Comparison of independent Monte Carlo calculations with measurements of spot scanned proton fields

被引:0
|
作者
Fredh, A. [1 ]
Winterhalter, C. [1 ]
Fura, E. [1 ]
Bolsi, A. [1 ]
Safai, S. [1 ]
Weber, D. [1 ]
Lomax, A. [1 ]
机构
[1] Paul Scherrer Inst, Ctr Proton Therapy, Villigen, Switzerland
关键词
D O I
10.1016/S0167-8140(18)32124-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
EP-1815
引用
收藏
页码:S977 / S977
页数:1
相关论文
共 50 条
  • [1] Monte Carlo dose calculations for spot scanned proton therapy
    Tourovsky, A
    Lomax, AJ
    Schneider, U
    Pedroni, E
    PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (05): : 971 - 981
  • [2] Monte Carlo and analytical dose calculations for proton spot scanning
    Bues, M
    Ciangaru, G
    Smith, A
    MEDICAL PHYSICS, 2004, 31 (06) : 1902 - 1903
  • [3] ABSORBED DOSE MEASUREMENTS AT AN 800 GEV PROTON ACCELERATOR - COMPARISON WITH MONTE-CARLO CALCULATIONS
    COSSAIRT, JD
    BUTALA, SW
    GERARDI, MA
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1985, 238 (2-3): : 504 - 508
  • [4] ABSORBED DOSE MEASUREMENTS AT AN 800 GEV PROTON ACCELERATOR - COMPARISON WITH MONTE-CARLO CALCULATIONS
    COSSAIRT, JD
    BUTALA, SW
    GERARDI, MA
    HEALTH PHYSICS, 1985, 49 (01): : 153 - 153
  • [5] Confining proton beams with longitudinal magnetic fields: Monte Carlo calculations
    Nardi, E
    Schulte, R
    MEDICAL PHYSICS, 2000, 27 (10) : 2369 - 2371
  • [6] Comparison of Measurements and Eclipse Electron Monte Carlo Calculations for Small Electron Fields with Central Block
    Ivanova, T.
    Kassaee, A.
    MEDICAL PHYSICS, 2010, 37 (06) : 3263 - +
  • [7] Electron Monte Carlo Comparison to Hand Calculations and Phantom Measurements
    Chu, K.
    Potari, V.
    Rostock, R.
    DeLuca, M.
    MEDICAL PHYSICS, 2018, 45 (06) : E250 - E250
  • [8] Comparison of treatment planning dose calculations with measurements and Monte Carlo calculations in a RANDO phantom
    Wyatt, M
    Corredor, C
    Tamimi, M
    Miller, LF
    RADIATION PROTECTION DOSIMETRY, 2005, 116 (1-4) : 461 - 465
  • [9] Monte Carlo calculations for absolute dosimetry to determine machine outputs for proton therapy fields
    Paganetti, Harald
    PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (11): : 2801 - 2812
  • [10] A Comparison between Pencil Beam and Monte Carlo Algorithms Against Film Measurements in an Anthropomorphic Phantom for Proton Spot Scanning
    Saini, J.
    Maes, D.
    Bowen, S. R.
    Egan, A. J.
    Bloch, C.
    Wong, T. P.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2017, 99 (02): : E717 - E718