Thoracolumbar proprioception in individuals with and without low back pain: Intratester reliability, clinical applicability, and validity

被引:57
作者
Koumantakis, GA
Winstanley, J
Oldham, JA
机构
[1] Univ Manchester, Cent Manchester Healthcare Trust, Ctr Rehabil Sci, Manchester M13 9WL, Lancs, England
[2] Univ Sydney, Royal Rehabil Ctr, Rehabil Studies Unit, Ryde, NSW, Australia
关键词
electrogoniometer; muscle spindle; neuromuscular dysfunction; position sense;
D O I
10.2519/jospt.2002.32.7.327
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Study Design: Repeated measures design of active spinal position sense in individuals with and without low back pain (LBP). Objectives: Reproducibility and validity evaluation of thoracolumbar proprioception measurement. Background: Proprioception studies in peripheral joints and the spine suggest that there may be proprioception deficits due to injury, pain, or degeneration. Kinesthetic retraining may be useful in rehabilitation of patients with LBP, but appropriate measures are required to objectively quantify spinal proprioception. Methods and Measures: Active-target reproduction in the sagittal, horizontal, and coronal planes was assessed (3 separate occasions for 18 asymptomatic volunteers and 2 occasions for 62 patients with LBP). Repositioning accuracy was expressed as absolute errors (AE) and variable errors (VE). Reliability was analyzed with intraclass correlation coefficient (ICC) and precision with standard error of measurement (SEM) and calculation of the smallest detectable difference (SDD) index. Repeated measures ANOVA and correlations were used for within-group comparisons and discriminant analysis for between-group comparisons. Results: Reproducibility was better for the asymptomatic group, with AE for flexion and rotation being the most reliable (ICC = 0.76-0.80, SEM = 0.91degrees-1.34degrees). SDDs were high for all tests, suggesting limited clinical applicability. Reproducibility for the same tests was poor-moderate (ICC = 0.31-0.64, SEM = 0.45degrees-3.90degrees) for the patient group. AE for right-side rotation could discriminate between subject groups with 83.3% specificity but only 54.8% sensitivity. Conclusions: Proprioception testing, with the methods employed, did not demonstrate good measurement properties in a sample of patients with recurrent LBP. Neither could it sufficiently discriminate between individuals with and without LBP. Possible reasons for these findings are discussed.
引用
收藏
页码:327 / 335
页数:9
相关论文
共 49 条
[1]  
ALEXANDER M, 1998, CRIT REV PHYS REHABI, V10, P15
[2]  
[Anonymous], CRIT REV PHYS REHABI
[3]   The influence of low back pain on muscle activity and coordination during gait: A clinical and experimental study [J].
ArendtNielsen, L ;
GravenNielsen, T ;
Svarrer, H ;
Svensson, P .
PAIN, 1996, 64 (02) :231-240
[4]   Effect of paraspinal muscle vibration on position sense of the lumbosacral spine [J].
Brumagne, S ;
Lysens, R ;
Swinnen, S ;
Verschueren, S .
SPINE, 1999, 24 (13) :1328-1331
[5]   The role of paraspinal muscle spindles in lumbosacral position sense in individuals with and without low back pain [J].
Brumagne, S ;
Cordo, P ;
Lysens, R ;
Verschueren, S ;
Swinnen, S .
SPINE, 2000, 25 (08) :989-994
[6]   Lumbosacral position sense during pelvic tilting in men and women without low back pain: Test development and reliability assessment [J].
Brumagne, S ;
Lysens, R ;
Spaepen, A .
JOURNAL OF ORTHOPAEDIC & SPORTS PHYSICAL THERAPY, 1999, 29 (06) :345-351
[7]   Lumbosacral repositioning accuracy in standing posture: a combined electrogoniometric and videographic evaluation [J].
Brumagne, S ;
Lysens, R ;
Spaepen, A .
CLINICAL BIOMECHANICS, 1999, 14 (05) :361-363
[8]  
Cavanaugh JM, 1997, CLIN ORTHOP RELAT R, P166
[9]  
Clinical Standards Advisory Group Committee, 1994, BACK PAIN REP CSAG C
[10]  
CURRIER D, 1990, ELEMENTS RES PHYSICA