06) :395-402