Delayed febrile response with bloodstream infections in patients with continuous-flow left ventricular assist devices

被引:2
作者
Wrobel, Christopher A. [1 ]
Drazner, Mark H. [2 ]
Ayers, Colby R. [2 ]
Pham, David D. [2 ]
La Hoz, Ricardo M. [3 ]
Grodin, Justin L. [2 ]
Garg, Sonia [2 ]
Mammen, Pradeep P. A. [2 ]
Morlend, Robert M. [2 ]
Araj, Faris [2 ]
Amin, Alpesh A. [2 ]
Cornwell, William K. [2 ]
Thibodeau, Jennifer T. [2 ]
机构
[1] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Dallas, TX USA
[2] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Div Cardiol, Dallas, TX 75390 USA
[3] Univ Texas Southwestern Med Ctr Dallas, Dept Internal Med, Div Infect Dis, Dallas, TX USA
基金
美国国家卫生研究院;
关键词
HEART-FAILURE; CIRCULATING LEVELS; RISK-FACTORS; IMPLANTATION; INFLAMMATION; ACTIVATION; THROMBOSIS; RECIPIENTS; CYTOKINES; SYSTEM;
D O I
10.1136/jim-2018-000893
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Bloodstream infections (BSIs) are common in patients with continuous-flow left ventricular assist devices (CF-LVADs). Whether CF-LVADs modulate the febrile response to BSIs is unknown. We retrospectively compared the febrile response to BSIs in patients with heart failure (HF) with CF-LVADs versus a control population of patients with HF receiving inotropic infusions. BSIs were adjudicated using the Centers for Disease Control and Prevention and the National Healthcare Safety Network criteria. Febrile status (temperature >= 38 degrees C, 100.4 degrees F), temperature at presentation with BSI, and the highest temperature within 72 hours (Tmax) were collected. We observed 59 BSIs in LVAD patients and 45 BSIs in controls. LVAD patients were more likely to be afebrile and to have a lower temperature at presentation than control (88% vs 58%, p=0.002, and 37 degrees C +/- 0.7 vs 37.7 degrees C +/- 1.0, p=0.0009, respectively). By 72 hours, the difference in afebrile status diminished (53% vs 44%, p=0.42), and the Tmax was similar between the LVAD and control groups (37.9 degrees C +/- 0.9 vs 38.2 degrees C +/- 0.8, respectively, p=0.10). In conclusion, at presentation with a BSI, the vast majority of CF-LVAD patients were afebrile, an event which occurred at a higher frequency when compared with patients with advanced HF on chronic inotropes via an indwelling venous catheter. These data alert clinicians to have a very low threshold to obtain blood cultures in CF-LVAD patients even in the absence of fever. Further study is needed to determine whether a delayed or diminished febrile response represents another pathophysiological consequence of CF-LVADs.
引用
收藏
页码:653 / 658
页数:6
相关论文
共 50 条
[41]   Quantitative Assessment of Inflow Malposition in Two Continuous-Flow Left Ventricular Assist Devices [J].
Sorensen, Erik N. ;
Kon, Zachary N. ;
Feller, Erika D. ;
Pham, Si M. ;
Griffith, Bartley P. .
ANNALS OF THORACIC SURGERY, 2018, 105 (05) :1377-1383
[42]   Contemporary outcomes of continuous-flow left ventricular assist devices-a systematic review [J].
McNamara, Nicholas ;
Narroway, Harry ;
Williams, Michael ;
Brookes, John ;
Farag, James ;
Cistulli, David ;
Bannon, Paul ;
Marasco, Silvana ;
Potapov, Evgenij ;
Loforte, Antonio .
ANNALS OF CARDIOTHORACIC SURGERY, 2021, 10 (02) :186-208
[43]   Histologic analysis of clots in explanted axial continuous-flow left ventricular assist devices [J].
Prasad, Sunil M. ;
Robertson, Jason O. ;
Itoh, Akinobu ;
Joseph, Susan M. ;
Silvestry, Scott C. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2015, 34 (04) :616-618
[44]   Continuous-Flow Left Ventricular Assist Device Implantation in Patients With a Small Left Ventricle [J].
Kawabori, Masashi ;
Kurihara, Chitaru ;
Sugiura, Tadahisa ;
Cohn, William E. ;
Civitello, Andrew B. ;
Frazier, O. Howard ;
Morgan, Jeffrey A. .
ANNALS OF THORACIC SURGERY, 2018, 105 (03) :799-806
[45]   Predictors and Clinical Impact of Late Ventricular Arrhythmias in Patients With Continuous-Flow Left Ventricular Assist Devices [J].
Galand, Vincent ;
Flecher, Erwan ;
Auffret, Vincent ;
Boule, Stephane ;
Vincentelli, Andre ;
Dambrin, Camille ;
Mondoly, Pierre ;
Sacher, Frederic ;
Nubret, Karine ;
Kindo, Michel ;
Cardi, Thomas ;
Gaudard, Philippe ;
Rouviere, Philippe ;
Michel, Magali ;
Gourraud, Jean-Baptiste ;
Defaye, Pascal ;
Chavanon, Olivier ;
Verdonk, Constance ;
Ghodbane, Walid ;
Pelce, Edeline ;
Gariboldi, Vlad ;
Pozzi, Matteo ;
Obadia, Jean-Francois ;
Litzler, Pierre-Yves ;
Anselme, Frederic ;
Babatasi, Gerard ;
Belin, Annette ;
Garnier, Fabien ;
Bielefeld, Marie ;
Hamon, David ;
Radu, Costin ;
Pierre, Bertrand ;
Bourguignon, Thierry ;
Eschalier, Romain ;
D'Ostrevy, Nicolas ;
Bories, Marie-Cecile ;
Marijon, Eloi ;
Vanhuyse, Fabrice ;
Blangy, Hugues ;
Verhoye, Jean-Philippe ;
Leclercq, Christophe ;
Martins, Raphael P. .
JACC-CLINICAL ELECTROPHYSIOLOGY, 2018, 4 (09) :1166-1175
[46]   Bloodstream Infections in Continuous Flow Left Ventricular Assist Device Recipients: Diagnostic and Clinical Implications [J].
Kyvernitakis, Andreas ;
Pappas, Orestis ;
Farmakiotis, Dimitrios ;
Horn, Edward T. ;
Benza, Raymond L. ;
Bailey, Stephen H. ;
Agarwal, Richa .
ASAIO JOURNAL, 2019, 65 (08) :798-805
[47]   Patients With Continuous-Flow Left Ventricular Assist Devices Provide Insight in Human Baroreflex Physiology [J].
Tank, Jens ;
Heusser, Karsten ;
Malehsa, Doris ;
Hegemann, Katrin ;
Haufe, Sven ;
Brinkmann, Julia ;
Tegtbur, Uwe ;
Diedrich, Andre ;
Bara, Christoph ;
Jordan, Jens ;
Strueber, Martin .
HYPERTENSION, 2012, 60 (03) :849-855
[48]   Dosing of vancomycin in patients with continuous-flow left ventricular assist devices: A clinical pharmacokinetic analysis [J].
Jennings, Douglas L. ;
Makowski, Charles T. ;
Chambers, Rachel M. ;
Lanfear, David E. .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2014, 37 (03) :270-274
[49]   The Incidence, Risk, and Consequences of Atrial Arrhythmias in Patients with Continuous-Flow Left Ventricular Assist Devices [J].
Brisco, Meredith A. ;
Sundareswaran, Kartik S. ;
Milano, Carmelo A. ;
Feldman, David ;
Testani, Jeffrey M. ;
Ewald, Gregory A. ;
Slaughter, Mark S. ;
Farrar, David J. ;
Goldberg, Lee R. .
JOURNAL OF CARDIAC SURGERY, 2014, 29 (04) :572-580
[50]   Effect of obesity on outcomes in patients undergoing implantation of continuous-flow left ventricular assist devices [J].
Volkovicher, Nastasya ;
Kurihara, Chitaru ;
Critsinelis, Andre ;
Kawabori, Masashi ;
Sugiura, Tadahisa ;
Manon, Marcos, II ;
Civitello, Andrew B. ;
Morgan, Jeffrey A. .
JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (02) :180-187