Determination of the size of a foreign body in the eye using image analysis of its roentgenogram

被引:0
作者
Pilin, A
Pudil, F
Horejs, J
Brany, J
机构
[1] Univ Hosp, Inst Forens Med, Prague 12800 2, Czech Republic
[2] Inst Chem Technol, Dept Food Anal, Prague 16000 6, Czech Republic
[3] Univ Hosp, Dept Radiol, Radiodiagnost Clin, Prague 12800 2, Czech Republic
[4] Police Czech Republ Dist Bur Invest, Pribram, Czech Republic
关键词
forensic science; forensic pathology; shotgun injury; eye; foreign body; pellet size; X-ray; image analysis;
D O I
暂无
中图分类号
DF [法律]; D9 [法律]; R [医药、卫生];
学科分类号
0301 ; 10 ;
摘要
The case of a computer-enhanced image analysis of X-ray pictures of a pellet in the orbit of a man who sustained a shotgun injury to his right eyeball is presented. The man was shot accidentally during a pheasant hunt. Two hunters were shooting simultaneously but they were using three different sizes of pellet-3.0, 3.5 and 4.0 mm. One of the pellets hit a third man in the eye. He sustained serious injury with a resultant loss of sight in this eye despite immediate medical treatment. Unfortunately the pellet could not be removed from the orbit, but it was necessary to establish who was responsible for the injury. The problem lay in determining the specification and size of the pellet at that moment. The problem was solved using computer-enhanced video image analysis of the X-ray pictures of the pellets. The image processor LUCIA G (http//www.lim.cz) was used.
引用
收藏
页码:214 / 219
页数:6
相关论文
共 7 条
  • [1] PARTICLE-SIZE DETERMINATION BY AUTOMATED MICROSCOPIC IMAGING ANALYSIS WITH COMPARISON TO LASER DIFFRACTION
    BREWER, E
    RAMSLAND, A
    [J]. JOURNAL OF PHARMACEUTICAL SCIENCES, 1995, 84 (04) : 499 - 501
  • [2] Detection and localization of steel intraocular foreign bodies using computed tomography - A comparison of helical and conventional axial scanning
    Chacko, JG
    Figueroa, RE
    Johnson, MH
    Marcus, DM
    Brooks, SE
    [J]. OPHTHALMOLOGY, 1997, 104 (02) : 319 - 323
  • [3] *LAB IM SRO, LUC M VERS 3 0 US GU
  • [4] PETTERSSON H, 1995, GLOBAL TXB RADIOLOGY
  • [5] Evaluation of soft-tissue foreign bodies: Comparing conventional plain film radiography, computed radiography printed on film, and computed radiography displayed on a computer workstation
    Reiner, B
    Siegel, E
    McLaurin, T
    Pomerantz, S
    Allman, R
    Hebel, JR
    Fritz, S
    Protopapas, Z
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1996, 167 (01) : 141 - 144
  • [6] THE DETECTION OF FOREIGN-BODIES IN SOFT-TISSUE - COMPARISON OF CONVENTIONAL AND DIGITAL RADIOGRAPHY
    ROOBOTTOM, CA
    WESTON, MJ
    [J]. CLINICAL RADIOLOGY, 1994, 49 (05) : 330 - 332
  • [7] Serra J., 1982, Image Analysis and Mathematical Morphology