Dual-Energy CT in Patients Suspected of Having Renal Masses: Can Virtual Nonenhanced Images Replace True Nonenhanced Images?

被引:330
作者
Graser, Anno [1 ,3 ]
Johnson, Thorsten R. C. [1 ]
Hecht, Elizabeth M. [3 ]
Becker, Christoph R. [1 ]
Leidecker, Christianne [4 ]
Staehler, Michael [2 ]
Stief, Christian G. [2 ]
Hildebrandt, Henriette [1 ]
Godoy, Myrna C. B. [3 ]
Finn, Myra E. [3 ]
Stepansky, Flora [3 ]
Reiser, Maximilian F. [1 ]
Macari, Michael [3 ]
机构
[1] Univ Munich, Dept Clin Radiol, D-81377 Munich, Germany
[2] Univ Munich, Dept Urol, D-81377 Munich, Germany
[3] NYU, Dept Radiol, Sch Med, New York, NY 10016 USA
[4] Siemens Med Solut, Malvern, PA USA
关键词
D O I
10.1148/radiol.2522080557
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To qualitatively and quantitatively compare virtual nonenhanced (VNE) data sets derived from dual-energy (DE) computed tomography (CT) with true nonenhanced (TNE) data sets in the same patients and to calculate potential radiation dose reductions for a dual-phase renal multidetector CT compared with a standard triple-phase protocol. Materials and Methods: This prospective study was approved by the institutional review board; all patients provided written informed consent. Seventy one men (age range, 30-88 years) and 39 women (age range, 22-87 years) underwent preoperative DE CT that included unenhanced, DE nephrographic, and delayed phases. DE CT parameters were 80 and 140 kV, 96 mAs (effective). Collimation was 14 x 1.2 mm. CT numbers were measured in renal parenchyma and tumor, liver, aorta, and psoas muscle. Image noise was measured on TNE and VNE images. Exclusion of relevant anatomy with the 26-cm field of view detector was quantified with a five-point scale (0 = none, 4 = >75%). Image quality and noise (1 = none, 5 = severe) and acceptability for VNE and TNE images were rated. Effective radiation doses for DE CT and TNE images were calculated. Differences were tested with a Student t test for paired samples. Results: Mean CT numbers (+/- standard deviation) on TNE and VNE images, respectively, for renal parenchyma were 30.8 HU +/- 4.0 and 31.6 HU +/- 7.1, P = .29; liver, 55.8 HU +/- 8.6 and 57.8 HU +/- 10.1, P = .11; aorta, 42.1 HU +/- 4.1 and 43.0 HU +/- 8.8, P = .16; psoas, 47.3 HU +/- 5.6 and 48.1 HU +/- 9.3 HU, P = .38. No exclusion of the contralateral kidney was seen in 50 patients, less than 25% was seen in 43, 25%-50% was seen in 13, and 50%-75% was seen in four. Mean image noise was 1.71 +/- 0.71 for VNE and 1.22 +/- 0.45 for TNE (P < .001); image quality was 1.70 HU +/- 0.72 for VNE and 1.15 HU +/- 0.36 for TNE (P < .0001). In all but three patients radiologists accepted VNE images as replacement for TNE images. Mean effective dose for DE CT scans of the abdomen was 5.21 mSv +/- 1.86 and that for nonenhanced scans was 4.97 mSv +/- 1.43. Mean dose reduction by omitting the TNE scan was 35.05%. Conclusion: In patients with renal masses, DE CT can provide high-quality VNE data sets, which are a reasonable approximation of TNE data sets. Integration of DE scanning into a renal mass protocol will lower radiation exposure by 35%. (C) RSNA, 2009
引用
收藏
页码:433 / 440
页数:8
相关论文
共 16 条
[1]  
[Anonymous], 2004, EUROPEAN GUIDELINES
[2]   Multiphasic renal CT: Comparison of renal mass enhancement during the corticomedullary and nephrographic phases [J].
Birnbaum, BA ;
Jacobs, JE ;
Ramchandani, P .
RADIOLOGY, 1996, 200 (03) :753-758
[3]   QUANTIFICATION OF CALCIUM IN SOLITARY PULMONARY NODULES USING SINGLE-ENERGY AND DUAL-ENERGY CT [J].
CANN, CE ;
GAMSU, G ;
BIRNBERG, FA ;
WEBB, WR .
RADIOLOGY, 1982, 145 (02) :493-496
[4]  
Carmi R, 2005, IEEE NUCL SCI CONF R, P1876
[5]   Abdominal Aorta: Evaluation with Dual-Source Dual-Energy Multidetector CT after Endovascular Repair of Aneurysms-Initial Observations [J].
Chandarana, Hersh ;
Godoy, Myrna C. B. ;
Vlahos, Ioannis ;
Graser, Anno ;
Babb, James ;
Leidecker, Christianne ;
Macari, Michael .
RADIOLOGY, 2008, 249 (02) :692-700
[6]   TISSUE SIGNATURES WITH DUAL-ENERGY COMPUTED-TOMOGRAPHY [J].
DICHIRO, G ;
BROOKS, RA ;
KESSLER, RM ;
JOHNSTON, GS ;
JONES, AE ;
HERDT, JR ;
SHERIDAN, WT .
RADIOLOGY, 1979, 131 (02) :521-523
[7]   First performance evaluation of a dual-source CT (DSCT) system [J].
Flohr, TG ;
McCollough, CH ;
Bruder, H ;
Petersilka, M ;
Gruber, K ;
Süss, C ;
Grasruck, M ;
Stierstorfer, K ;
Krauss, B ;
Raupach, R ;
Primak, AN ;
Küttner, A ;
Achenbach, S ;
Becker, C ;
Kopp, A ;
Ohnesorge, BM .
EUROPEAN RADIOLOGY, 2006, 16 (02) :256-268
[8]   QUANTITATIVE BONE-MINERAL ANALYSIS USING DUAL ENERGY COMPUTED TOMOGRAPHY [J].
GENANT, HK ;
BOYD, D .
INVESTIGATIVE RADIOLOGY, 1977, 12 (06) :545-551
[9]   NON-INVASIVE QUANTITATION OF LIVER IN DOGS WITH HEMOCHROMATOSIS USING DUAL-ENERGY CT-SCANNING [J].
GOLDBERG, HI ;
CANN, CE ;
MOSS, AA ;
OHTO, M ;
BRITO, A ;
FEDERLE, M .
INVESTIGATIVE RADIOLOGY, 1982, 17 (04) :375-380
[10]   Dose reduction and image quality in MDCT colonography using tube current modulation [J].
Graser, A. ;
Wintersperger, B. J. ;
Suess, C. ;
Reiser, M. F. ;
Becker, C. R. .
AMERICAN JOURNAL OF ROENTGENOLOGY, 2006, 187 (03) :695-701