Technological Advancements in Echocardiographic Assessment of Thoracic Aortic Dilatation: Head to Head Comparison Among Multidetector Computed Tomography, 2-Dimensional, and 3-Dimensional Echocardiography Measurements

被引:12
|
作者
Ali, Sarah Ghulam [1 ]
Fusini, Laura [1 ]
Dalla Cia, Alessia [1 ]
Tamborini, Gloria [1 ]
Gripari, Paola [1 ]
Muratori, Manuela [1 ]
Mancini, Maria E. [1 ]
Annoni, Andrea [1 ]
Formenti, Alberto [1 ]
Pepi, Mauro [1 ]
机构
[1] Ctr Cardiol Monzino IRCCS, Via Parea 4, Milan, Italy
关键词
thoracic aorta dilatation; echocardiography; computed tomography; TRANSTHORACIC ECHOCARDIOGRAPHY; REFERENCE VALUES; ASCENDING AORTA; ROOT DIMENSIONS; BODY-SIZE; RECOMMENDATIONS; DISEASES; ADULTS; EDGE;
D O I
10.1097/RTI.0000000000000330
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose:The aim of this study was to evaluate the feasibility and accuracy of 2-dimensional (2D) and 3-dimensional (3D) transthoracic echocardiography (2DTTE, 3DTTE) versus multidetector computed tomography (MDCT) in patients with ascending aortic (AA) dilation.Materials and Methods:Fifty consecutive patients with AA dilation were evaluated by 2DTTE, X-plane (XP) 3DTTE, and MDCT. Aorta diameters were measured at aortic annulus, aortic root (SIN), sinotubular junction, AA, aortic arch before the prebrachiocephalic artery (PRE), and before left subclavian artery (INTRA). Leading edge-to-leading edge (L-L) and inner-to-inner (I-I) measurements were compared with MDCT data.Results:Feasibility, quality of imaging, and accuracy was high with all echocardiographic methods. Specifically for MDCT maximum SIN diameter, the best correlation and agreement was obtained using XP maximum diameter at 3DTTE (MDCT: 44.87.4mm vs. XP: 44.4 +/- 7.4mm; r=0.975; bias=-0.4mm). The same was true for AA maximum diameter at MDCT (MDCT: 46.6 +/- 8.1mm vs. XP: 47.5 +/- 8.1mm; r=0.991; bias=0.1mm). For aortic arch the best correlation and agreement with MDCT were as follows: 2DTTE L-L diameter for arch PRE (MDCT: 37.9 +/- 5.3mm vs. TTE: 36.6 +/- 4.5mm; r=0.927; bias=-0.9mm) and MDCT minimum diameter with XP minimum diameter for arch INTRA (MDCT: 28.2 +/- 5.0mm vs. TTE 28.8 +/- 4.7mm; r=0.939; bias=-0.3mm).Conclusion:In patients with aortic dilatation or aneurysm, new techniques (mainly 2D-3D probes allowing XP views) facilitate accuracy of aortic measurements at different sites of the vessel and allow standardization of analysis to better compare with MDCT.
引用
收藏
页码:232 / 239
页数:8
相关论文
共 30 条
  • [1] Multimodality Assessment of Thoracic Aortic Dimensions Comparison of Computed Tomography Angiography, Magnetic Resonance Imaging, and Echocardiography Measurements
    Frazao, Caio
    Tavoosi, Anahita
    Wintersperger, Bernd J.
    Nguyen, Elsie T.
    Wald, Rachel M.
    Ouzounian, Maral
    Hanneman, Kate
    JOURNAL OF THORACIC IMAGING, 2020, 35 (06) : 399 - 406
  • [2] Head-to-Head Comparison of Left Ventricular Function Assessment with 64-Row Computed Tomography, Biplane Left Cineventriculography, and Both 2- and 3-Dimensional Transthoracic Echocardiography Comparison With Magnetic Resonance Imaging as the Reference Standard
    Greupner, Johannes
    Zimmermann, Elke
    Grohmann, Andrea
    Duebel, Hans-Peter
    Althoff, Till
    Borges, Adrian C.
    Rutsch, Wolfgang
    Schlattmann, Peter
    Hamm, Bernd
    Dewey, Marc
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2012, 59 (21) : 1897 - 1907
  • [3] Three-Dimensional Multidetector Computed Tomography versus Conventional 2-Dimensional Transesophageal Echocardiography for Annular Sizing in Transcatheter Aortic Valve Replacement: Influence on Postprocedural Paravalvular Aortic Regurgitation
    Hansson, Nicolaj C.
    Thuesen, Leif
    Hjortdal, Vibeke E.
    Leipsic, Jonathon
    Andersen, Henning R.
    Poulsen, Steen H.
    Webb, John G.
    Christiansen, Evald H.
    Rasmussen, Lars E.
    Krusell, Lars R.
    Terp, Kim
    Klaaborg, Kaj E.
    Tang, Mariann
    Lassen, Jens F.
    Botker, Hans E.
    Norgaard, Bjarne L.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 82 (06) : 977 - 986
  • [4] 3-DIMENSIONAL COMPUTED-TOMOGRAPHY IN THE HEAD AND NECK DISEASES WITH BONY ABNORMALITIES
    TOMURA, N
    MIYAUCHI, T
    SHINDO, M
    SEINO, Y
    WATANABE, M
    MIURA, H
    WATARAI, J
    KATO, T
    TOGAWA, K
    KOWADA, M
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1993, 17 (06) : 411 - 420
  • [5] Aortic Annular Sizing Using a Novel 3-Dimensional Echocardiographic Method Use and Comparison With Cardiac Computed Tomography
    Khalique, Omar K.
    Kodali, Susheel K.
    Paradis, Jean-Michel
    Nazif, Tamim M.
    Williams, Mathew R.
    Einstein, Andrew J.
    Pearson, Gregory D.
    Harjai, Kishore
    Grubb, Kendra
    George, Isaac
    Leon, Martin B.
    Hahn, Rebecca T.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2014, 7 (01) : 155 - 163
  • [6] Comparison of Aortic Root Dimensions and Geometries Before and After Transcatheter Aortic Valve Implantation by 2-and 3-Dimensional Transesophageal Echocardiography and Multislice Computed Tomography
    Ng, Arnold C. T.
    Delgado, Victoria
    van der Kley, Frank
    Shanks, Miriam
    van de Veire, Nico R. L.
    Bertini, Matteo
    Nucifora, Gaetano
    van Bommel, Rutger J.
    Tops, Laurens F.
    de Weger, Arend
    Tavilla, Giuseppe
    de Roos, Albert
    Kroft, Lucia J.
    Leung, Dominic Y.
    Schuijf, Joanne
    Schalij, Martin J.
    Bax, Jeroen J.
    CIRCULATION-CARDIOVASCULAR IMAGING, 2010, 3 (01) : 94 - 102
  • [7] Three-dimensional demonstration of bicuspid aortic valve by 16-row multidetector computed tomography: comparison with transesophageal echocardiography
    Niinuma, H
    Yoshioka, K
    Ogino, Y
    Kawazoe, K
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2005, 27 (02) : 346 - 346
  • [8] Influence of the Quantity of Aortic Valve Calcium on the Agreement Between Automated 3-Dimensional Transesophageal Echocardiography and Multidetector Row Computed Tomography for Aortic Annulus Sizing
    Podlesnikar, Tomaz
    Prihadi, Edgard A.
    van Rosendael, Philippe J.
    Vollema, E. Mara
    van der Kley, Frank
    de Weger, Arend
    Marsan, Nina Ajmone
    Naji, Franjo
    Fras, Zlatko
    Bax, Jeroen J.
    Delgado, Victoria
    AMERICAN JOURNAL OF CARDIOLOGY, 2018, 121 (01): : 86 - 93
  • [9] Correlation of 2-Dimensional and 3-Dimensional Echocardiographic Analysis to Surgical Measurements of the Tricuspid Valve Annular Diameter
    Bhatt, Himani, V
    Spivack, John
    Patel, Pritul R.
    El-Eshmawi, Ahmed
    Amir, Yasmin
    Adams, David H.
    Fischer, Gregory W.
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (01) : 137 - 145
  • [10] Comparison of Left Atrial Measurements Using 2-and 3-Dimensional Transesophageal Echocardiography
    Kwak, Jenny
    Polito, Andrea
    Majewski, Michael
    Adams, William
    Burcar, Kimberly
    Oftadeh, Mina
    Haske, Michael
    LeVan, Pierre
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2019, 33 (06) : 1518 - 1526